Engineering PapersSearch

Engineering topics

Becker, Joseph F.

Publications and source records attributed to Becker, Joseph F..

Stable Isotope Laser Spectrometer for Exploration of Mars

On Earth, measurements of the ratios of stable carbon isotopes have providet much information about geological and biological processes. For example, fractionation of carbon occur in biotic processes and the retention of a distinctive 2-4% contrast in C-13/C-12 between organic carbon and carbonates in rocks as old as 3.8 billion years constitutes some of the firmest evidence for the antiquity of life on the Earth. We have developed a prototype tunable diode laser spectrometer which demonstrates the feasibility of making accurate in situ isotopic ratio measurements on Mars. This miniaturized instrument, with an optical path length of 10 cm should be capable of making accurate C-13/C-12 and N-15/N-14 measurements. Gas samples for measurement are to be produced by pyrolysis using soil samples as small as 50 mg. Measurements of C-13/C-12, O-18/O-16 and N-15/N-14 have been made to a precision of better than 0.1%, and various other isotopes are feasible. This laser technique, which relies on the extremely narrow emission linewidth of tunable diode lasers (less than 0.001/ cm),has favorable features in comparison to mass spectrometry, the standard method of accurate isotopic ratio measurement. The miniature instrument could be ready to deploy c 2003 or other Mars lander missions.

Sauke, Todd B.

Interchange for Joint Research Entitled: Measurement of Stable Nitrogen and Sulfur Isotopes

Viking measurements of the Martian atmosphere indicate a value of N-15/N-14 which is markedly greater than that found in Earth's atmosphere. These isotopic measurements provide a powerful diagnostic tool which may be used to derive valuable information regarding the past history of Mars and they have been used to place important constraints on the evolution of Mars' atmosphere. Initial partial pressures of nitrogen, outgassing rates, and integrated deposition of nitrogen into minerals have been calculated from this important atmospheric data (McElroy et al., 1976 and 1977; Fox and Dalgarno, 1983). The greater precision obtained in laser spectrometer isotopic measurements compared to the Viking data will greatly improve these calculated values. It has also been proposed that the N-15/N-14 value in Mars' atmosphere has increased monotonically over time (McElroy et al., 1977; Fox and Dalgarno, 1983; Wallis, 1989) owing to preferential escape of atmospheric 14N to space. Nitrogen isotopic ratios might be used to identify relatively ancient crustal rocks (R. Mancinelli, personal communication), and perhaps determine relative aces of surface samples. As a first step in successfully measuring nitrogen isotopes optically we have demonstrated the measurement of 15NI14N to a precision of 0.1% (See Figures 1-4) using a tunable diode laser and an available gas (N-,O) with spectral lines in the 2188 cm-1 region. The sample and reference gas cells contained gases of identical isotopic composition so that the 15NI14N absorption ratio determined from the sample cell, when divided by the 15NI14N absorption ratio determined from the reference cell, should yield an ideal value of unity. The average measured value of this "ratio of ratios" was 0.9983 with a standard deviation (20 values) of 0.0010. This corresponds to a precision of 0.1% (1 per mil) for nitrogen isotopes, a value sufficiently precise to provide important isotopic data of interest to exobiologists. The precision presently attainable in gases is sufficient to permit the instrument to be used in the measurement of isotopic ratios of interest to exobiologists as well as geologists and planetary scientists.

Becker, Joseph F.

Monitoring of Time-Dependent System Profiles by Multiplex Gas Chromatography with Maximum Entropy Demodulation

The maximum entropy technique was successfully applied to the deconvolution of overlapped chromatographic peaks. An algorithm was written in which the chromatogram was represented as a vector of sample concentrations multiplied by a peak shape matrix. Simulation results demonstrated that there is a trade off between the detector noise and peak resolution in the sense that an increase of the noise level reduced the peak separation that could be recovered by the maximum entropy method. Real data originated from a sample storage column was also deconvoluted using maximum entropy. Deconvolution is useful in this type of system because the conservation of time dependent profiles depends on the band spreading processes in the chromatographic column, which might smooth out the finer details in the concentration profile. The method was also applied to the deconvolution of previously interpretted Pioneer Venus chromatograms. It was found in this case that the correct choice of peak shape function was critical to the sensitivity of maximum entropy in the reconstruction of these chromatograms.

Becker, Joseph F.

Stable isotope analysis using tunable diode laser spectroscopy

Ratios of C-12/C-13 in CO2 have been measured using a tunable diode laser (TDL) spectrometer to an accuracy of better than 0.4 percent. These results were made possible by the use of state-of-the-art high-temperature TDLs, an etalon and wavenumber calibration technique, high-speed assembly language controlled data acquisition, and the ratioing of absorbances from simultaneously acquired sample and reference data scans. The dual beam spectrometer that is employed uses the sweep integration technique in a spectral region where adjacent spectral lines are of approximately equal absorbance at the expected isotopic abundances.

Becker, Joseph F.

Continuous monitoring of a changing sample by multiplex gas chromatography

Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.

Valentin, Jose R.