Engineering Papers⌕ Search

Engineering topics

Becker, Eric M.

Publications and source records attributed to Becker, Eric M..

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Radiological Data Assessment Guidance for Emergency Response

This document provides guidance on how to apply data quality practices to measurements and information collected during the response and recovery to a radiological release. The process of applying data quality practices to measurement data is called data assessment. All data quality practices applied during a radiological incident response must balance the rigorous and time-consuming process normally applied to, for example, site decommissioning and decontamination, with the time- and resource-constraints present during emergency response. The guidance in this document presents the application of data quality practices for data assessment in a graded approach, where the recommended rigor increases as the response continues through its phases and as time and resource constraints relax.

54 ENVIRONMENTAL SCIENCES↗

Recommendations for Radiological Data Assessment Implementation

Since thorough verification, validation, and data quality assessment (DQA) processes may delay incident commanders and elected and appointed officials from making key decisions, the U.S. Department of Homeland Security (DHS) National Urban Security Technology Laboratory (NUSTL) tasked Pacific Northwest National Laboratory (PNNL) to develop tools and guidance for the federal, state, local, tribal, and territorial (FSLTT) responders using research, discussions with select FSLTT responders, and the experiences of subject matter experts in incident response. This report provides NUSTL with recommendations on best practices for verification, validation, and data quality assessment for the data collected by responders during a radiological or nuclear event. The purpose of this report is to inform the development of a DQA toolkit aimed at the needs of data assessors during the response to a radiological incident.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

CBRN Situational Awareness Tools for the Modern Age

CBRN Situational awareness (SA) should be a key operational requirement in the CNI area of discussion, not only for the “boots-on-the-ground” warfighter, but at a strategic level. For example, maneuver plans will need to be developed for contamination avoidance and battlefield survivability. Large datasets from instruments dispersed across the battlefield will thus need to be collected and processed into a holistic assessment of the radiological hazard. From there, hazard maps then must be distributed at the tactical level, all while continuing to effectively engage a peer adversary. This vision represents a network of sensors, software tools, data processing algorithms, communications suites, and common operational picture (COP) platforms working in concert to inform warfighters and command echelons alike of evolving nuclear and radiological hazards. This complex system-of-systems and the ultimate goal of effective engagement in a nuclear or radiological-hazard battlefield can be achieved through pursuit of improvement in collaborative SA tools.

Becker, Eric M.↗

Survey of Technologies to Meet PAG limits for Detection of Cesium-137 in Water

The goal of this report is to evaluate the process of adding a sorbent to the sampling process to preconcentrate Cs-137 and then analyze the sorbent to provide a rapid assessment of results to guide decisions on drinking water sources and the protection of the public. Multiple unit design variables were considered: sample configuration/geometry, sorbent efficiency, sample volume. Model simulations demonstrated through these unit design efficiencies that 10 L of sample volume processed through a sorbent provides nearly two orders of magnitude improvement in sample counting time to provide results to a decision maker than the current process. Over 60 publications and reports concerning Cs-137 and sorbents were evaluated. The key attributes were readiness of sorbent to be deployed in a mobile laboratory environment, and minimum sample preparation and conditioning. Examples of sorbents not considered further included nanomaterials, which have not been evaluated at a commercial scale and are limited in availability. The recommended sorbents for further consideration include: ferrocyanide salts, zeolite, and chemically modified granular activated carbon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

135 Xe measurements with a two-element CZT-based radioxenon detector for nuclear explosion monitoring

Measurement of elevated concentrations of xenon radioisotopes ( 131m Xe, 133m Xe, 133 Xe and 135 Xe) in the atmosphere has been shown to be a very powerful method for verifying whether or not a detected explosion is nuclear in nature. These isotopes are among the few with enough mobility and with half-lives long enough to make their detection at long distances realistic. Existing radioxenon detection systems used by the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) suffer from problems such as complexity, need for high maintenance and memory effect. To study the response of CdZnTe (CZT) detectors to xenon radioisotopes and investigate whether it is capable of mitigating the afore-mentioned issues with the current radioxenon detection systems, a prototype detector utilizing two coplanar CZT detectors was built and tested at Oregon State University. The detection system measures xenon radioisotopes through beta-gamma coincidence technique by detecting coincidence events be-tween the two detectors. Here in this paper, we introduce the detector design and report our measurement results with radioactive lab sources and 135 Xe produced in the OSU TRIGA reactor. Minimum Detectable Concentration (MDC) for 135 Xe was calculated to be 1.47 ± 0.05 mBq/m 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unattended Sensor System With CLYC Detectors

We have developed a next-generation unattended sensor for detecting anomalous radiation sources. The system combines several technologies to reduce size and weight, increase battery lifetime, and improve decision-making capabilities. Sixteen Cs2LiYCl6:Ce (CLYC) scintillators allow for gamma-ray spectroscopy and neutron detection in the same volume. Low-power electronics for readout, high voltage bias, and digital processing reduce the total operating power to 1.3 W. Computationally efficient analysis algorithms perform spectral anomaly detection and isotope identification. When an alarm occurs, the system transmits alarm information over a cellular modem. In this paper, we describe the overall design of the unattended sensor, present characterization results, and compare the performance to stock NaI:Tl and 3He detectors.

CLYC↗

A CZT-based radioxenon detection system in support of the Comprehensive Nuclear-Test-Ban Treaty

Here in this work, a prototype radioxenon detection system was designed, developed and tested at Oregon State University to study the response of CdZnTe (CZT) detectors to xenon radioisotopes for monitoring nuclear explosions. The detector utilizes two coplanar CZT detectors and measures xenon radioisotopes through beta-gamma coincidence detection between the two detection elements. The CZT-based detection system offers excellent energy resolution and background count rate compared with scintillator-based beta-gamma coincidence detectors currently in operation at the IMS stations. In this paper, we briefly discuss the detector design and report our recent measurement results with 131mXe, 133mXe, and 133Xe produced in the TRIGA reactor at OSU.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance Characteristics of Pixelated CZT Crystals used on the GammaTracker Project

GammaTracker is a handheld radioisotope identification device in development at Pacific Northwest National Laboratory that uses eighteen pixelated Cadmium-Zinc Telluride (CZT) crystals to provide energy resolution approaching that of high-purity germanium without the need for cryogenic cooling. Additionally, these crystals can be used to provide directional and imaging capabilities that cannot be found in other handheld detectors. A significant number of CZT crystals have been procured during the development of the GammaTracker system; the majority of these were procured with the same set of specifications. Each of these detectors has been characterized in terms of key parameters, including current-voltage response and pixel-by-pixel energy resolution. The results of this testing indicate that the overall quality of CZT crystals is improving over time.

Becker, Eric M.↗