Engineering PapersSearch

Engineering topics

Biswas, A.

Publications and source records attributed to Biswas, A..

At least 19 records

Mars Mission Scenario: Data Volume and PDT Notes

Objectives of this work are: (1) Investigate methods for quantifying the value of interoperability for deep space missions: A network of optical receive stations Each one potentially owned by a different space agency. Reduces overall cost to any individual agency Provides geographically diverse locations to mitigate weather problems (clouds, wind, rain, dust, etc.) (2) Metrics: a. Total data volume returned over mission duration b. Percent data transferred (PDT) or something similar.

deep space optical communications

Overview and Status of the Lunar Laser Communication Demonstration

The Lunar Laser Communication Demonstration (LLCD), a project being undertaken by MIT Lincoln Laboratory, NASA's Goddard Space Flight Center, and the Jet Propulsion Laboratory, will be NASA's first attempt to demonstrate optical communications between a lunar orbiting spacecraft and Earth-based ground receivers. The LLCD space terminal will be flown on the Lunar Atmosphere and Dust Environment Explorer (LADEE) spacecraft, presently scheduled to launch in 2013. LLCD will demonstrate downlink optical communications at rates up to 620 Mbps, uplink optical communications at rates up to 20 Mbps, and two-way time-of-flight measurements with the potential to perform ranging with sub-centimeter accuracy. We describe the objectives of the LLCD program, key technologies employed in the space and ground terminals, and show the status of development of the several systems.

deep space communications

Deep-Space Optical Terminals

We eport on engineering trades that led to the conceptual design of a laser communications terminal for spacecraft probing Mars. The flight terminal, the ground receiver and the ground transmitter subsystems are described. The flight terminal point design has 0.25 Gb/s downlink data-rate capability from the Mars close distance (0.42 AU). Capability for uplink data-rate of 0.3 Mb/s and ranging with 30 cm precision are also addressed.

laser communications

A Study of an Optical Lunar Surface Communications Network with High Bandwidth Direct to Earth Link

A lunar surface systems study explores the application of optical communications to support a high bandwidth data link from a lunar relay satellite and from fixed lunar assets. The results show that existing 1-m ground stations could provide more than 99% coverage of the lunar terminal at 100Mb/s data rates from a lunar relay satellite and in excess of 200Mb/s from a fixed terminal on the lunar surface. We have looked at the effects of the lunar regolith and its removal on optical samples. Our results indicate that under repeated dust removal episodes sapphire rather than fused silica would be a more durable material for optical surfaces. Disruption tolerant network protocols can minimize the data loss due to link dropouts. We report on the preliminary results of the DTN protocol implemented over the optical carrier.

lunar optical communications

A Study of an Optical Lunar Surface Communications Network with High Bandwidth Direct to Earth Link

Analyzed optical DTE (direct to earth) and lunar relay satellite link analyses, greater than 200 Mbps downlink to 1‐m Earth receiver and greater than 1 Mbps uplink achieved with mobile 5‐cm lunar transceiver, greater than 1Gbps downlink and greater than 10 Mpbs uplink achieved with 10‐cm stationary lunar transceiver, MITLL (MIT Lincoln Laboratory) 2013 LLCD (Lunar Laser Communications Demonstration) plans to demonstrate 622 Mbps downlink with 20 Mbps uplink between lunar orbiter and ground station; Identified top five technology challenges to deploying lunar optical network, Performed preliminary experiments on two of challenges: (i) lunar dust removal and (ii)DTN over optical carrier, Exploring opportunities to evaluate DTN (delay-tolerant networking) over optical link in a multi‐node network e.g. Desert RATS.

lunar surface system

Deep-Space Optical Terminals (DOT)

A conceptual design study titled Deep-Space Optical Terminals was recently completed for an optical communication technology demonstration from Mars in the 2018 time frame. We report on engineering trades for the entire system, and for individual subsystems including the flight terminal, the ground receiver and the ground transmitter. A point design is described to meet the requirement for greater than 0.25 Gb/s downlink from the nearest distance to Mars of 0.42 AU with a maximum mass and power allocation of 40 kg and 110 W. Furthermore, the concept design addresses link closure at the farthest Mars range of 2.7 AU. Maximum uplink data-rate of 0.3 Mb/s and ranging with 30 cm precision are also addressed.

optical communications

Data Products for the OCTL to OICETS Optical Link Experiment

JPL has developed a series of software and hardware tools to analyze and record data from a 50Mb/s down and 2 Mb/s up bi-directional optical link with the LUCE terminal onboard the LEO OICETS satellite. This paper presents the data products for this experiment including the system architecture and analysis of the actual data received.

optical communications

Deep space optical communications link availability and data volume

Optical links from a spacecraft at planetary distance to a ground-based receiver presume a cloud free line of site (CFLOS). Future ground-based optical reeiving networks, should they be implemented, will rely on site diversity of could cover to increase link availability.

optical communications

Laboratory Characterization and Modeling of a Near-Infrared Enhanced Photomultiplier Tube

