Engineering PapersSearch

Engineering topics

Berkery, E. A.

Publications and source records attributed to Berkery, E. A..

Yaw Attitude Estimation for the Tracking and Data Relay Satellite System

The Tracking and Data Relay Satellite System (TDRSS) uses a groundbased attitude determination algorithm to open loop point the satellite's high data rate antennas. The spacecraft is able to measure its pitch and roll attitude, but its yaw attitude is periodically unobservable. The ground software uses a state-space estimator, an adaptation of a Luenberger observer, to predict the spacecraft yaw angle during these unobservable periods. It contains states associated with the roll/yaw dynamics and the on-board control law. The accuracy is limited by the modeling fidelity of the disturbance torques acting on the spacecraft. After initial operating problems were cleared up, the operation of the estimator has converged to predicted performance.

Staich, S.

On-orbit control system performance of the HEAO-2 observatory

The on-orbit performance of the High Energy Astronomy Observatory is described. The control system utilizes precision gyros for attitude reference and skewed reaction wheels controlled by a reprogrammable computer. The observatory points at selected targets, maneuvers automatically and acquires guide stars for updating at each target. Performance data indicates maneuver accuracies less than one arc minute and pointing accuracies of 2-5 arc seconds. Use of 7th-9th magnitude guide stars has resulted in several improper updates caused by 'flat-field' stray light effects in the star trackers. The method used to discriminate true stars from the flat-field is also presented.

Rose, R. E.

On-orbit experience with the HEAO attitude control subsystem

The first satellite (HEAO-1) in the High Energy Astronomy Observatory Program series was launched successfully on Aug. 12, 1977. To date it has completed over nine months of orbital operation in a science data gathering mode. During this period all attitude control modes have been exercised and all primary mission objectives have been achieved. This paper highlights the characteristics of the attitude control subsystem design and compares the predicted performance with the actual flight operations experience. Environmental disturbance modeling, component hardware/software characteristics, and overall attitude control performance are reviewed and are found to compare very well with the prelaunch analytical predictions. Brief comments are also included regarding the operations aspects of the attitude control subsystem. The experience in this regard demonstrates the effectiveness of the design flexibility afforded by the presence of a general purpose digital processor in the subsystem flight hardware implementation.

Hoffman, D. P.

Research study on multi-KW DC distribution system

Power distribution system noise and transient stress on switchgear in large space vehicle power systems were investigated in terms of the effect of flight designs of long power distribution cables on load interface EMI requirements. A fifty meter cable pair was simulated to study interactions between the cable, load, and power source terminations. Power system noise characteristics were evaluated based on current spacecraft data, interface hardware filter designs, and power cable parameters. Parametric approaches were defined for evaluating switching transients at various distribution voltage levels. It is concluded that the state-of-the-art semiconductor switches represent a viable approach toward the implementation of power system design with distribution voltages of 120 VDC or less. The interface definition and design for the bus control unit was updated to be consistent with the established requirements.

Berkery, E. A.

Research study on multi-KW-DC distribution system

A detailed definition of the HVDC test facility and the equipment required to implement the test program are provided. The basic elements of the test facility are illustrated, and consist of: the power source, conventional and digital supervision and control equipment, power distribution harness and simulated loads. The regulated dc power supplies provide steady-state power up to 36 KW at 120 VDC. Power for simulated line faults will be obtained from two banks of 90 ampere-hour lead-acid batteries. The relative merits of conventional and multiplexed power control will be demonstrated by the Supervision and Monitor Unit (SMU) and the Automatically Controlled Electrical Systems (ACES) hardware. The distribution harness is supported by a metal duct which is bonded to all component structures and functions as the system ground plane. The load banks contain passive resistance and reactance loads, solid state power controllers and active pulse width modulated loads. The HVDC test facility is designed to simulate a power distribution system for large aerospace vehicles.

Berkery, E. A.

Multi-kw dc power distribution system study program

The first phase of the Multi-kw dc Power Distribution Technology Program is reported and involves the test and evaluation of a technology breadboard in a specifically designed test facility according to design concepts developed in a previous study on space vehicle electrical power processing, distribution, and control. The static and dynamic performance, fault isolation, reliability, electromagnetic interference characterisitics, and operability factors of high distribution systems were studied in order to gain a technology base for the use of high voltage dc systems in future aerospace vehicles. Detailed technical descriptions are presented and include data for the following: (1) dynamic interactions due to operation of solid state and electromechanical switchgear; (2) multiplexed and computer controlled supervision and checkout methods; (3) pulse width modulator design; and (4) cable design factors.

Berkery, E. A.