Engineering Papers⌕ Search

Engineering topics

Bolotnikov, A

Publications and source records attributed to Bolotnikov, A.

At least 37 records · Page 2

Crystal Defects in CdZnTe Crystals Grown by the Modified Low-Pressure Bridgman Method

Cadmium Zinc Telluride (CZT) is among the most promising materials for room-temperature X- and gamma-ray detectors. However, crystal defects such as Te inclusions and subgrain boundaries significantly hamper their performances. In this work, we evaluated CZT crystals grown by the modified low-pressure Bridgman technique at the IMEM Institute, Parma. We characterized the crystals by IR microscopy to identify the sizes and concentrations of the Te inclusions, along with high spatial resolution X-ray response mapping to measure the uniformity of their charge-transport properties. In addition, we employed white X-ray beam diffraction topography to analyze their crystalline structure.

36 MATERIALS SCIENCE↗

Point Defects in Pb-, Bi-, and In-Doped CdZnTe Detectors:Deep-Level Transient Spectroscopy (DLTS) Measurements

We studied, by current deep-level transient spectroscopy (I-DLTS), point defects induced in CdZnTe detectors by three dopants: Pb, Bi, and In. Pb-doped CdZnTe detectors have a new acceptor trap at around 0.48 eV. The absence of a V{sub Cd} trap suggests that all Cd vacancies are compensated by Pb interstitials after they form a deep-acceptor complex [[Pb{sub Cd}]{sup +}-V{sub Cd}{sup 2-}]{sup -}. Bi-doped CdZnTe detectors had two distinct traps: a shallow trap at around 36 meV and a deep donor trap at around 0.82 eV. In detectors doped with In, we noted three well-known traps: two acceptor levels at around 0.18 eV (A-centers) and 0.31 eV (V{sub Cd}), and a deep trap at around 1.1 eV.

36 MATERIALS SCIENCE↗

Point Defects in CdZnTe Crystals Grown by Different Techniques

We studied, by current deep-level transient spectroscopy (I-DLTS), point defects in CdZnTe detectors grown by different techniques. We identified 12 different traps with energy levels from 7 meV to 1.1 eV. Although the levels of most of the identified defects were independent of the crystal growth techniques, nevertheless there were some associated differences in the traps energies and densities.

36 MATERIALS SCIENCE↗

Effect of Extended Defects in Planar and Pixelated CdZnTe Detectors

We evaluated a spectroscopy-grade 15 x 15 x 7 mm{sup 3} CdZnTe (CZT) crystal with a high {mu}{tau}-product, > 10{sup -2} cm{sup 2}/V, but impaired by microscopic extended defects, such as walls of dislocations, low-angle and sub-grain boundaries, and Te inclusions. First, we evaluated a planar detector fabricated from this crystal using a Microscale X-ray Detector Mapping (MXDM) technique. Then, we fabricated from the same crystal a pixel detector to study local non-uniformities of the electric field. The measured X-ray response maps confirmed the presence of non-uniformities in the charge transport, and they showed that the global- and local-distortions of the internal E-field correlated to the extended defects and space-charge buildup on the side surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of Te Inclusions in CdZnTe Crystals at Different Temperatures

CdZnTe crystals often exhibit nonuniformities due to the presence of Te inclusions and dislocations. High concentrations of such defects in these crystals generally entail severe charge-trapping, a major problem in ensuring the device's satisfactory performance. In this study, we employed a high-intensity, high-spatial-resolution synchrotron x-ray beam as the ideal tool to generate charges by focusing it over the large Te inclusions, and then observing the carrier's response at room- and at low-temperatures. A high spatial 5-{micro}m resolution raster scan revealed the fine details of the presence of extended defects, like Te inclusions and dislocations in the CdZnTe crystals. A noticeable change was observed in the efficiency of electron charge collection at low temperature (1 C), but it was hardly altered at room-temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlations Between Crystal Defects and Performance of CdZnTe Detectors

Poor crystallinity remains a major problem affecting the availability and cost of CdZnTe (CZT) detectors. Point defects are responsible for small gradual charge loss and correlated with the electron clouds' drift times, which allows electronic correction of the output signals to achieve high spectral-resolution even with large-volume CZT detectors. In contrast, extended defects causes significant charge losses, which typically are uncorrelated, and, thus, result in much greater fluctuations of the output signals that cannot be corrected. Although extended defects do not affect all the interaction events, their fraction rapidly increases with the crystal's thickness and volume. In this paper, we summarize our recent results from testing CZT material and detectors that emphasize the particular roles of two types of extended defects, and their contributions to the device's overall performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An effect of the networks of the subgrain boundaries on spectral responses of thick CdZnTe detectors

CdZnTe (CZT) crystals used for nuclear-radiation detectors often contain high concentrations of subgrain boundaries and networks of poligonized dislocations that can significantly degrade the performance of semiconductor devices. These defects exist in all commercial CZT materials, regardless of their growth techniques and their vendor. We describe our new results from examining such detectors using IR transmission microscopy and white X-ray beam diffraction topography. We emphasize the roles on the devices performances of networks of subgrain boundaries with low dislocation densities, such as poligonized dislocations and mosaic structures. Specifically, we evaluated their effects on the gamma-ray responses of thick, >10 mm, CZT detectors. Our findings set the lower limit on the energy resolution of CZT detectors containing dense networks of subgrain boundaries, and walls of dislocations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing of Kaonetics Devices at BNL

The goal of these measurements was to evaluate whether there is evidence of emission of X-rays, gamma-rays, and neutrons by devices developed by Kaonetics Technologies, Inc. during their operation.

