Simple, accurate analog divider for low divisor values
Electronic analog divider circuit employs, over certain range, current-exponential voltage characteristics of diode to obtain better accuracy at low denominator values.
Engineering topics
Publications and source records attributed to Birchenough, A. G..
Electronic analog divider circuit employs, over certain range, current-exponential voltage characteristics of diode to obtain better accuracy at low denominator values.
Advantage is taken of the current-exponential voltage characteristic of a diode over a certain range whereby the incremental impedance across the diode is inversely proportional to the current through the diode. Accordingly, a divider circuit employs a bias current through the diode proportional to the desired denominator and applies an incremental current to the diode proportional to the numerator. The incremental voltage across the diode is proportional to the quotient.
Process results in long-duration sparks which allow leaner, cleaner combustion. Procedure is not limited by available energy-storage devices and can produce continuous spark of as long duration as desired for optimum engine operation and pollution reduction. System can be modified to operate on engines not using distributor points and can be used with conventional Kettering ignitions.
System has speed control accuracy within approximately 0.001 percent. Accuracy is limited only by crystal reference oscillator; however, effect is negligible on original system stability and transient response. Design can be adapted to other systems and provides compromise between either fully digital or fully analog systems.
A digital speed control that can be combined with a proportional analog controller is described. The stability and transient response of the analog controller were retained and combined with the long-term accuracy of a crystal-controlled integral controller. A relatively simple circuit was developed by using phase-locked-loop techniques and total error storage. The integral digital controller will maintain speed control accuracy equal to that of the crystal reference oscillator.
The design theory and performance of a breadboard of the proposed Mini-Brayton electrical control system is presented. The Mini-Brayton is a nuclear isotope powered dynamic power conversion system. Testing was performed with an electronic simulation of a turbine alternator. Data on the voltage regulation, speed control, power consumption, reliability and transient response are presented for the breadboard.
A modular approach for aerospace electrical systems has been developed, using lightweight high efficiency pulse width modulation techniques. With the modular approach, a required system is obtained by paralleling modules. The modular system includes the inverters and converters, a paralleling system, and an automatic control and fault-sensing protection system with a visual annunciator. The output is 150 V dc, or a low distortion three phase sine wave at 120 V, 400 Hz. Input power is unregulated 56 V dc. Each module is rated 2.5 kW or 3.6 kVA at 0.7 power factor.
A control and protection system was developed for use with a paralleled 2.5-kWe-per-module static inverter-converter system. The control and protection system senses internal and external fault parameters such as voltage, frequency, current, and paralleling current unbalance. A logic system controls contactors to isolate defective power conditioners or loads. The system sequences contactor operation to automatically control parallel operation, startup, and fault isolation. Transient overload protection and fault checking sequences are included. The operation and performance of a control and protection system, with detailed circuit descriptions, are presented.
As part of a modular inverter-converter development program, control techniques were developed to provide load sharing among paralleled inverters or converters. An analysis of the requirements of paralleling circuits and a discussion of the circuits developed and their performance are included in this report. The current sharing was within 5.6 percent of rated-load current for the ac modules and 7.4 percent for the dc modules for an initial output voltage unbalance of 5 volts.
Pulse-width-modulated inverter and converter modules are being developed for modular aerospace electrical power systems. The modules, rate 2.5 kilowatts per module and 10-minute - 150-percent overload, operate from 56 volts dc. The converter module provides two output voltages: a nominal link voltage of 200 volts dc when used with the inverter, and 150 volts dc to a load bus when used separately. The inverter module output is 400-hertz, sinusoidal, three-phase, 120/208 volts. Tests of breadboard models with standard parts and integrated circuits show rated power efficiencies of 71.4 and 85.1 percent and voltage regulation of 5 and 3.1 percent for inverter and converter modules, respectively. Sine-wave output distortion is 0.74 percent.
The square-wave SCR inverter that was designed, built, and tested includes a circuit to turn off the inverter in case of commutation failure. The basic power stage is a complementary impulse-commutated parallel inverter consisting of only six components. The 400-watt breadboard was tested while operating at + or - 28 volts, and it had a peak efficiency of 95.5 percent at 60 hertz and 91.7 percent at 400 hertz. The voltage regulation for a fixed input was 3 percent at 60 hertz. An analysis of the operation and design information is included.
The design of a three-phase, 400-Hz, 15-kVA static inverter for motor-starting the 2- to 15-kWe Brayton electrical space power system is described. The inverter operates from a nominal 56-V dc source to provide a 28-V, rms, quasi-square-wave output. The inverter is capable of supplying a 200-A peak current. Integrated circuitry is used to generate the three-phase, 400-Hz reference signals. Performance data for a drive stage that improves switching speed and provides efficient operation over a range of output current and drive supply voltage are presented. A transformerless, transistor output stage is used.
Input impedances of several hundred megohms and input capacitances of less than one picofarad are achieved with a conventional unity gain are buffer amplifier modified by addition of positive feedback. The circuit is stable over a temperature range of 25 to 70 deg C.
Performance evaluation of Brayton space power system 400-hertz inverters
Mercury-column electrochemical coulometer is a linear ampere-hour integrating device consisting of a sealed glass tube containing two columns of mercury separated by a gap containing an electrolyte. The drive circuit uses operational amplifier techniques to match nonlinear charge-discharge characteristics of an alkaline battery.
Mercury column electrochemical coulometer as ampere-hour type of state-of-charge indicator for secondary batteries in space power applications
Mercury electrochemical coulometer as battery state of charge indicator
Vibration tests on mercury column coulometer