Engineering Papers⌕ Search

Engineering topics

Benoit, Evan

Publications and source records attributed to Benoit, Evan.

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Evaluation of Impedance Measurement Using Spread Spectrum Time Domain Reflectometry

We evaluate the feasibility of spectral time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) as a new modality for impedance measurement to test energized/noisy systems over a very broad frequency spectrum (near dc to gigahertz) as well as multiple channels in parallel. We simulate how the S/SSTDR signal parameters (signal-to-noise ratio (SNR) frequency and length of the pseudo-noise (PN) signals) affect the accuracy and usable frequency band for reflection coefficient and impedance measurement. An initial measurement validation is included. Here, we conclude with a recommendation of what will be required for a viable multichannel impedance (and reflection, transmission coefficient) measurement system for either energized or nonenergized systems, in noisy environments, that can test multiple channels simultaneously.

14 SOLAR ENERGY↗

A SSTDR Methodology, Implementations, and Challenges

Sequence time-domain reflectometry (STDR) and spread spectrum time-domain reflectometry (SSTDR) detect, locate, and diagnose faults in live (energized) electrical systems. In this paper, we survey the present SSTDR literature for discussions on theory, algorithms used in its analysis, and its more prominent implementations and applications. Our review includes both scientific litera-ture and selected patents. We also discuss future applications of SSTDR.

14 SOLAR ENERGY↗

Spread Spectrum Time Domain Reflectometry (SSTDR) Digital Twin Simulation of Photovoltaic Systems for Fault Detection and Location

Utilizing spread spectrum time domain reflectometry (SSTDR) to detect, locate, and characterize faults in photovoltaic (PV) systems is examined in this paper. We present a method to obtain the model parameters that are needed to produce digital twin SSTDR responses for PV systems. The digital twin SSTDR responses could be used to predict faults within the PV systems. Here, the model parameters are the reflection and transmission coefficients at each impedance discontinuity in the PV system along with the propagation coefficients across each PV cable segment. We obtain model parameter by applying inverse modeling techniques to experimental SSTDR data associated with PV systems. Our model parameters can be used in any digital twin simulation method for modeling reflectometry in frequency-dependent and complex loads. For validation, we used the model parameters in a graph network simulation engine and adapted it to be used for SSTDR digital twin simulations in PV systems. We produced simulations for 0 to 10 PV modules connected in series. We also simulated SSTDR responses for open circuit disconnections in a PV setup containing 10 PV modules in series. Results show that all but one simulated disconnect locations match experimental disconnection locations of the same setup with an error of less than 5%.

14 SOLAR ENERGY↗

Spread Spectrum Time Domain Reflectometry and Steepest Descent Inversion to Measure Complex Impedance

In this paper, we present a method for estimating complex impedances using reflectometry and a modified steepest descent inversion algorithm. We simulate spread spectrum time domain reflectometry (SSTDR), which can measure complex impedances on energized systems for an experimental setup with resistive and capacitive loads. A parametric function, which includes both a misfit function and stabilizer function, is created. The misfit function is a least squares estimate of how close the model data matches observed data. The stabilizer function prevents the steepest descent algorithm from becoming unstable and diverging. Steepest descent iteratively identifies the model parameters that minimize the parametric function. We validate the algorithm by correctly identifying the model parameters (capacitance and resistance) associated with simulated SSTDR data, with added 3 dB white Gaussian noise. With the stabilizer function, the steepest descent algorithm estimates of the model parameters are bounded within a specified range. Furthermore, the errors for capacitance (220pF to 820pF) and resistance (50 Ω to 270 Ω) are < 10%, corresponding to a complex impedance magnitude |R +1/jωC| of 53 Ω to 510 Ω.

14 SOLAR ENERGY↗

An Overview of Spread Spectrum Time Domain Reflectometry Responses to Photovoltaic Faults

Spread spectrum time domain reflectometry (SSTDR) is a broadband electrical reflectometry technique that has been used to detect and locate faults on live electrical systems, including photovoltaic systems. In this article, we evaluate the detectability and localizability from both existing literature and our own measurements using SSTDR of open-circuit faults, connection faults, short-circuit faults, ground faults, arc faults, shading faults, bypass diode faults, and accelerated degradation faults in PV cells and mini-modules. Additionally, reflection magnitudes for these faults are compared. Herein, preliminary data on buried and grounded PV cable along with arc fault detection are presented.

14 SOLAR ENERGY↗

Detection and Localization of Disconnections in PV Strings Using Spread-Spectrum Time-Domain Reflectometry

This article describes the novel use of spread-spectrum time-domain reflectometry (SSTDR) for detecting and locating disconnection faults in photovoltaic (PV) power plants. We measure strings of cells and full-sized modules to understand how disconnections affect the reflectometry signature. PV modules correspond to reactive loads and disconnections in a PV string and cause distinguishable and measurable changes in SSTDR responses. Disconnection faults are manually introduced and correctly identified and localized applying the proposed technique. The SSTDR technique can detect and locate disconnects through at least eight 36-cell modules. Using the new technique described in this article, we can both detect and locate the disconnections within a 1-ft resolution, on average.

14 SOLAR ENERGY↗

Postprocessing for Improved Accuracy and Resolution of Spread Spectrum Time-Domain Reflectometry

Reflectometry, which is commonly used for locating faults on electrical wires, produces sampled time domain signatures with peaks that are often missed due to this sampling. Resultant errors in these sampled peaks translate to errors in calculating the impedance and location of the fault. Typical signal processing methods to improve the accuracy of these sampled peaks have complexity on the order of O(N 2 ). For embedded fault location applications, algorithms with lower complexity are desired. In this article, we introduce three algorithms for improving the accuracy of the peak with a complexity of O(N). Finally, we evaluate these algorithms on the practical case of calculating the velocity of propagation and the characteristic impedance of a photovoltaic (PV) cable using spread spectrum time-domain reflectometry.

47 OTHER INSTRUMENTATION↗

Spread Spectrum Time Domain Reflectometry for Complex Impedances: Application to PV Arrays

Spread spectrum time domain reflectometry (SSTDR) has previously been used for detection and location of intermittent faults on live electrical wiring. These intermittent faults can be open circuits, short circuits, or resistive changes, all of which preserve the original shape of the SSTDR correlated waveform. But things are very different when SSTDR encounters a complex impedance discontinuity such as a capacitor or inductor. In this case, the reflection is a function of frequency, changing the shape of the SSTDR signature. In this paper, we will show the SSTDR response to single capacitors and inductors. We will also explore how SSTDR responds to arrays of PV panels (which are capacitive) connected by wires. We will show both simulations and measurements. In some configurations, it is relatively easy to see faults, although algorithms are still under development. In other configurations, little change occurs, which makes it very difficult to create a system for testing for these faults.

14 SOLAR ENERGY↗