Engineering PapersSearch

Engineering topics

Beiersdorfer, P.

Publications and source records attributed to Beiersdorfer, P..

At least 19 records

Rest-wavelength Fiducials for the ITER Core Imaging X-ray Spectrometer

Absolute wavelength references are needed to derive the plasma velocities from the Doppler shift of a given line emitted by a moving plasma. We show that such reference standards exist for the strongest x-ray line in neonlike W64+, which has become the line of choice for the ITER (Latin the way) core imaging x-ray spectrometer. Close-by standards are the Hf L3 line and the Ir L2 line, which bracket the W64+ line by 30 eV; other standards are given by the Ir L1 and L2 lines and the Hf L1 and L2 lines, which bracket the W64+ line by 40 and 160 eV, respectively. The reference standards can be produced by an x-ray tube built into the ITER spectrometer. We present spectra of the reference lines obtained with an x-ray microcalorimeter and compare them to spectra of the W64+ line obtained both with an x-ray microcalorimeter and a crystal spectrometer

Rest-wavelength

Laboratory Measurements of the Dielectronic Recombination Satellite Transitions of He-Like FE XXV and H-Like FE XXVI

We present laboratory spectra of dielectronic recombination (DR) satellite transitions attached to the He-like and H-like iron resonance lines obtained with the NASA Goddard Space Flight Center X-ray calorimeter and produced by a thermal plasma simu1ation technique on the EBIT-I electron beam ion trap at the Lawrence Livermore National Laboratory. We demonstrate that the calorimeter has sufficient spectral resolution in the 6-9 keV range to provide reliable measurements not only of standard DR satellite to resonance line intensities but also of DR satellite to DR satellite ratios that can be used to diagnose nonthermal electron distributions. Electron temperatures derived from the measured line intensities are consistent with the temperature of the simulated plasma. Temperature measurements based on DR satellite transitions have significant advantages over those based on collisional ionization equilibrium or continuum shape. Thus, successful demonstration of this method with the X-ray calorimeter is an important step fur its application in X-ray astronomy.

Gu, M. F.

Measurement of Anomalously Strong Emission from the 1s-9p Transition in the Spectrum of H-like Phosphorus Following Charge Exchange with Molecular Hydrogen

We have measured K-shell x-ray spectra of highly ionized argon and phosphorus following charge exchange with molecular hydrogen at low collision energy in an electron beam ion trap using an x-ray calorimeter array with approx.6 eV resolution. We find that the emission at the high-end of the Lyman series is greater by a factor of two for phosphorus than for argon, even though the measurement was performed concurrently and the atomic numbers are similar. This does not agree with current theoretical models and deviates from the trend observed in previous measurements.

Leutenegger, M. A.

High Performance Non-Dispersive X-Ray Spectrometers for Charge Exchange Measurements

Currently, the only measurements of cosmological charge exchange have been made using low resolution, non-dispersive spectrometers like the PSPC on ROSAT and the CCD instruments on Chandra and XMM/Newton. However, upcoming cryogenic spectrometers on Astro-H and IXO will add vast new capabilities to investigate charge exchange in local objects such as comets and planetary atmospheres. They may also allow us to observe charge exchange in extra-solar objects such as galactic supernova remnants. With low spectral resolution instruments such as CCDs, x-ray emission due to charge exchange recombination really only provides information on the acceptor species, such as the solar wind. With the new breed of x-ray calorimeter instruments, emission from charge exchange becomes highly diagnostic allowing one to uniquely determine the acceptor species, ionization state, donor species and ionization state, and the relative velocity of the interaction. We will describe x-ray calorimeter instrumentation and its potential for charge exchange measurements in the near term. We will also touch on the instrumentation behind a decade of high resolution measurements of charge exchange using an x-ray calorimeter at the Lawrence Livermore National Laboratory.

Porter Frederick

Laboratory Measurements of the X-ray Line Emission from Neon-like Fe XVII

We have conducted a systematic study of the dominant x-ray line emission from Fe XVII. These studies include relative line intensities in the optically thin limit, intensities in the presence of radiation from satellite lines from lower charge states of iron, and the absolute excitation cross sections of some of the strongest lines. These measurements were conducted at the Lawrence Livermore National Laboratory electron beam ion trap facility using crystal spectrometers and a NASA-Goddard Space Flight Center microcalorimeter array.

