Visual Brick model authoring tool for building metadata standardization

In this study, the Brick ontology is a unified semantic metadata standard for building assets and their relationships, serving as a key enabler for effective interoperability and automation of building systems and analytics. However, creating a Brick model, in other words, standard semantic metadata based on the Brick ontology for a building dataset, can be a complex task. This paper presents two case studies of the creation of Brick models for real-world residential and commercial building datasets, highlighting the challenges during the Brick model creation process. Additionally, the paper introduces VizBrick, an interactive authoring tool for creating semantic building metadata. VizBrick facilitates the creation of Brick models by providing an intuitive visual interface and interactive capabilities, such as keyword search, automatic mapping suggestions, and recommendations. The use of VizBrick is shown to significantly reduce the time and effort required during the Brick model creation process.

42 ENGINEERING↗

Interface gasket for building envelope

A gasket assembly for attaching a window to a panel opening includes an inner frame, an outer frame, and an elastic material connecting the inner frame to the outer frame. The elastic material extends contiguously and circumferentially to couple the outer frame to the inner frame. The outer frame and inner frame can include gap flanges and the elastic material can include opposing lateral side portions. The gap flanges are embedded in the lateral side portions of the elastic material. The outer frame includes connecting structure for coupling of the outer frame to the panel opening. The inner frame includes a connecting structure for coupling of the gasket assembly to the window. The gasket assembly is configured to support the window in the panel opening and form a seal between the panel opening and the window. A method of making a gasket assembly is also disclosed.

Aaron, Adam M.↗

Performance Assessment of the Overall Building Envelope Thermal Performance—Building Envelope Performance (BEP) Metric

Today, to describe the thermal performance of the building envelope and its components we use a variation of metrics; such as, R-value, ACH (air exchange rate per hour), SHGC (solar heat gain coefficient) of windows, U-factor etc. None of these performance indicators is meant to represent the overall thermal performance. In this paper, such a metric is introduced, the BEP (building envelope performance) value. Unlike the thermal resistance, typically expressed as an R-value, the BEP-value considers additional elements of heat transfer that affect the energy demand of the building because of exterior and interior (solar) thermal loads: conductive and radiant heat transfer, and air infiltration. To demonstrate BEP’s utility, validation studies were carried out by comparing the BEP-value to theoretical results using whole building energy simulation tools such as EnergyPlus and WUFI Plus. Results show that BEP calculations are comparable to calculations made using these simulation tools and that unlike other similar metrics, the BEP-value accounts for all heat transfer mechanisms that are relevant for the overall energy performance of the building envelope. The BEP-value thus allows comparing envelopes of buildings with different use types in a fair and realistic manner.

42 ENGINEERING↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

Impacts of the morphology of new neighborhoods on microclimate and building energy

In anticipation of emerging global urbanization and consequent increases in energy use and carbon dioxide emissions, better understanding and quantification of climate effects on energy use in cities are needed, requiring coordinated research into large-scale, regional, and microclimate impacts to and from the city structure. The methodology described here addresses this need by (1) demonstrating a process for creating and testing example morphologies for new neighborhoods for their impact on local and regional meteorology within a two-way-coupled four-domain nested mesoscale weather model (6 km horizontal resolution outer domain, 90 m horizontal innermost domain) and (2) allocating resulting building-level meteorological profiles to each building in a neighborhood for parallel computation of building-by-building energy use. Our Chicago Loop test case shows that the morphology of even a small new added development to a neighborhood affects not only its own microclimate, but also the microclimate of the original neighborhood to which the development was added, and that these changes in microclimate affect both neighborhoods’ building energy use. Furthermore, this method represents an important step toward quantifying and analyzing the relationships among climatic conditions, urban morphology, and energy use and using these relationships to inform energy-efficient urban development and planning.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling the Impact of Flexible CHP on the Future Electric Grid In California

Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States. Typically fueled with natural gas, a CHP system combines a prime mover (such as a reciprocating engine) with a generator and heat recovery equipment, allowing operation at very high efficiencies (65–85%). Traditionally, CHP systems have been configured to serve local electrical and thermal loads at the sites where they are deployed. Units are sized to ensure a high capacity factor for the equipment, and the electricity generated tends to be used on site. CHP units in the United States already generate over 12% of the nation’s electricity. However, CHP’s potential benefits could be much greater if power generated could be used beyond the site, because the analysis was performed under the assumption that sites could use all the thermal output. Analysis of a few key sectors confirmed that this assumption is valid (for more information, see Appendix E). Those benefits could include improved grid reliability and resilience, as well as lower-cost options for providing energy and other grid services. The potential benefits also align well with grid modernization objectives, as shown in Combined heat and power (CHP) systems provide electricity and process heat at more than 4,400 industrial and commercial facilities across the United States., and greater electrification of loads, driven by carbon reduction priorities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Estimating the Energy, Economic, and Durability Benefits of Installing an Air Barrier System in Commercial Buildings

