High-resolution spectroscopy of gaseous 83m Kr conversion electrons with the KATRIN experiment

Abstract In this work, we present the first spectroscopic measurements of conversion electrons originating from the decay of metastable gaseous 83m Kr with the Karlsruhe Tritium Neutrino (KATRIN) experiment. The obtained results represent one of the major commissioning milestones for the subsequent direct neutrino mass measurement with KATRIN. The successful campaign demonstrates the functionalities of the KATRIN beamline. Precise measurement of the narrow K-32, L 3 -32, and N 2,3 -32 conversion electron lines allowed to verify the eV-scale energy resolution of the KATRIN main spectrometer necessary for competitive measurement of the absolute neutrino mass scale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design improvements to cables and connectors in the Majorana Demonstrator

The Majorana Demonstrator is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium p-type point contact detectors totaling 44.1 kg, located at the 4850 level of the Sanford Underground Research Facility in Lead, South Dakota, USA. The Demonstrator uses custom high voltage cables to bias the detectors, as well as custom signal cables and connectors to read out the charge deposited at the point contact of each detector. These low-mass cables and connectors must meet stringent radio purity requirements while being subjected to thermal and mechanical stress. A number of issues have been identified with the currently installed cables and connectors. An improved set of cables and connectors for the Majorana Demonstrator are being developed with the aim of increasing their overall reliability and connectivity. In conclusion, we will discuss some of the issues encountered with the current cables and connectors as well as our improved designs and their initial performance.

42 ENGINEERING↗

Spectral analysis for the M AJORNA D EMONSTRATOR experiment

The M AJORNA D EMONSTRATOR is an experiment constructed to search for neutrinoless double-beta decays in germanium-76 and to demonstrate the feasibility to deploy a ton-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76 Ge-enriched germanium detectors totaling 44.1kg (29.7kg enriched detectors), located at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data taken with this setup since summer 2015 at different construction stages of the experiment show a clear reduction of the observed background index around the ROI for 0$νββ$- decay search due to improvements in shielding. We discuss the statistical approaches to search for a 0$νββ$-signal and derive the physics sensitivity for an expected exposure of 10kg y from enriched detectors using a profile likelihood based hypothesis test in combination with toy Monte Carlo data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress Toward A $2νββ$ Measurement For The M AJORNA D EMONSTRATOR

The M AJORNA D EMONSTRATOR is a 76 Ge-based neutrinoless double-beta decay (0 νββ ) experiment. Staged at the 4850 ft level of the Sanford Underground Research Facility, the D EMONSTRATOR operates an array of high-purity p-type point contact Ge detectors deployed within a graded passive shield and an active muon veto system. The present work concerns the two-neutrino double-beta decay mode (2 νββ ) of 76 Ge. For Ge detectors, having superior energy resolution (0.1%), this mode poses negligible background to the 0 νββ mode, even for a ton-scale experiment. However, the measurement of the 2 νββ mode allows for careful systematics checks of active detector mass, enrichment fraction, and pulse shape discrimination cuts related to both the 0 νββ and 2 νββ decay modes. A precision measurement of the 2 νββ shape also allows searches for spectral distortions, possibly indicative of new physics, including 0 νββχ . Work is underway to construct a full experimental background model enabling a Bayesian fit to the measured energy spectrum and extraction of a precise 2 νββ spectrum and half-life.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent results from the Majorana Demonstrator

The MAJORANA DEMONSTRATOR is an experiment constructed to search for Neutrinoless double-beta decay in 76Ge and to demonstrate the feasibility to deploy a large-scale experiment in a phased and modular fashion. It consists of two modular arrays of natural and 76Ge-enriched germanium detectors totalling 44.1 kg, operating on the 4850’ level of the Sanford Underground Research Facility in Lead, South Dakota, USA. Data acquisition in the commissioning phase began in June 2015, followed by data acquisition with the full detector array in August 2016. The ultralow background and record energy resolution achieved by the MAJORANA DEMONSTRATOR enable a sensitive neutrinoless double-beta decay search, as well as additional searches for physics beyond the Standard Model. I will discuss the design elements that enable these searches, along with our latest results, focusing on the neutrinoless double-beta decay search. I will also discuss the current status and the future plans of the MAJORANA DEMONSTRATOR, as well as the plans for a future tonne-scale 76Ge experiment.

Myslik, Jordan W.↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

The Majorana Demonstrator Status and Preliminary Results

The MAJORANA Collaboration is using an array of high-purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. Searches for neutrinoless double-beta decay are understood to be the only viable experimental method for testing the Majorana nature of the neutrino. Observation of this decay would imply violation of lepton number, that neutrinos are Majorana in nature, and provide information on the neutrino mass. The MAJORANA DEMONSTRATOR comprises 44.1 kg of p-type point-contact Ge detectors (29.7 kg enriched in 76 Ge) surrounded by a low-background shield system. The experiment achieved a high efficiency of converting raw Ge material to detectors and an unprecedented detector energy resolution of 2.5 keV FWHM at Q ββ . The MAJORANA collaboration began taking physics data in 2016. Here, this paper summarizes key construction aspects of the Demonstrator and shows preliminary results from initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Recent Results from the Majorana Demonstrator