Brown, G. V.

Electron Impact Excitation Cross Section Measurement for n=3 to n=2 Line Emission in Fe(17+) to Fe(23+)

We have measured the electron impact excitation cross sections for the strong iron L-shell 3 --> 2 lines of Fe XVIII to Fe XXIV at the EBIT-I electron beam ion trap using a crystal spectrometer and NASA-Goddard Space Flight Centers 6 x 6 pixel array microcalorimeter. The cross sections were determined by direct normalization to the well established cross section of radiative electron capture through a sophisticated model analysis which results in the excitation cross section for the strong Fe L-shell lines at multiple electron energies. This measurement is part of a laboratory X-ray astrophysics program utilizing the Livermore electron beam ion traps EBIT-I and EBIT-II.

Chen, H.

Magnetic-Field Sensitive Line Ratios in EUV and Soft X-ray Spectra

We discovered a class of lines that are sensitive to the strength of the ambient magnetic field, and present a measurement of such a line in Ar IX near 49 A. Calculations show that the magnitude of field strengths that can be measured ranges from a few hundred gauss to several tens of kilogauss depending on the particular ion emitting the line.

Beiersdorfer, P.

Laboratory Measurements of the Line Emission from Mid-Z L-Shell Ions in the EUV

We are continuing EBIT measurements of line lists in the EUV region for use as astrophysical diagnostics and have recently measured the same transitions in much denser plasma of the NSTX tokamak. This allows us to calibrate density-sensitive line ratios at their upper limits. We compare our observations at low and high density with calculations from the Flexible Atomic Code.

Lepson, J. K.

Measurements of K Shell Emission of Highly Charged Ions with the XRS at EBIT

The XRS/EBIT is a 32 channel microcalorimeter spectrometer operating at the electron beam ion trap (EBIT) facility at Lawrence Livermore National Laboratory. The system contains a flight candidate detector array from the XRS instrument for the Astro-E2 mission. The detector array in the XRS/EBIT is functionally identical to the flight array integrated into the XRS instrument and benefits from the enormous amount of calibration data from the XRS program. Since the XRSEBIT was upgraded with the new detector array in October 2003, the system has been used for a number of experiments including a survey of the K shell emission from He-like and H-like O, Ne, Ar, Fe, Ni and Kr as well as for L shell emission to measure the 3C/3D line ratio in Ni. Here we present some basic operational parameters of the instrument as well as direct excitation and simulated maxwellian spectra of He-like and E-like Fe. We show that the XRS instrument can resolve the Lyal and Lya2 lines from each other as well as from the dielectronic recombination satellites in thermal H-like Fe. We also show exactly how well the XRS instrument on Astro-E2 will resolve the thermal He-like triplet in collisionally excited Fe. This work was funded under NASA's Research Opportunities in Space Science program.

Porter, F. Scott

Emission Line Spectra in the Soft X-ray Region 20 - 75 Angstroms

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EDIT-II, emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region were studied. Observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 Angstrom are presented to illustrate our work.

Lepson, J. K.

Laboratory Studies of the X-ray Emission Produced by the Interaction of Solar Wind Heavy Ions with Comets

The process of X-ray emission following charge exchange between solar wind heavy ions and cometary gases is studied in the laboratory. The emission is recorded with the spare ASTRO-E 6x6 microcalorimeter array. The microcalorimeter affords a resolution of better than 10 eV in the range of X-ray energies of interest arid thus individual emission lines can be resolved. Our present measurements focus on the most abundant K-shell heavy ions found in the solar wind. In particular, we measure the K-shell emission of bare C, N, O, and Ne, and their hydrogenlike counter parts interacting with such gases as CO2, N2, and CH4. Several results are noted that had not been considered in the early cometary X-ray models.

Beiersdorfer, P.