Uncontrolled heat, air, and moisture transfer through the building enclosure has a significant impact on energy usage, comfort, indoor air quality, and building enclosure durability. Air leakage in commercial buildings in the U.S. accounts for about one quad (one quadrillion Btu) of energy annually, costing approximately $10 billion. As the thermal resistance of commercial building enclosures continues to improve, the relative contribution of air leakage to heating and cooling loads is increasing. A wide variety of air barrier technologies and construction practices to reduce the air leakage in buildings are available to the architect and designer. To promote more energy-efficient and durable building enclosure design, advances in easy-to-use tools for determining the impact of air leakage are needed. Oak Ridge National Laboratory (ORNL), the Air Barrier Association of America (ABAA), and the National Institute of Standards and Technology (NIST) partnered to develop an online calculator that estimates the potential energy, cost savings (due to energy use reduction), and moisture transport due to improvements in airtightness. The calculator estimates the energy and cost savings potential based on the pre-and post-retrofit air leakage rates for prototype commercial buildings. The tool does not include the energy and hygrothermal impacts of air intrusion or air that flows into and out of the building enclosure from the same side. This article reports on the development of the Energy Savings and Moisture Transfer Calculator. This online tool aims to fill this void, is based on the best science available, and is easy to use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Simplified Methodology to Estimate Energy Savings in Commercial Buildings from Improvements in Airtightness

Air leakage through the envelope of commercial buildings in the United States accounts for approximately 6% of their energy use. Various simulation approaches have been proposed to estimate the impact of air leakage on building energy use. Although approaches that are based on detailed airflow modeling appear to be the most accurate to calculate infiltration heat transfer in simulation models, these approaches tend to require significant modeling expertise and effort. To make these energy savings estimates more readily available to building owners and designers, Oak Ridge National Laboratory, the National Institute of Standards and Technology, the Air Barrier Association of America, and the US Department of Energy (DOE) are developing a user-friendly online calculator that applies a detailed airflow modeling approach to examine energy savings due to airtightness in commercial buildings. The calculator, however, is limited to 52 US cities and a few cities in Canada and China. This paper describes the development of an alternative, simplified method to estimate energy savings from improved airtightness. The proposed method uses the same detailed approach for hourly infiltration calculations as the online calculator but it expands the ability to estimate energy savings to all US cities using hourly outdoor air temperature as the only input. The new simple regression model-based approach was developed and tested with DOE’s standalone retail prototype building model. Results from the new approach and the calculator show good agreement. In addition, a simple approach to estimate percent energy savings for retrofitted buildings was also developed; results were within 5% of the energy saving estimates from the online calculator.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination and Assessment of Optimum Internal Thermal Insulation for Masonry Walls in Historic Multifamily Buildings

A large portion of existing building stock is comprised of load-bearing masonry buildings, particularly in the Midwest and on the East Coast, though such buildings are distributed across the US. Most of them have uninsulated walls or suffer from insufficient thermal insulation materials. These buildings are inseparable parts of the cultural, social, and economic characteristics of their cities. Due to heritage and preservation concerns, zoning, and space restrictions, they cannot be retrofitted with exterior insulation. Interior insulation must therefore be considered as an alternative. Lack of insulation directly results in energy waste as well as heat loss and gain. Furthermore, it adversely affects heating, ventilation, and air conditioning (HVAC) loads, equipment sizing, indoor air quality, and thermal comfort for residents. The objective of this study is to simulate and evaluate the effects of various internal thermal insulation materials and strategies on mass masonry load-bearing walls in multifamily buildings with attention to various variables and parameters. It not only addresses the energy performance and cost savings associated with an interior insulation retrofit, but also outlines other variables and parameters that are factors in the selection of optimum insulation material, including installations costs, payback periods, useful internal space loss, and options for the depth of the interior insulation retrofit. In conclusion, the audience for this paper is diverse: homeowners, contractors and remodelers, architects and designers, engineers, housing and preservation authorities, and more can benefit from understanding the results outlined in this study.

