Fast wave interferometer for ion density measurement on DIII-D

=A fast wave interferometer (FWI), which can measure ion mass density, has been developed on DIII-D for its use on future fusion reactors, as well as for the study of ion behavior in current plasma devices. The frequency of the fast waves used for the FWI is around 60 MHz, and require antennas and coaxial cables or waveguides, which, unlike traditional mirror-based optical interferometers, are less susceptible to neutron/gamma-ray radiation and are relatively immune to impurity deposition and erosion as well as alignment issues. The bulk ion density evaluated using FWI show good agreement with that derived from CO 2 interferometry within about 15%. When the ion mass density measurement by FWI is combined with an electron density measurement from CO 2 interferometry, Z eff measurements are also enabled and are in agreement with those from visible Bremsstrahlung measurements. Additionally, large-bandwidth FWI measurements clearly resolve 10–100 kHz coherent modes and demonstrate its potential as a core fluctuation diagnostic, sensitive to both magnetic and ion density perturbations.

Instruments & Instrumentation↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