Flexible Transformers for Resilient and Adaptable Power Systems

This paper presents experience with grid ready flexible transformer unit, which is in service for two years without any difficulty. Transformer unit is capable of changing short circuit impedance on load and it is equipped with state-of-the-art monitoring system.

field validation↗

FLEXIBLE POWER TRANSFORMERS TO IMPROVE RESILIENCY OF TRANSMISSION NETWORKS

For decades, transformer flexibility of operation has been limited to adjustable voltage ratio and, in some cases, several ratings with staged cooling. Transformers reconnectable to multiple voltage ratings have been primarily applied as emergency replacements. Other versions of “flexible transformers” were developed for continuous, long-term operation at specific sites, with application limited to large utilities. A new technology that supports today’s power systems adaptability requirements has been developed to provide not only voltage and power rating flexibility, but also an adjustable short-circuit impedance. This last, unique feature allows for a closer match to actual system operational requirements and could be used in the future to enhance resiliency and improve dynamic control of electrical grids. While the solution’s fundamentals have already been introduced in several technical forums, the intention of this article is to focus on the potential benefits of this new type of transformer and share the deployment experience of a full-scale prototype that has been in operation in a major U.S. utility since 2021

flexible transformer, resilient grid, variable lea↗

Flexible transformer system

A system includes conductive windings extending around a magnetic core and impedance-varying windings extending around the magnetic core. The impedance-varying windings include positive windings and negative windings. The conductive windings and the impedance-varying windings conduct electric current around the magnetic core. The system includes a first impedance tap changer that is electrically coupled with the positive windings of the impedance-varying windings and a second impedance tap changer electrically coupled with the negative windings of the impedance-varying windings. A controller controls the first impedance tap changer and the second impedance tap changer to change an impedance of the system by changing which portion of the positive windings and which portion of the negative windings are conductively coupled with the conductive windings, and which portion of the positive windings and which portion of the negative windings are disconnected from the conductive windings.

Ndiaye, Ibrahima↗