42 ENGINEERING↗

Case Study: High Efficiency Dehumidification System (HEDS) Performance Modeling

JUMP connects innovators with industry partners to help bring new energy saving technologies to market. ORNL works with industry sponsors to develop calls for innovation that describe a technical challenge. The public and private sector businesses are then invited to submit their technology ideas to the JUMP program using an online interface by IdeaScale. Interested parties are encouraged to join the IdeaScale online community and to discuss technologies and to vote on them. A panel of technical experts then evaluates the idea submissions and, if a promising idea is identified, a JUMP winner is announced. In addition to the recognition given to the innovator by the JUMP program, typically the industry sponsor of the innovation call offers a monetary award. The industry sponsor and award winner then work together to refine the technology and further it towards the market. Since 2015 the JUMP program has included participation from a total of five national laboratories and fifteen industry sponsors in sixteen calls for innovation. The calls for innovation have engaged 1,446 online community members on 215 idea submissions. Seventy six percent of the businesses submitting ideas were small businesses.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Calibrated simulation analysis for integration of evaporative cooling and radiant cooling system for different Indian climatic zones

Radiant cooling system (RCS) has proven to be an energy efficient system for meeting a building's cooling requirements. RCS is energy efficient and provides better thermal comfort compared to conventional all-air heating ventilation air conditioning (HVAC) system. To further improve the efficiency of RCS, a parallel evaporative cooling system (cooling tower) is coupled with RCS and analyzed for different climatic condition using calibrated model. A statistical analysis of weather files (based on wet bulb temperature), was used to identify the availability of useful water for cooling tower integration with RCS. A comprehensive simulation feasibility study of the application of cooling tower in RCS was performed for different cities to cover every climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of different climatic zones, except warm-humid, is suitable for the integration of cooling tower with RCS. An experimental setup was designed and developed for integration of parallel chiller and cooling tower with panel-based RCS for cooling and a dedicated outdoor air system (DOAS) for dehumidification and ventilation. Experiments were conducted for chiller and cooling tower operated RCS in Composite climate of Jaipur, Rajasthan, India. Building Energy Models (BEM) were developed for both the chiller-operated RCS and cooling tower-operated RCS in EnergyPlus and calibrated with the measured data. Using the calibrated models, performance of the system was analyzed for different climatic zones of India. A chiller-operated RCS was considered as a baseline to compare the annual energy saving potential and monthly performance of the cooling tower integrated RCS. Here, in the cooling tower–operated RCS, a total annual savings of 7% in hot and dry climates, 11% in composite climates and 20% in temperate climates was achieved compared to the chiller-operated RCS.

54 ENVIRONMENTAL SCIENCES↗

New Air- and Water-Resistive Barriers -– Technology Verification

Infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning (HVAC) loads in commercial buildings. Air leakage is responsible for about 6% of the total energy used by the commercial building sector. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. These include the 3M 3015 primer-less self-adhered membrane, 3M 3015VP vapor permeable primer-less self-adhered membrane, and 3M 2085VP vapor permeable fluid-applied air barrier membrane. ORNL verified the performance of the 3M 3015, 3015VP and 2085VP air- and water- resistive barriers by conducting two field studies. The first one involved side-by-side evaluations in eight unoccupied test facilities in Cottage Grove, MN, that included the 3M membranes and commonly used air barrier materials such as a self-adhered membrane with primer and a mechanically-fastened membrane with taped joints. The facilities were monitored for 24 months and the collected data were used to calibrate simulation models that in turn were employed to calculate energy consumption and savings because of improvements in airtightness. After two years, results indicate that the test facilities with the new 3M technologies had leakage rates that were slightly lower than the buildings with traditional air barrier materials. The calibrated model for the test facility with the 3M 3015 membrane was used to calculate energy savings due to improved airtightness when compared to a building without an air barrier. Findings suggest that a building in Minneapolis, MN, or Fairbanks, AK, that has a properly installed air barrier system can have annual HVAC electricity use that is about 36% lower than if the building did not have an air barrier. Similarly, decreases in natural gas use can be about 25%. The second field evaluation involved the LifeSource building in Minneapolis, MN, and the Sierra Trading Post building in Woodbury, MN. Both of these were recently completed and use the 3M 3015 and 3015VP membranes as their air- and water- resistive barriers, respectively. Blower door test results show that LifeSource has an average air leakage rate of 0.06 cfm/ft 2 at 75 Pa, or 85% lower than the 0.4 cfm/ft 2 at 75 Pa specified in the 2015 International Energy Conservation Code (IECC). The leakage rate in the Sierra building is 0.15 cfm/ft 2 at 75 Pa or 63% than the IECC value. According to simulation results, LifeSource lowered its annual heating and cooling cost by about $\$$4600 or 10% when compared to a similar building that lacked an air barrier system. In the case of the Sierra building, savings were $5,900 or 41%. These field evaluations serve as examples of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrate the energy and financial savings that building envelopes with low air leakage rates could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of Microclimate Simulated weather data to ASHRAE Clear Sky Model and Measured Data