The photon-starved channel for optical communications from deep space requires the development of detector technology that can achieve photon-counting sensitivities with high bandwidth. In this article, a near-infrared enhanced photomultiplier tube (PMT) with a quantum e.ciency of 0.08 at a 1.06- m wavelength is characterized in the laboratory. A Polya distribution model is used to compute the probability distribution function of the emitted secondary photoelectrons from the PMT. The model is compared with measured pulse-height distributions with reasonable agreement. The model accounts for realistic device parameters, such as the individual dynode stage gains and a shape parameter that is representative of the spatial uniformity of response across the photocathode and dynodes. Bit-error rate (BER) measurements also are presented for 4- and 8-pulse-position modulation (PPM) modulation schemes with data rates of 20 to 30 Mb/s. A BER of 10-2 is obtained for a mean of 8 detected photons.

Biswas, A.

Mountain-Top-to-Mountain-Top Optical Link Demonstration

A mountain-top-to-mountain-top optical communications demonstration was conducted between the JPL Table Mountain Facility (TMF), Wrightwood, California, and Strawberry Peak (SP), Lake Arrowhead, California, during the months of August and September of 2000. The link was nearly horizontal at an altitude of 2 km and spanned a range of 46.8 km. A 780-nm multibeam beacon broadcast from TMF was received by the JPL Optical Communications Demonstrator (OCD) located at SP. The received beacon was utilized as a pointing reference to retransmit an 852-nm communications laser beam, modulated at 400 Mb/s by a PN7 pseudo-random bit stream (PRBS) sequence. The long atmospheric path resulted in atmospheric-turbulence-induced angle-of-arrival fluctuations of the beacon at the OCD aperture. A .ne-steering control loop was used to track the resulting beacon centroid motion and update the pointing of the communications laser beam transmitted from SP to TMF. Fried parameters, or r0, inferred from focal spot sizes received at SP were 4 to 5 cm whereas, using the spot sizes received at TMF, they were 2 to 3 cm. In both cases, theory predicts larger r0 values. The predicted angle-of-arrival fluctuations compare well with measured rms displacements exhibited by the focal spots at either end of the link. An uncompensated error of ~1.1 rad in the x-axis and ~2 rad in the y-axis was obtained using centroid data logged by the OCD. Average bit-error rates of 10-5 were recorded for extended periods of time. An atmospheric coherence length r0 of 3 to 5 cm was inferred using the focal-plane spot size measured on the CCD tracking sensor and compared to a predicted value of 5 to 7 cm using reasonable atmospheric models. The irradiance bounds required for the CCD tracking sensor to perform centroiding was found to range from 2000 to 3000 integrated pixel counts, although a more reliable range was 600 to 3000, indicating a dynamic range of 6 to 11 dB. The motion of the spot on the focal plane was also recorded and yielded rms angle-of-arrival-induced focal-plane displacement of 9 to 11 m, compared to a predicted value of 7.8 to 11 m. The irradiance measurements made with the OCD clearly indicate that best tracking performance is obtained when the mean received signal is 2000 to 2200 counts. The best tracking performance resulted in an rms uncompensated error of 1.1 rad. The uncompensated error appeared to increase with either an increase or decrease in mean beacon-signal level. The rms uncompensated error determined by deriving the beacon displacement power spectral density from the beacon centroid-versustime data and the rejection function of the control loop yielded a higher value of 3.4 rad.

Biswas, A.

Mountain-Top-to-Mountain-Top Optical Link Demonstration

A mountain-top-to-mountain-top optical link was demonstrated between JPL's Table Mountain Facility (TMF), Wrightwood, California, and Strawberry Peak (SP), Lake Arrowhead, California, during the months of June, August, and September of 2000. The bidirectional laser link was nearly horizontal at an altitude of 2 km and spanned a range of 46.8 km. The 780-nm beacon laser transmitted from TMF comprised eight co-propagating mutually incoherent laser beams. The normalized variance or scintillation index (SI) of the individual beacon lasers measured by recording the signal received through 8.50-cm-diameter spotting telescopes on three different nights (June 28-30, 2000) was 1.05 +/- 0.2, 1.76 +/- 0.6, and 0.96 +/- 0.24, respectively. These measurements agreed with values predicted by a heuristic model. The SI of the signal received at SP was found to decrease progressively with an increasing number of beams, and a factor of 3 to 3.5 reduction was achieved for all eight beams. The beam divergence determined by mapping out the point spread function of a few of the individual laser footprints received at SP was 85 to 150 microrad, compared to a design goal of 120 microrad. The 852-nm communications laser beam received at TMF through a 60-cm-diameter telescope on the nights of August 4 and September 14 and 15, 2000, yielded SI values of 0.23 +/- 0.04, 0.32 +/- 0.01, and 0.49 +/- 0.18, respectively, where the reduction was attributed to aperture averaging. The probability distribution functions of the received signal at either end, mitigated by multi-beam averaging in one direction and by aperture averaging in the other direction, displayed lognormal behavior. Consequently, the measured fade statistics showed good agreement with a lognormal model.

Biswas, A.