Engineering Papers⌕ Search

Engineering topics

Bodony, Daniel J.

Publications and source records attributed to Bodony, Daniel J..

Boundary-consistent B-spline filtering schemes and application to high-fidelity simulations of turbulence

A filtering operation, based on B-spline discretizations, is introduced to target weakly growing mesh-scale oscillations that can arise in high-fidelity turbulence simulations. This is a spectral regularization that can be described using the singular values of a banded matrix operator, with the filtering strength set by a scalar- or vector-valued penalty parameter. The penalty parameter can be specified though it can also be advantageously selected to minimize the generalized cross validation (GCV) measure of distance between the pre- and post-filtered solutions. Efficient algorithms are developed to compute both the scalar and vector penalty parameters. The B-spline filter has a sharper localization to high-wavenumber than compact or explicit filters of the same stencil width and is demonstrated for solutions of the Burgers' equation, decaying Burgers' turbulence, and compressible Navier–Stokes turbulent channel flow. Furthermore, these simulations confirm the scheme's numerical stability and ability to narrowly target the high wavenumber components of numerical solutions. An advantage over finite-difference filters is that these B-spline filters are stable on bounded domains and even preserve formal order of accuracy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning-assisted early ignition prediction in a complex flow

Machine learning methods are used to improve the efficiency by which turbulence-resolved simulations predict whether a hydrogen jet in air crossflow will successfully ignite. The flush-mounted jet issues perpendicularly from the wall of a low-speed wind tunnel into a turbulent boundary layer wherein a laser-induced optical breakdown (LIB) hotspot is deposited. A detailed hydrogen chemical mechanism is used to model the radicals and any subsequent chemical reactions. A dielectric-barrier discharge actuator generates body forces and hydrogen radicals near the jet orifice. Here we focus on the success or not of the ignition based on LIB location. A challenge is that definitive determination of this requires long simulations, up to 440 µs after the LIB deposition. This is particularly expensive since multiple simulations are required to find the threshold. To reduce the computational effort, three short-time (91 µs) criteria are proposed, evaluated, and compared: a constructed criterion based on detailed observations of radicals near the stoichiometric surface and two machine learning approaches, each trained on 38 realizations. The constructed criterion provides a low-cost estimate of the ignition boundary that is unambiguous in 45 of the 50 training and test trials, so only 10% of them would need to be simulated longer. The trained neural networks correctly predict outcomes in all cases evaluated, with the more automated procedure—a convolutional neural network (CNN) trained on two-dimensional images—providing the most definitive outcome prediction. From the CNN, a sensitivity analysis is used to determine which kernel features from the two-dimensional input data, as defined by intermediate-layer network weights, are important for identifying ignition.

42 ENGINEERING↗

Actuator selection and placement for localized feedback flow control

The selection and placement of actuators and sensors to control compressible viscous flows is addressed by developing a novel methodology based upon the eigensystem structural sensitivity of the linearized evolution operator appropriate for linear feedback control. Forward and adjoint global modes are used to construct a space of possible perturbations to the linearized operator, which yields a small optimization problem for selecting the parameters that best achieve the control objective, including where they should be placed. The method is demonstrated by informing actuation to suppress amplification of the instabilities in boundary layer separation in a high-subsonic diffuser. Complete stabilization is observed in the separated shear layer for short downstream distances at modest Reynolds number. Higher Reynolds numbers and longer distances are expected to be more challenging to stabilize; here the control informed by the procedure still substantively suppresses amplification of instabilities. It is also demonstrated that more complex actuator–sensor selections may not yield superior controllers.

Mechanics↗

Adjoint-based sensitivity analysis of localized ignition in a non-premixed hydrogen-air mixing layer

A space-time discrete-adjoint method recently developed for high-fidelity compressible turbulence simulations is extended to chemically-reacting mixtures for the purpose of measuring sensitivity of localized ignition in a non-premixed hydrogen-air mixing layer. The ignition source is modeled as a source in the energy equation, which introduces several parameters that need to be chosen with care. Because ignition is inherently discontinuous in parameter space (i.e., it succeeds or fails after some period), the resulting gradients in modeling parameters are ill-defined near its threshold. To this end, a cost functional is designed to provide short-time sensitivity in concert with an indicator function that informs whether or not successful ignition has occurred. The corresponding sensitivity is used in a line-search algorithm to identify a point on the ignition boundary in high-dimensional parameter space (7 dimensional in our 7-parameter demonstration). This is used to quantify the relative importance of parameters on ignition.

Capecelatro, Jesse↗

A practical discrete-adjoint method for high-fidelity compressible turbulence simulations

Methods and computing hardware advances have enabled accurate predictions of complex compressible turbulence phenomena, such as the generation of jet noise that motivates the present effort. However, limited understanding of underlying physical mechanisms restricts the utility of such predictions since they do not, by themselves, indicate a route to design improvements. Gradient-based optimization using adjoints can circumvent the flow complexity to guide designs, though this is predicated on the availability of a sufficiently accurate solution of the forward and adjoint systems. These are challenging to obtain, since both the chaotic character of the turbulence and the typical use of discretizations near their resolution limits in order to efficiently represent its smaller scales will amplify any approximation errors made in the adjoint formulation. Formulating a practical exact adjoint that avoids such errors is especially challenging if it is to be compatible with state-of-the-art simulation methods used for the turbulent flow itself. Automatic differentiation (AD) can provide code to calculate a nominally exact adjoint, but existing general-purpose AD codes are inefficient to the point of being prohibitive for large-scale turbulence simulations. Here, we analyze the compressible flow equations as discretized using the same high-order workhorse methods used for many high-fidelity compressible turbulence simulations, and formulate a practical space–time discrete-adjoint method without changing the basic discretization. A key step is the definition of a particular discrete analog of the continuous norm that defines our cost functional; our selection leads directly to an efficient Runge–Kutta-like scheme, though it would be just first-order accurate if used outside the adjoint formulation for time integration, with finite-difference spatial operators for the adjoint system. Its computational cost only modestly exceeds that of the flow equations. We confirm that its accuracy is limited by computing precision, and we demonstrate it on the aeroacoustic control of a mixing layer with a challengingly broad range of turbulence scales. For comparison, the error from a corresponding discretization of the continuous-adjoint equations is quantified to potentially explain its limited success in past efforts to control jet noise. The differences are illuminating: the continuous-adjoint is shown to suffer from exponential error growth in (reverse) time even for the best-resolved largest turbulence scales. Implications for jet noise reduction and turbulence control in general are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