Engineering Papers⌕ Search

Engineering topics

Benson, Stephen

Publications and source records attributed to Benson, Stephen.

41 records · Page 3

Advanced Laser Personnel Safety System at Jefferson Lab

Jefferson Lab operates a versatile user facility for a broadband tunable free-electron laser. The facility has the capability of using both the high power FEL as well as both low (class 3b) and high power (class 4) conventional lasers. We have developed a user-friendly laser protection system that allows operation with many different lasers at many different wavelengths in a safe but convenient manner. This presentation describes the laser facility, some of the unique laser hazards in it, and how the hazards are ameliorated. Some new systems for operating in environments with the potential for multiple laser wavelengths will also be introduced. * This work was supported by U.S. DOE Contract No. DE-AC05-84-ER40150, the Office of Naval Research, and the Joint Technology Office.

Benson, Stephen↗

JLab FEL DC Gun

The Jefferson Lab (JLab) Energy Recovery Linac 10 kW IR Upgrade Free Electron Laser (FEL) is driven by a 350kV DC un-polarized photoemission electron gun. In 2003, an upgrade version of the earlier 1 kW IR Demo FEL gun delivered over 1000 Coulombs with a single Cs:GaAs wafer in one year of operation. Between 2004 and 2007 a second wafer delivered over 7000 Coulombs and up to 9 mA CW beam for FEL operations. Both wafers suffered surface damage with total loss of quantum efficiency in several occasions during high current operations. Since then, the electron gun has been refurbished two times due to field emission damage. Although presently operating at nominal 350kV, field emission has significantly decreased the photocathode lifetime.

Hernandez-Garcia, Carlos↗

Study of Optical Frequency Chirping and Pulse Compression in a High-Gain Energy-Recovery-Linac-Based Free-Electron Laser

In this paper we report a direct experimental investigation of optical frequency chirping effects induced by ultrashort electron bunches in a high-gain energy-recovery-linac (ERL) free-electron laser (FEL) cavity. Our measurement and analysis shows clear evolution of the optical pulse chirp verses the electron bunch energy chirp. Further study also provides important evidence that under certain conditions much shorter FEL pulses can be obtained through properly chirping electron bunches and optical pulse compression. Although studies about the chirp measurement on Self-amplified-spontaneous-emission (SASE) FEL were reported recently, we believe this paper for the first time provides a comprehensive and close observation into the very unique temporal and spectral characteristics of ultrashort optical pulses from a high-gain ERL FEL. This is made possible by the stable operation and unique capability of the Jefferson Lab machine to change the electron bunch energy chirp with no curvature. Preliminary simulations will also be presented.

Zhang, Shukui↗

Short Rayleigh length free electron laser: Experiments and simulations

DOI: http://dx.doi.org/10.1103/PhysRevSTAB.11.090701<br /> We report experiments at Jefferson National Accelerator Facility (Jlab) and computer simulations performed at the Naval Postgraduate School (NPS) designed to probe the small Rayleigh length regime. We compare the gain, power, and sensitivity to mirror and electron beam misalignments as a function of decreasing Rayleigh length. The agreement is quite good, with experiments and simulations showing comparable trends as the Rayleigh length is decreased. In particular, we find that the gain and power do not decrease substantially at short Rayleigh length, contrary to a common Gaussian-mode filling factor argument. Within currently achievable alignment tolerances, the gain and power are still acceptable for FEL operation.

43 PARTICLE ACCELERATORS↗

Multi-component measurements of the Jefferson Lab energy recovery linac electron beam using optical transition and diffraction radiation

DOI: http://dx.doi.org/10.1103/PhysRevSTAB.11.082801 High brightness electron accelerators, such as energy recovery linacs (ERL), often have complex particle distributions that can create difficulties in beam transport as well as matching to devices such as wigglers used to generate radiation from the beam. Optical transition radiation (OTR), OTR interferometry (OTRI) and optical diffraction-transition radiation interferometry (ODTRI) have proven to be effective tools for diagnosing both the spatial and angular distributions of charged particle beams. OTRI and ODTRI have been used to measure rms divergences and optical transverse phase space mapping has been demonstrated using OTRI. In this work we present the results of diagnostic experiments using OTR and ODR conducted at the Jefferson Laboratory 115 MeV ERL which show the presence of two separate components within the spatial and angular distributions of the beam. By assuming a correlation between the spatial and angular fe

43 PARTICLE ACCELERATORS↗