Laboratory Study of the Diagnostic Utility of the 3C/3D Line Ratio in Fe XVII

Fe XVII X-ray emission is present in a multitude of sources, such as the corona of the Sun, Capella, and Procyon. Two of the strongest lines observed in these spectra are the resonance and intercombination lines located at 15.01 and 15.26 A, respectively. As part of the laboratory astrophysics program at the electron beam ion traps EBIT-I & EBIT-II located at the Lawrence Livermore National Laboratory we have measured this line ratio for the case where the relative abundance of Fe XVI to Fe XVII is approx. 1. Our results show that an Fe XVI innershell satellite line coincides with the intercombination line and can significantly reduce the relative intensity, R, of the resonance to intercombination line. The fact that the apparent relative intensity of the resonance and intercombination line in Fe XVII is sensitive to the strength of an Fe XVI innershell satellite, and therefore, tho relative abundance of Fe XVI to Fe XVII, makes the line ratio a diagnostic of temperature, and explains the anomalously low ratios observed in the solar and stellar coronae.

Brown, G. V.

Laboratory Astrophysics at the LLNL Electron Beam Ion Traps: EBIT-I and EBIT-II

In order to provide a complete, accurate set of atomic data for interpreting spectra provided by missions such as XMM-Newton, the Chandra X-Ray Observatory, and Astro-E2, we have harnessed the Lawrence Livermore National Laboratory's electron beam ion traps EBIT-I. EBIT-II, and Super-EBIT for laboratory astrophysics. In support of this work we have developed a number of unique techniques, including the ability to experimentally simulate a Maxwellian distribution of electron energies and measuring low-energy charge exchange cross sections using the magnetic trapping mode. We have also built and operated a full suite of spectrometers spanning the 1-7000 Angstrom wavelength band, the most recent being a spectrometer based on a spare Astro-E (6 x 6) microcalorimeter array. Results of our efforts include a complete list of wavelengths of the Fe L-shell transitions, measurements of absolute and relative cross sections for direct impact, dielectronic, and resonance excitation, and measurements of low energy charge transfer reactions. A brief overview of the LLNL ebit facility, its capabilities, and some results will be discussed.

Brown, G. V.

New Insights into the X-Ray Spectra of Heliumlike and Neonlike Ions

Recent measurements of the K-shell and L-shell x-ray spectra of highly charged helium- like and neonlike ions are presented that were performed on the Livermore electron beam ion traps and the Princeton tokamaks. These measurements provide new insights into collisional and indirect line formation processes, identifications of forbidden lines, and a new plasma line diagnostic of magnetic field strength.

IONS

Laboratory Data for X-Ray Astronomy

Laboratory facilities have made great strides in producing large sets of reliable data for X-ray astronomy, which include ionization and recombination cross sections needed for charge balance calculations as well as the atomic data needed for interpreting X-ray line formation. We discuss data from the new generation sources and pay special attention to the LLNL electron beam ion trap experiment, which is unique in its ability to provide direct laboratory access to spectral data under precisely controlled conditions that simulate those found in many astrophysical plasmas. Examples of spectral data obtained in the 1-160 A wavelength range are given illustrating the type of laboratory X-ray data produced in support of such missions as Chandra, X-Ray Multi-Mirror telescope (XMM), Advanced Satellite for Cosmology and Astrophysics (ASCA) and Extreme Ultraviolet Explorer Satellite (EUVE).

Beiersdorfer, P.

Emission Line Spectra from Low-Density Laboratory Plasmas

Using spectroscopic equipment optimized for laboratory astrophysics, we are performing systematic measurements of the line emission from astrophysically relevant ions in the wavelength band between 1 and 400 Angstroms important to X-ray missions such as Chandra, XMM, Astro-E, and EUVE. Obtained in a controlled laboratory setting at electron densities similar to those found in stellar coronae, the data are used to test spectral modeling codes for accuracy and completeness. Our effort includes the compilation of the iron L-shell emission lines from 6-18 Angstroms and the iron M-shell emission lines from 50-200 Angstroms. Many lines have been identified for the first time, and the fluxes from lines missing in the spectral modeling codes are assessed. Our measurements also assess the accuracy of line excitation calculations, including direct electron-impact excitation, dielectronic recombination, and resonance excitation. These measurements yield a calibration of specific diagnostic line ratios. Examples of our current measurements are given.

Beiersdorfer, P.