99 GENERAL AND MISCELLANEOUS↗

Thermographic analyses of the growth of Cd1-xZnxTe single crystals

Bulk Cd1-xZnxTe (0<x<0.1) single crystals for gamma-ray detectors are grown mainly from near-stoichiometric melts. We discuss the influence of the thermal pre-history of the melts (superheating, thermo-cycling, and cooling rate) on various physical properties based on our thermographic analyses, electrical conductivity and viscosity measurements. Increasing the Zn content causes non-monotonic dependencies in the quality of the crystals structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cadmium Manganese Telluride (Cd1-xMnxTe): A potential material for room-temperature radiation detectors

Cadmium Manganese Telluride (CdMnTe) recently emerged as a promising material for room-temperature X- and gamma-ray detectors. It offers several potential advantages over CdZnTe. Among them is its optimal tunable band gap ranging from 1.7-2.2 eV, and its relatively low (< 50%) content of Mn compared to that of Zn in CdZnTe that assures this favorable band-gap range. Another important asset is the segregation coefficient of Mn in CdTe that is approximately unity compared to 1.35 for Zn in CdZnTe, so ensuring the homogenous distribution of Mn throughout the ingot; hence, a large-volume stoichiometric yield is attained. However, some materials issues primarily related to the growth process impede the production of large, defect-free single crystals. The high bond-ionicity of CdMnTe entails a higher propensity to crystallize into a hexagonal structure rather than to adopt the expected zinc-blend structure, which is likely to generate twins in the crystals. In addition, bulk defects generate in the as-grown crystals due to the dearth of high-purity Mn, which yields a low-resistivity material. In this presentation, we report on our observations of such material defects in current CdMnTe materials, and our evaluation of its potential as an alternative detector material to the well-known CdZnTe detectors. We characterized the bulk defects of several indium- and vanadium-doped Cd1-xMnxTe crystals by using several advanced techniques, viz., micro-scale mapping, white-beam x-ray diffraction/reflection topography, and chemical etching. Thereafter, we fabricated some detectors from selected CdMnTe crystals, characterized their electrical properties, and tested their performance as room-temperature X- and gamma-ray detectors. Our experimental results indicate that CdMnTe materials could well prove to become a viable alternative in the near future.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extended defects in CdZnTe crystals: Effects on device performance

We explored some unique defects in a batch of cadmium zinc telluride (CdZnTe) crystals, along with dislocations and Te-rich decorated features, revealed by chemical etching. We extensively investigated these distinctive imperfections in the crystals to identify their origin, dimensions, and distribution in the bulk material. We estimated that these features ranged from 50 to 500 {micro}m in diameter, and their depth was about 300 {micro}m. The density of these features ranged between 2 x 10{sup 2} and 1 x 10{sup 3} per cm{sup 3}. We elaborated a model of them and projected their effect on charge collection and spectral response. In addition, we fabricated detectors with these defective crystals and acquired fine details of charge-transport phenomena over the detectors volume using a high-spatial resolution (25 {micro}m) X-ray response mapping technique. We related the results to better understand the defects and their influence on the charge-transport properties of the devices. The role of the defects was identified by correlating their signatures with the findings from our theoretical model and our experimental data.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Effective surface passivation of CdMnTe materials

Passivation is an important process that reduces surface leakage current and its attendant noise. We treated detector-grade large-volume CdMnTe:In samples with an (NH{sub 4})-based passivant, and compared the results with untreated samples by measuring current-voltage characteristics, surface recombination velocity, Raman spectroscopy, and charge-collection mapping. The leakage current of the passivated CdMnTe (CMT) detectors decreased five to ten times, and surface recombination declined five to six times, depending on the passivation conditions applied. We satisfactorily explained these improvements in detector performance as resulting from different passivation layers that were generated by distinct chemical reactions, as determined by the pH of the passivant.

36 MATERIALS SCIENCE↗

Defect levels and thermomigration of Te precipitates in CdZnTe:Pb

Semi-insulating Cd0.9Zn0.1Te:Pb crystals were grown by the vertical Bridgman method. Measurements of the current deep level transient spectroscopy (I-DLTS) revealed three trap levels in this material. Unlike other compensating dopants, CdZnTe:Pb samples do not show any Cd-vacancies defects and A-center levels. We subjected them to temperature-gradient annealing in Cd overpressure at 490–717 1C, and recorded an exponential relationship between the annihilation time of Te precipitates and the annealing temperature. The energy resolution of an annealed CdZnTe:Pb detector, tested using a 137Cs radioactive source, gave an energy resolution of 2.5%.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigations of Cadmium Manganese Telluride Crystals for Room-temperature Radiation Detection

Cadmium manganese telluride (CMT) has high potential as a material for room-temperature nuclear-radiation detectors. We investigated indium-doped CMT crystals taken from the stable growth region of the ingot and compared its characteristics with that from the last-to-freeze region. We employed different techniques, including synchrotron white-beam x-ray topography (SWBXT), current-voltage (I-V) measurement, and low-temperature photoluminescence spectra, and we also assessed their responses as detectors of radiation exposure. The crystal from the stable growth region proved to be superior to that from the last-to-freeze region; it is a single-grain crystal, free of twins, and displayed a resistivity higher by one order of magnitude. The segregation of indium dopant in the ingot might be responsible for its better resistivity. Furthermore, we recorded a good response in the detector fabricated from the crystal taken from the stable growth region; its ({mu}{tau})e value was 2.6 x 10{sup -3} cm{sup 2}/V, which is acceptable for thin detectors, including their application in medicine.

36 MATERIALS SCIENCE↗