In anticipation of emerging global urbanization and its impact on microclimate, a need exists to better understand and quantify microclimate effects on building energy use. Satisfaction of this need will require coordinated research of microclimate impacts on and from “human systems.” The Urban Microclimate and Energy Tool (Urban-MET) project seeks to address this need by quantifying and analyzing the relationships among climatic conditions, urban morphology, land cover, and energy use; and using these relationships to inform energy-efficient urban development and planning. Initial research will focus on analysis of measured and modeled energy efficiency of various building types in selected urban areas and temporal variations in energy use for different urban morphologies under different microclimatic conditions. In this report, we analyze the differences between microclimate weather data sets for the Oak Ridge National Laboratory campus produced by ENVI-met and Weather Research Forecast (WRF) models, the ASHRAE clear sky which defines the maximum amounts of solar radiation that can be expected, and measured data from a weather station on campus. Errors with climate variables and their impact on building energy consumption will be shown for the microclimate simulations to help prioritize future improvement for use in microclimate simulation impacts to energy use of buildings.

54 ENVIRONMENTAL SCIENCES↗

LIQUIDARMOR CM Flashing and Sealant, High Impact Technology Demonstration

Air leakage is responsible for about 1.1 quads of energy or 6% of the total energy used by commercial buildings in the US. Consequently, infiltration and exfiltration are among the largest envelope-related contributors to the heating, ventilation, and air conditioning loads in commercial buildings. New air sealing technologies have recently emerged that aim to improve the performance of air barrier systems by simplifying their installation procedure. LIQUIDARMORTM CM Flashing and Sealant is an example of these new advanced material technologies. This technology is a spray-applied sealant and liquid flashing and can span gaps that are up to ¼ in. wide without a supporting material. ORNL verified the performance of LIQUIDARMORTM CM with field tests and energy simulations from a building in which LIQUIDARMORTM CM was one of components of the air barrier system. The Homeland Security Training Center (HTC) at the College of DuPage in Glen Ellyn, IL, served as the demonstration site. Blower door test results show the average air leakage rate in the demonstration site to be 0.15 cfm/ft2 at 1.57 psf, or 63% lower than the 0.4 cfm at 1.57 psf specified in the 2015 International Energy Conservation Code (IECC). According to simulation results, HTC lowered its annual heating and cooling cost by about $3,000 or 9% compared to a similar building that lacked an air barrier system. This demonstration project serves as an example of the level of building envelope airtightness that can be achieved by using air barrier materials that are properly installed, and illustrates the energy and financial savings that such an airtight envelope could attain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact Study of Metal Fasteners in Roofing Assemblies using Three-Dimensional Heat Transfer Analysis

Heat transfer analysis was performed on typical roofing assemblies using HEAT3, a three-dimensional heat transfer analysis software. The difference in heat transferred through the roofing assemblies considered is compared between two cases - without any steel fasteners and with steel fasteners. In the latter case, the metal roofing fasteners were arranged as per Factor Mutual Global (FMG) approvals, in the field, perimeter, and corner zones of the roof. The temperature conditions used for the analysis represented summer and winter conditions for three separate Climate Zones (CZ) namely Climate Zone 2 or CZ2 represented by Orlando, FL; CZ3 represented by Atlanta, GA; and CZ6 zone represented by St. Paul, MN. In all the climatic conditions, higher energy transfer was observed with increase in the number of metal fasteners attributed to high thermal conductivity of metals as compared to the insulation and other materials used in the roofing assembly. This difference in heat loss was also quantified in the form of percentage change in the overall or effective insulation of the roofing assembly for better understanding of the practical aspects. Besides, a comparison of 2D heat transfer analysis (using THERM software) and 3D analysis using HEAT3 is also discussed.

