Engineering Papers⌕ Search

Engineering topics

Berhanu Bulcha

Publications and source records attributed to Berhanu Bulcha.

Superconducting Notch Filter for RFI Mitigation in Ground-Based Radio Telescope

This paper presents a high-rejection, thin-film HTS, microstrip bandstop filter to prevent a local and high-power RFI source from interfering with NASA GGAO’s VGOS cryogenic receiver. This filter has an excellent 2.7%, 50-dB-fractionalbandwidth and a center stop-band frequency of 9.41 GHz. It does not contain any narrow or interdigital features as found in some designs, which reduces the fringing electric fields and improves its power handling capability. The YBCO films were grown on 435-µm-thick R-plane sapphire substrate and the anisotropic behavior was modeled and simulated with a high degree of accuracy. The device was tested while cooled to 77 K and the measurements agree well with simulation.

high-temperature superconductors↗

SiAl Composite Feedhorn Arrays for Astrophysical Applications: Cryogenic Material Properties

A study investigating the physical properties and use of the SiAl composite Controlled Expansion 7 (CE7) for the packaging of silicon bolometric detectors for millimeter-wave astrophysical applications at cryogenic temperatures is presented. The existing interfaces to such detectors are typically made of either ductile metals or micro-machined silicon. As a composite of Si and Al, we find that CE7 exhibits properties of both in ways that may be advantageous for this application. This exploration of the physical properties of CE7 reveals: (a) superconductivity below a critical transition temperature, T_c ∼ 1.2 K; (b) a thermal contraction profile much closer to Si than metal substrates; (c) the relatively low thermal conductivity anticipated for a superconductor, which can be improved by Au-plating; and (d) the feasibility of machining mechanical features with tolerances of ∼25 µm. We further discuss the use of CE7 in the cosmology large angular scale surveyor telescope array, which deployed CE7 in several of its detector focal planes.

Aamir M. Ali↗

Optical Design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

This work describes the optical design of the EXperiment for Cryogenic Large-Aperture Intensity Mapping(EXCLAIM). EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbonmonoxide (CO) at redshiftsz <1 and ionized carbon ([CII]) at redshiftsz= 2.5−3.5 to probe star forma-tion over cosmic time in cross-correlation with galaxy redshift surveys. The EXCLAIM instrument will observeat frequencies of 420–540 GHz using six microfabricated silicon integrated spectrometers with spectral resolv-ing powerR= 512 coupled to kinetic inductance detectors (KIDs). A completely cryogenic telescope cooledto a temperature below 5 K provides low-background observations between narrow atmospheric lines in thestratosphere. Off-axis reflective optics use a 90-cm primary mirror to provide 4.2′full-width at half-maximum(FWHM) resolution at the center of the EXCLAIM band over a field of view of 22.5′. Illumination of the 1.7 Kcold stop combined with blackened baffling at multiple places in the optical system ensures low (<−40 dB) edgeillumination of the primary to minimize spill onto warmer elements at the top of the dewar.

Thomas Essinger-Hileman↗

Developing a New Generation of Integrated Micro-Spec Far Infrared Spectrometers for the EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The current state of far-infrared astronomy drives the need to develop compact, sensitive spectrometers for future space and ground-based instruments. Here we present details of the µ-Spec spectrometers currently in development for the far-infrared balloon mission EXCLAIM. The spectrometers are designed to cover the 555 – 714 µm range with a resolution of R = λ/∆λ = 512 at the 638 µm band center. The spectrometer design incorporates a Rowland grating spectrometer implemented in a parallel plate waveguide on a low-loss single-crystal Si chip, employing Nb microstrip planar transmission lines and thin-film Al kinetic inductance detectors (KIDs). The EXCLAIM µ-Spec design is an advancement upon a successful R = 64 µ-Spec prototype, and can be considered a sub-mm superconducting photonic integrated circuit (PIC) that combines spectral dispersion and detection. The design operates in a single M=2 grating order, allowing one spectrometer to cover the full EXCLAIM band without requiring a multi-order focal plane. The EXCLAIM instrument will fly six spectrometers, which are fabricated on a single 150 mm diameter Si wafer. Fabrication involves a flip-wafer-bonding process with patterning of the superconducting layers on both sides of the Si dielectric. The spectrometers are designed to operate at 100 mK, and will include 355 Al KID detectors targeting a goal of NEP ∼8 × 10−19 W/√( Hz). We summarize the design, fabrication, and ongoing development of these µ-Spec spectrometers for EXCLAIM.

Carolyn G. Volpert↗