Engineering Papers⌕ Search

Engineering topics

Boutan, C.

Publications and source records attributed to Boutan, C..

ADMX Axion Dark Matter Bounds around 3.3 μ eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine-Fischler-Srednicki-Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultralow noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 μ eV , assuming a standard halo model with a local energy density of 0.45 G e V / cm 3 made up 100% of axions. Published by the American Physical Society 2025

79 ASTRONOMY AND ASTROPHYSICS↗

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonvirialized axion search sensitive to Doppler effects in the Milky Way halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki- Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. Here, we report the results of a non-virialized axion search over the mass range 2.81–3.31 µeV, corresponding to the frequency range 680–800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector’s motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of $\mathscr{O}$(10 -7 )c with 95% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion Dark Matter eXperiment: Run 1A analysis details

The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( 2.66 – 2.81 μ eV in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 μeV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter axion search using a Josephson Traveling wave parametric amplifier

Here, we describe the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in an axion dark matter search. The operation of the JTWPA for a period of about two weeks achieved sensitivity to axion-like particle dark matter with axion–photon couplings above 10 -13 Ge V -1 over a narrow range of axion masses centered around 19.84 µeV by tuning the resonant frequency of the cavity over the frequency range of 4796.7–4799.5 MHz. The JTWPA was operated in the insert of the axion dark matter experiment as part of an independent receiver chain that was attached to a 0.56-l cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

47 OTHER INSTRUMENTATION↗

New Horizons: Scalar and Vector Ultralight Dark Matter

The last decade has seen unprecedented effort in dark matter model building at all mass scales coupled with the design of numerous new detection strategies. Transformative advances in quantum technologies have led to a plethora of new high-precision quantum sensors and dark matter detection strategies for ultralight ($<10\,$eV) bosonic dark matter that can be described by an oscillating classical, largely coherent field. This white paper focuses on searches for wavelike scalar and vector dark matter candidates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Axion Dark Matter Experiment: Detailed design and operations

Axion dark matter experiment ultra-low noise haloscope technology has enabled the successful completion of two science runs (1A and 1B) that looked for dark matter axions in the 2.66–3.1 μeV mass range with Dine–Fischler–Srednicki–Zhitnisky sensitivity. Therefore, it is the most sensitive axion search experiment to date in this mass range. Here, we discuss the technological advances made in the last several years to achieve this sensitivity, which includes the implementation of components, such as the state-of-the-art quantum-noise-limited amplifiers and a dilution refrigerator. Furthermore, we demonstrate the use of a frequency tunable microstrip superconducting quantum interference device amplifier in run 1A, and a Josephson parametric amplifier in run 1B, along with novel analysis tools that characterize the system noise temperature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