Engineering Papers⌕ Search

Engineering topics

Borgwardt, Tyler Cody

Publications and source records attributed to Borgwardt, Tyler Cody.

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light Output Fitting Software

Light output response of scintillators is crucial to the utilization of organic scintillators as effective tools in radiation detection and measurement. While the response is a continuous distribution, the light output corresponding to the maximum energy deposition is crucial in effectively understanding and simulating a detector. There are a variety of fits derived in literature that will vary for every detector material. The Light Output Response Fitter, or LORF Program is a python script designed to easily and quickly compute and plot fits for a variety of scintillator light output models. It includes a stopping power library constructed from SRIM including Organic Glass, EJ309, EJ301, Stilbene, EJ276, and their deuterated counterparts by default, with the ability for the user to add custom stopping power libraries. The user is also capable of importing the python package and utilizing its in-built functions as appropriate. Uses for this capability include plotting and computing a model with known parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

Neutron Leakage Spectra of the EUCLID Experiment [Abstract]

Integral experiments with sub-critical and critical configurations of special nuclear material are performed in support of nuclear data validation and adjustment. Different nuclear data evaluations may have different values for individual cross sections due to uncertainties in (or lack of) differential experiments, but compensating errors in these data sets can lead to the same k eff results for one application while vastly different for another application. One example of this is 239 Pu, where both ENDF/B-VIII.0 and JEFF-3.3 correctly compute k eff of the Jezebel critical assembly, but the individual contributions from each reaction are vastly different. To help resolve this specific case, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project used machine learning to design a set of experiments to help resolve the compensating errors in 239 Pu. A total of six responses were measured during the experimental campaign, which constrain the data in ways that k eff alone cannot and will be used for adjustment of the nuclear data. One of these responses is the neutron leakage spectrum, which recent work has shown to be useful for constraining the prompt fission neutron spectrum and inelastic scattering. The neutron leakage spectra were measured utilizing a 3 in. right cylinder EJ-301D detector. The measured signal in the detector was deconvoluted using spectrum unfolding techniques, which are presented and compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancements of the nSpec system

For this study, a new characterization of the detector response for the EJ301 liquid scintillator based nSpec system has been conducted at the Los Alamos Neutron Science Center. The new characterization was accomplished in two orders of magnitude less time and with better statistics than the previous characterization. The new and old characterization methods were compared by conducting both types of characterization on two detectors (one EJ301 and one EJ301D). The two methods show consistent results and compare well to results previously published in the literature; however, the results from the characterization of the original nSpec detector show discrepancies that have been identified as being caused by oxygen being absorbed into the detector due to a leak. The new characterized detector response shows improved spectrum unfolding performance than the previous characterization. The cross talk of the detector system was also characterized as a function of incident neutron energy and found to have a negligible impact on spectrum unfolding results. Alternative materials (EJ301D and stilbene) were also characterized in a first step towards an upgraded system. The different materials show little difference in unfolding performance, but the comparison is ongoing. A SiPM based stilbene detector was used to evaluate the use of SiPMs in a future system upgrade. The SiPM provides adequate performance, but the custom SiPM readout results in a much longer pulse width than PMT based systems. The measured light output of the SiPM based stilbene compares well with the results in literature. Future work will look at additional materials (deuterated stilbene and organic glass) and optimizing the SiPM readout to decrease the pulse width.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Active Interrogation of the Snyder Shells using a SEA-7 Betatron

The shielded highly enriched uranium (HEU) problem is one that still needs to be addressed. As a first step towards a solution, the Snyder shells (depleted uranium) were actively interrogated with a SEA-7 betatron in various configurations using an MC15 as a detector. These configurations include masses from 0.55 to 5.1 kg, as well as 5.1 kg in a steel container. A strong electromagnetic field (EMF) background was identified in previous work, but the results in this work show all configurations produce a signal well above the background. An initial simulation capability was developed that produces the expected flux profile from the SEA-7 betatron, but further work needs to be done to determine the magnitude of the flux via a combination of experiment and simulation validation. Depleted uranium generally produces more neutrons than HEU, so additional future work will need to include similar measurements of HEU to confirm similar performance of the technique. Additionally the EMF background needs to be better characterized as a function of distance and angle from the SEA-7 source and mitigation techniques explored.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