Engineering Papers⌕ Search

Engineering topics

Beaumont, Paul R.

Publications and source records attributed to Beaumont, Paul R..

Isotope exchange of ND 3 on Pt catalyst-loaded 13X molecular sieve

During D-T fusion operations the capture, purification, and recycling of unburned tritium will be crucial, as the formation of tritium containing molecules require additional processing. Here, removing the tritium can require costly processing to be unbound from the tritium-containing molecules and improvements to these processes will be necessary moving forward. Existing techniques using sorbent material beds to remove tritium-containing molecules from process gas streams undergo repeated high-heat cycling which leads to diminished bed lifespans, necessitating replacement and associated downtime. This work demonstrates the capture and isotopic exchange technique of deuterated ammonia (ND3), used as a surrogate for tritium, at ambient temperature using a Pt catalyst-loaded 13X molecular sieve. Unmodified 13X molecular sieve is capable of adsorbing and retaining the ND3 however, incorporation of a catalyst facilitates the isotopic exchange of the hydrogen isotopes. The effluent gas streams were analyzed in conjunction with desorbed ammonia isotopologues post-exchange to verify these results. Isotopically exchanging and removing heavier hydrogen isotopes using this technique provides an alternative to traditional removal methods.

08 HYDROGEN↗

Isotope Exchange of ND 3 on Pt Catalyst–Loaded 5A Molecular Sieve

Recollecting and purifying unburned tritium is a preferred process for D-T fusion operations. However, tritium containing byproducts act as a potential holdup for the material, requiring additional processing to liberate the tritium. Furthermore, using deuterium as a surrogate for tritium, this work demonstrates the capture and isotope exchange of deuterated ammonia using a Pt catalyst–loaded 5A molecular sieve, performed at ambient temperatures, verified by the analysis of the effluent gas streams and desorbed ammonia isotopologues post exchange.

5A↗

Patterning of magneto-optical nanomaterials

Patterning of colloidal particles in precisely organized architectures has attracted intense research interest for decades. This is due to their potential applications in flexible electronics, magnetic and optical devices, sensors, biotechnology, communications, etc. However, creation of mesoscale assemblies at commercial scales have received less attention. The mesoscale systems reside between the micro- and macroscopic scales, with length dimensions from ≈ 100 µm to 5 mm. By leveraging decades of experimental and theoretical research in nanomaterial fields, we were able to precisely create and control the placement of nanoscale materials, allowing us to create mesoscale materials. We developed a versatile and automatic mesoscale patterning technology (via SEM-FIB and 3D printing) that provides precise and consistent control and special arrangement of functional nanomaterials. The versatility of the strategy is demonstrated by patterning nanoparticles with different dimensions, shapes and compositions, tethered with various functionalities and subjected to different external stimuli.

42 ENGINEERING↗

Tritium cleanup system and method

Work area cleanup systems and methods are described for removing tritium from the atmosphere of a work area such as inert gas gloveboxes. Systems utilize a multi-column approach with parallel processing. Tritium of a tritium-contaminated stream is converted into tritiated water and adsorbed onto the separation phase of a first column as a second, parallel column can be simultaneously regenerated. The gaseous stream that exits the column during the regeneration phase can carry a high tritium concentration. The system can also include and a separation stage during which the tritium of the gaseous regeneration stream can be separated from the remainder of the regeneration product.

