TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25
The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.