3D modeling↗

Multiyear Plan for Validation of EnergyPlus Multi-Zone HVAC System Modeling using ORNL's Flexible Research Platform

This document describes the Oak Ridge National Laboratory (ORNL) multiyear experimental plan for validation and uncertainty characterization of whole-building energy simulation for a multi-zone research facility using a traditional rooftop unit (RTU) as a baseline heating, ventilating, and air conditioning (HVAC) system. The project’s overarching objective is to increase the accuracy of energy simulation tools by enabling empirical validation of key inputs and algorithms. Doing so is required to inform the design of increasingly integrated building systems and to enable accountability for performance gaps between design and operation of a building. The project will produce documented data sets that can be used to validate key functionality in different energy simulation tools and to identify errors and inadequate assumptions in simulation engines so that developers can correct them. ASHRAE Standard 140, Method of Test for the Evaluation of Building Energy Analysis Computer Programs (ASHRAE 2004), currently consists primarily of tests to compare different simulation programs with one another. This project will generate sets of measured data to enable empirical validation, incorporate these test data sets in an extended version of Standard 140, and apply these tests to the Department of Energy’s (DOE) EnergyPlus software (EnergyPlus 2016) to initiate the correction of any significant deficiencies. The fitness-for-purpose of the key algorithms in EnergyPlus will be established and demonstrated, and vendors of other simulation programs will be able to demonstrate the validity of their products. The data set will be equally applicable to validation of other simulation engines as well.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Insulation materials for commercial buildings in North America: An assessment of lifetime energy and environmental impacts

In the United States, commercial buildings accounted for about 19 percent of the total primary energy consumption in 2012. Further, 29 percent of the site energy in commercial buildings was consumed for space heating and cooling. Applying insulation materials to building envelopes is an effective way of reducing energy consumption for heating and cooling, and limiting the negative environmental impacts from the buildings sector. While insulation materials have a net positive impact on the environment due to reduced energy consumption, they also have some negative impacts associated with their 'embodied energy'. The total lifetime environmental impacts of insulation materials are a summation of: (1) direct impacts due to their embodied energy, and (2) indirect or impacts avoided due to the reduced building energy consumption. Here, assessments of the lifetime environmental impacts of selected insulation materials are presented. Direct and indirect environmental impact factors were estimated for the cradle-to-grave insulation life cycle stages. Impact factors were calculated for two categories: primary energy consumption and global warming potential. The direct impact factors were calculated using data from existing literature and a life cycle assessment software. The indirect impact factors were calculated through simulations of a set of standard whole-building models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lifetime Energy and Environmental Impacts of Insulation Materials in Commercial Building Applications – Assessment Methodology and Sample Calculations

Application of insulation materials to building envelopes is a relatively easy and effective way of reducing energy consumption for space conditioning and, consequently, limiting the negative environmental impacts from the buildings sector. While insulation materials have a positive impact on the environment by reducing energy consumption in buildings, they also have some negative environmental impacts associated with their ‘embodied energy’. The total lifetime environmental impacts of insulation materials are a summation of: (1) direct impacts due to their embodied energy, and (2) indirect or environmental impacts avoided due to the reduced building energy consumption. It is important to identify insulation materials for buildings that will result in minimum negative environmental impacts. The objective of this project was to perform an assessment of the lifetime energy and environmental impacts of building insulation materials based on a previously developed protocol. The developed protocol was used for calculating the lifetime environmental impacts of selected insulation materials. Two Excel-based tools were developed: 1) to calculate embodied energy and GWP (equivalent CO 2 emissions) of insulation materials, and 2) to estimate energy savings and avoided environmental impacts due to the use of insulation materials in buildings. The direct environmental impacts were estimated using data from existing literature and life cycle analysis software; the indirect impacts were based on simulations of prototype whole-building models. This report summarizes the simulation study based on the recommendations of a previously developed protocol (A protocol for lifetime energy and environmental impact assessment of building insulation materials) by Shrestha et al., 2014. It also discusses a simplified algorithm based technique developed to quantify energy savings potential without requiring whole-building energy simulations. The report describes a proposed protocol that is intended to provide a comprehensive list of factors to be considered in evaluating the direct and indirect environmental impacts of building insulation materials, as well as detailed descriptions of standardized calculation methodologies to determine those impacts. Estimating the energy savings impact of insulation materials for the buildings in United States was an important aspect of this recommendation and comparative analyses of selected insulation materials were performed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