Engineering Papers⌕ Search

Engineering topics

Benedetti, L R

Publications and source records attributed to Benedetti, L R.

At least 19 records

Timing characterization of fast hCMOS sensors

We describe a method of analyzing gate profile data for ultrafast x-ray imagers that allows pixel-by-pixel determination of temporal sensitivity in the presence of substantial background oscillations. With this method, systematic timing errors in gate width and gate arrival time of up to 1 ns (in a 2 ns wide gate) can be removed. In-sensor variations in gate arrival and gate width are observed, with variations in each up to 0.5 ns. This method can be used to estimate the coarse timing of the sensor, even if errors up to several ns are present.

Benedetti, L. R. (ORCID:0000000160502983)↗

Achieving 280 Gbar hot spot pressure in DT-layered CH capsule implosions at the National Ignition Facility

We are reporting on a series of indirect-drive 0.9-scale CH capsule implosions (inner radius = 840 μm) fielded in low gas-fill (0.6 mg/cm 3 ) hohlraums of 6.72 mm diameter at the National Ignition Facility. Thanks to the 11%-reduction of the capsule size at a given hohlraum diameter compared to previously tested full-scale capsules, we achieved good hot spot symmetry control near 33% cone-fraction and without the need to invoke cross beam energy transfer. As a result, we achieved a hot spot pressure of 280 ± 40 Gbar, which is the highest pressure demonstrated in layered DT implosions with CH capsules to date. Pushing this design to higher velocity resulted in a reduction of neutron yield. Highly resolved capsule simulations suggest that higher Au M-shell preheat resulted in an increase in Atwood number at the ablator–ice interface, which leads to increased fuel-ablator instability and mixing. The results reported here provide important scaling information for next-generation CH designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the relationship between noise transfer inside the x-ray framing cameras and their imaging ability

We apply a cascaded linear model analysis to a micro-channel plate x-ray framing camera. We establish a theoretical expression of the Noise Power Spectrum (NPS) at the detector’s output and assess its accuracy by comparing it to the NPS of Monte Carlo simulations of the detector’s response to a uniform illumination. We also reflect that fitting the NPS of experimental data against a parametric model based on this expression can yield valuable information on the imaging ability of framing cameras, offering an alternative method to the usual avenue employed to measure their modulation transfer functions.

25 ENERGY STORAGE↗

Hydrodynamic instabilities and mix studies on NIF: predictions, observations, and a path forward

The goals of the Mix Campaign are to determine how mix affects performance, locate the "mix cliff", locate the source of the mix, and develop mitigation methods that allow performance to be increased. We have used several different drive pulse shapes and capsule designs in the Mix Campaign, to understand sensitivity to drive peak power, level of coast, rise time to peak power, adiabat, and dopant level in the capsule. Ablator material mixing into the hot spot has been shown conclusively with x-ray spectroscopy. The observed neutron yield drops steeply when the hot spot mix mass becomes too large. The mix appears to be driven by ablation- front Rayleigh-Taylor instabilities. A high foot, higher adiabat drive has a more stable ablation front and has allowed the mix mass in the hot spot to be reduced significantly. We found two recent high foot shots achieved neutron yields > 10 15 and measured neutron yield over clean 1D simulation (YOC) > 50%, which was one of the central goals of the Mix Campaign.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnosing residual motion via the x-ray self emission from indirectly driven inertial confinement implosions

In an indirectly driven implosion, non-radial translational motion of the compressed fusion capsule is a signature of residual kinetic energy not coupled into the compressional heating of the target. A reduction in compression reduces the peak pressure and nuclear performance of the implosion. Measuring and reducing the residual motion of the implosion is therefore necessary to improve performance and isolate other effects that degrade performance. Using the gated x-ray diagnostic, the x-ray Bremsstrahlung emission from the compressed capsule is spatially and temporally resolved at x-ray energies of >8.7 keV, allowing for measurements of the residual velocity. Here details of the x-ray velocity measurement and fitting routine will be discussed and measurements will be compared to the velocities inferred from the neutron time of flight detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental investigation of bright spots in broadband, gated x-ray images of ignition-scale implosions on the National Ignition Facility

Bright spots in the hot spot intensity profile of gated x-ray images of ignition-scale implosions at the National Ignition Facility [G. H. Miller et al., Opt. Eng. 443, (2004)] are observed. X-ray images of cryogenically layered deuterium-tritium (DT) and tritium-hydrogen-deuterium (THD) ice capsules, and gas filled plastic shell capsules (Symcap) were recorded along the hohlraum symmetry axis. Heterogeneous mixing of ablator material and fuel into the hot spot (i.e., hot-spot mix) by hydrodynamic instabilities causes the bright spots. Hot-spot mix increases the radiative cooling of the hot spot. Fourier analysis of the x-ray images is used to quantify the evolution of bright spots in both x- and k-space. Bright spot images were azimuthally binned to characterize bright spot location relative to known isolated defects on the capsule surface. A strong correlation is observed between bright spot location and the fill tube for both Symcap and cryogenically layered DT and THD ice targets, indicating the fill tube is a significant seed for the ablation front instability causing hot-spot mix. The fill tube is the predominant seed for Symcaps, while other capsule non-uniformities are dominant seeds for the cryogenically layered DT and THD ice targets. A comparison of the bright spot power observed for Si- and Ge-doped ablator targets shows heterogeneous mix in Symcap targets is mostly material from the doped ablator layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