Engineering Papers⌕ Search

Engineering topics

Bond, Evelyn M.

Publications and source records attributed to Bond, Evelyn M..

Neutron-induced capture-to-fission cross section ratio measured at LANSCE

Capture-to-fission cross section ratios are used as an alternative to absolute cross section measurements. This is due to the simplification on the calculations and the reduction of the uncertainties with respect to an absolute measurement of the cross section by eliminating experimental complications like self-absorption, beam/target overlap and non-uniformities. Different capture-to-fission reactions have been measured through the years at the Los Alamos Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL) using the Detector for Advanced Neutron Capture Experiments (DANCE) combined with different fission detectors. Some of these are a Parallel Plate Avalanche Counter (PPAC) to detect fission fragments (FF), and the NEUtron detector array at DANCE (NEUANCE) to detect fission neutrons. As DANCE detects the γ-rays produced in capture and fission reactions, the fission instrument placed inside the DANCE cavity is used to tag the fission γ-rays for background identification and subtraction. Some examples of capture-to-fission ratio measurements performed with DANCE in the last years are the 233 U, 235 U and 239 Pu. The measurement technique, the different setups, and other potential applications of the instruments will be explained.

Nuclear Criticality Safety Program (NCSP)↗

Energy dependence of fission product yields in the second-chance fission region

An extensive dataset of cumulative fission product yields has been generated under a joint collaboration between Los Alamos National Laboratory (LANL), Lawrence Livermore National Laboratory (LLNL), and the Triangle Universities Nuclear Laboratory (TUNL). The energy dependence of the cumulative yield for a select number of high-yield fission products has been measured using quasimonoenergetic neutrons with energies between 5.5 and 11.0 MeV. This is in addition to previously published data covering 0.5–4.5 and 14.8 MeV. The absolute number of fissions was determined during the irradiation period using dual-fission ionization chambers, and the fission products were measured postactivation by whole target γ-ray spectroscopy. Here this paper presents the absolute cumulative fission product yields as a function of incident neutron energy from the neutron-induced fission of 235 U, 238 U, and 239 Pu isotopes at four incident energies in the second-chance fission region and compares them with existing literature values. Corrections relevant to this collaboration's previously published data are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Determining the 193 m Ir/ 192 Ir ratio from high-resolution X-ray measurements

Two pellets of iridium salt were irradiated at the center of the Flattop critical assembly, one at low neutron flux and the other at high flux. After that two counting samples were prepared from each pellet following a given chemical procedure. Measurements of the four counting samples were carried out with two high-resolution silicon drift detectors for over a year. Pulse height spectra of the L→M X-rays from 193 m Ir and 192 Ir were approximated with a Voigt function and the ratio of produced 193 m Ir and 192 Ir nuclei obtained. The 193 m Ir/ 192 Ir ratios from each measured spectrum are compared to identify possible systematic deviations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Avoid Procuring or Storing 2-Propanol in Opaque White, Clear Containers

One of the most important responsibilities chemical owners at Los Alamos National Laboratory (LANL) have is to ensure the safety of the chemicals they own. An important consideration is how chemicals react to their environment. In the case of 2-propanol, a common solvent found in research laboratories used often in manufacturing and analytical processes, it can develop peroxides with exposure to light. 2-Propanol is classified as a Group B (class 3) peroxide-forming solvent. However, there is a dearth of literature that summarizes the risks surrounding peroxide formation in 2-propanol (IPA), leading to a lack of awareness of these hazards in the chemistry community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The new Device for Indirect Capture Experiments on Radionuclides at LANSCE: Efforts on measuring the resonance(s) responsible for the extremely large 88 Zr (n,γ) cross section

The thermal neutron capture cross section of 88 Zr was recently reported to be the second largest in nature with the largest resonance integral measured. Presumably, these very large values are caused by a resonance or resonances very near thermal energy. Determining their energies and widths, and hence the shape of the cross section away from thermal energies,is useful for applications. The short half-life (83.4 days) and associated large background, renders direct measurements of the neutron capture cross section impossible using current techniques. However, it is possible to measure the total neutron cross section, and hence the resonance properties, using the newly commissioned Device for Indirect Capture Experiments on Radionuclides (DICER) at the Los Alamos Neutron Science Center (LANSCE). Transmission measurements are utilized as a surrogate method to perform capture measurements. The 88 Zr needed for a DICER measurement was produced at the Isotope Production Facility (IPF) and cleanly separated from the production target material. A description of the new instrument, efforts and preliminary results on 88 Zr will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Improvements in iridium target chemistry

Abstract We developed and optimized the dissolution and separation chemistry of iridium (Ir) from irradiated Ir pellets and prepared Ir counting samples for analysis by a silicon drift detector. Previous Ir chemistry techniques used on the irradiated Ir pellets are tedious, lengthy, and require extra safety precautions and planning due to the use of perchloric acid in the dissolution step. The dissolution and separations method described in this paper are safer, eliminating the use of perchloric acid, more efficient, and can successfully replace the previous procedure.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Variable energy X-ray fluorescence source

Here we detail the design of a variable energy, x-ray fluorescence source using a low activity (1.8×10 6 dpm) 99 Tc β source that irradiates thin foils. By rotating the source among foils of Ti, Zn, Nb, Ag, and Au, the device produces x rays between 4 and 70 keV at a rate near 1 Hz. When the source is placed in a storage position, the external radiation is non-detectable. The design of the shielding and rotation mechanism permits use in vacuum and at liquid nitrogen temperature. The design is intended for the study of the low energy response to radiation impinging upon Ge detector surfaces. The source will be useful for understanding the detector response in large-scale Ge arrays such as MAJORANA and LEGEND.

47 OTHER INSTRUMENTATION↗