The MAJORANA Collaboration has completed construction and is now operating an array of high purity Ge detectors searching for neutrinoless double-beta decay ($0\nu\beta\beta$) in $^{76}$Ge. The array, known as the MAJORANA DEMONSTRATOR, is comprised of 44 kg of Ge detectors (30 kg enriched to 88% in $^{76}$Ge) installed in an ultra-low background compact shield at the Sanford Underground Research Facility in Lead, South Dakota. The primary goal of the DEMONSTRATOR is to establish a low-background design that can be scaled to a next-generation tonne-scale experiment. This work reports initial background levels in the $0\nu\beta\beta$ region of interest. Also presented are recent physics results leveraging P-type point-contact detectors with sub-keV energy thresholds to search for physics beyond the Standard Model; first results from searches for bosonic dark matter, solar axions, Pauli exclusion principle violation, and electron decay have been published. Finally, this work discusses the proposed tonne-scale $^{76}$Ge $0\nu\beta\beta$ LEGEND experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First transmission of electrons and ions through the KATRIN beamline

The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium β-decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous 83m Kr was injected into the KATRIN source section, and a condensed 83m Kr source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. In conclusion, we have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Neutrinoless Double-ß Decay in 76Ge with the Majorana Demonstrator

The Majorana Collaboration is operating an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76Ge. The Majorana Demonstrator is comprised of 44.8 kg (29.7 kg enriched in 76Ge) of Ge detectors in total, split between two modules contained in a low background shield at the Sanford Underground Research Facility in Lead, South Dakota. Here we present results from data taken during construction, commissioning, and the start of full operations. Given the unprecedented energy resolution at Q of 2.5 keV FWHM and the very low background with no observed candidate events in 10 kg yr of enriched Ge exposure, we find a lower limit on the half-life of 1:9 x 1025 yr (90% CL). This result constrains the effective Majorana neutrino mass to below 250 to 550 meV, depending on the matrix elements used. In our experimental configuration with the lowest background, the background is 4:0 +3:1(superscript) -2:5 (subscript) counts/(FWHM t yr) at 68% CL.

Aalseth, Craig E.↗

Contamination control and assay results for the Majorana Demonstrator ultra clean components

The Majorana Demonstrator is a neutrinoless double beta decay experiment utilizing enriched Ge-76 detectors in 2 separate modules inside of a common solid shield at the Sanford Underground Research Facility. The Demonstrator has utilized world leading assay sensitivities to develop clean materials and processes for producing ultra-pure copper and plastic components. This experiment is now operating, and initial data provide new insights into the success of cleaning and processing. Post production copper assays after the completion of Module 1 showed an increase in U and Th contamination in finished parts compared to starting bulk material. A revised cleaning method and additional round of surface contamination studies prior to Module 2 construction have provided evidence that more rigorous process control can reduce surface contamination. In conclusion, this article describes the assay results and discuss further studies to take advantage of assay capabilities for the purpose of maintaining ultra clean fabrication and process design.

36 MATERIALS SCIENCE↗

Low background materials and fabrication techniques for cables and connectors in the Majorana Demonstrator

Here, the Majorana Collaboration is searching for the neutrinoless double-beta decay of the nucleus 76 Ge. The Majorana Demonstrator is an array of germanium detectors deployed with the aim of implementing background reduction techniques suitable for a tonne scale 76 Ge-based search (the LEGEND collaboration). In the Demonstrator, germanium detectors operate in an ultra-pure vacuum cryostat at 80 K. One special challenge of an ultra-pure environment is to develop reliable cables, connectors, and electronics that do not significantly contribute to the radioactive background of the experiment. This paper highlights the experimental requirements and how these requirements were met for the Majorana Demonstrator, including plans to upgrade the wiring for higher reliability in the summer of 2018. Also described are requirements for LEGEND R&D efforts underway to meet these additional requirements

74 ATOMIC AND MOLECULAR PHYSICS↗

The status and initial results of the Majorana demonstrator experiment

Neutrinoless double-beta decay searches play a major role in determining the nature of neutrinos, the existence of a lepton violating process, and the effective Majorana neutrino mass. The Majorana Collaboration assembled an array of high purity Ge detectors to search for neutrinoless double-beta decay in 76 Ge. The Majorana Demonstrator is comprised of 44.1 kg (29.7 kg enriched in 76 Ge) of Ge detectors divided between two modules contained in a low-background shield at the Sanford Underground Research Facility in Lead, South Dakota, USA. The initial goals of the Demonstrator are to establish the required background and scalability of a Ge-based next-generation ton-scale experiment. Following a commissioning run that started in 2015, the first detector module started low-background data production in early 2016. The second detector module was added in August 2016 to begin operation of the entire array. Lastly, we discuss results of the initial physics runs, as well as the status and physics reach of the full Majorana Demonstrator experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The large enriched germanium experiment for neutrinoless double beta decay (LEGEND)

We report the observation of neutrinoless double-beta decay (0νββ) would show that lepton number is violated, reveal that neu-trinos are Majorana particles, and provide information on neutrino mass. A discovery-capable experiment covering the inverted ordering region, with effective Majorana neutrino masses of 15 - 50 meV, will require a tonne-scale experiment with excellent energy resolution and extremely low backgrounds, at the level of ~0.1 count /(FWHM·t·yr) in the region of the signal. The current generation 76 Ge experiments GERDA and the Majorana Demonstrator, utilizing high purity Germanium detectors with an intrinsic energy resolution of 0.12%, have achieved the lowest backgrounds by over an order of magnitude in the 0νββ signal region of all 0νββ experiments. Building on this success, the LEGEND collaboration has been formed to pursue a tonne-scale 76 Ge experiment. Lastly, the collaboration aims to develop a phased 0νββ experimental program with discovery potential at a half-life approaching or at 10 28 years, using existing resources as appropriate to expedite physics results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