Xiao, Xin↗

Evaluation of Detritiation Strategies for Mitigating Tritium Releases

Tritium confinement is performed using different barriers to minimize releases to the environment. Primary confinement is usually performed by process piping and components, secondary confinement typically by inerted gloveboxes connected to a continuously operating tritium stripper system. Some facility designs employ tertiary tritium confinement by using process room confinement with a tritium stripper system activated after an accident to further mitigate tritium releases to the environment. Secondary confinement of some tritium systems such as radiation-hardened or shielded-cell enclosures are not easily achieved using designs for inerted glovebox. These enclosures can be challenging to seal for secondary tritium confinement due to heating, ventilation, and air conditioning (HVAC) needs for temperature control, as well as feedthroughs for equipment and instrumentation, are potential pathways for tritium leaks or loses. Additional tritium leak paths can be created in secondary confinement enclosures due to a Design Basis Accident (DBA) seismic event. These new, larger tritium leak rates from the DBA event are usually not part of the stripper system design basis so all tritium released to the secondary confinement enclosure is assumed released to the environment. Detritiation strategies for shielded enclosures and/or gloveboxes with significant leak rates are necessary to minimize off-site radiological dose consequences. To address this, the relationship between the confinement system leak rate and stripper system (recirculating) flow rate was evaluated to meet prescribed maximum allowable environmental tritium emissions from the event. The simple analysis described assumes a constant leak rate from the confinement system (i.e. shielded enclosure or glovebox) while a recirculating stripper system strips tritium from the system– a competition between tritium release and tritium recovery. At a high level, the resulting expression summarizes the relationship between system leak rate (F L ) and stripper flow rate (F S ) relative to allowable tritium release (Q A ) and initial tritium release (Q 0 ): $\frac{F_L}{F_s}$ ≈ $\frac{Q_A}{Q_0}$. This report derives the relationship between these parameters, examines the impact of finite stripping times followed by purging of the stripped volume. The analysis provides example results for up to 30 gram tritium releases: the maximum tritium inventory of a Hazard Category III (Department of Energy) Nuclear Facility. The detritiation model presented represents a high-level analysis of tritium recovery versus losses for “leaky” confinement enclosures such as shielded cells after large tritium releases. Key parameters for doing the analyses are the system leak rate, stripper flow rate, initial tritium release, and allowable tritium release values. The analyses show a proportional decrease in releases with reduction in initial tritium release but a non-linear increase in tritium recovery with increased stripper flow rate or reduced leak-rate. The analyses also apply to glovebox confinement systems which could have significant increases in leak rates after a DBA. The analysis recognizes but does not include tritium absorption followed by re-emission from the walls of the confinement volume – an analysis which could be pursued in future studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Isotope separation methods and systems

Methods and systems for the separation of isotopes from an aqueous stream are described as can be utilized in one embodiment to remove and recover tritium from contaminated water. Methods include counter-current flow of an aqueous stream on either side of a separation membrane. The separation membrane includes an isotope selective layer (e.g., graphene) and an ion conductive supporting layer (e.g., Nafion®). An electronic driving force encourages passage of isotopes selectively across the membrane to enrich the flow in the isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Future Recovered Gas Dryer Development (SRTE FY2019 PRDR SR19009)

A manifold was designed and constructed to evaluate the isotopic exchange of deuterium for hydrogen using Pt catalyzed zeolites, deuterated water, and deuterated ammonia. Using varying catalytic loadings on the 5A substrate and real-time RGA monitoring of the effluent stream, isotopic exchange was successfully demonstrated between H 2 and D 2 O or ND 3 . The catalytic isotopic exchange was further verified when compared against an uncatalyzed sample of zeolite, demonstrating little-to-no activity. Based on the experiments performed here, the removal of tritium from tritiated water and tritiated ammonia is possible for future RGD beds using a Pt catalyzed zeolite. Work is still ongoing with the planned manifold improvements and scheduled testing of other catalyzed zeolite substrates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Metal Bellows Valve Reliability Testing

Swagelok B ® series metal bellows-sealed valves were tested for their cycle performance longevity to evaluate their use in tritium service. The valves selected differed in the size of their pneumatic actuator and the stem tip material. Valves tested had one of three actuator sizes (1C, 3C, or 5C) and one of two stem tip materials: a cobalt-based metal, Stellite™, and a polyimide material, Vespel ® . An automated valve manifold was constructed, allowing for the simultaneous cycling of a total of 10 valves. Automation controls allowed for user inputs, controlling the number of valve cycles per test and the number of tests per experiment. Valves installed on the valve testing manifold to be cycled following a valve frequency test plan. After a defined number cycles, the valves would undergo leak testing using an inline leak detector. The inline helium leak detector provided qualitative detection of any failing or failed valves. If a valve had failed, a leak rate greater than at 1.0 x 10 -7 std cc He/sec, the valve would be removed from the manifold and quantitative leak rate measurements made. After specific cycling milestones were reached, quantitative valve leak rate measurements were performed to assess the adequacy of the qualitative measurement method. Valve evaluation began with initial leak tests: valve inlet/outlet seat rates and total body leak rate. The as received 1C valves, with PTFE stem tips, passed initial leak tests; however, stem tips replacements with either metal or polyimide stem tips essentially created valves which failed subsequent leak tests and were not subject to valve cycling. The 3C actuated valves had been cycled 150,000 times, resulting in 60% of the Stellite™ and Vespel ® tipped valves still passing the leak rate criteria. Failure analysis on the other 40% has yet to be conducted. Eight of the 5C valves had reached 150,000 cycles with 80% of the valves passing the leak rate criteria: two Vespel ® tipped 5C valves failed leak rate testing after 120,000 cycles.

36 MATERIALS SCIENCE↗