Engineering PapersSearch

Engineering topics

Batelaan, P. D.

Publications and source records attributed to Batelaan, P. D..

Search for water in Comet P/Halley at 380 GHz

A search for the 4(14)-3(21) orthorotational transition of H2O near 380 GHz was conducted in the coma of Comet P/Halley on May 6, 1986 using a heterodyne receiver and a high resolution spectrometer on the NASA Kuiper Airborne Observatory (KAO). A measured upper limit flux density in a 2 MHz bandwidh was obtained. Model calculations, including both collisions and infrared vibrational excitation by the solar radiation flux, show that this upper limit corresponds to an upper limit on the water production rate of 1.5 x 10 to the 30th water molecules per second for an isothermal coma at 200 K and 1.5 x 10 to the 31st/s for a more realistic model of the coma.

Gulkis, S.

A large-aperture space telescope for infrared and submillimeter astronomy

The Large Aperture Telescope (LAT), which will have a diameter of 10-30 m and will operate in the 2-1000 micron wavelength range, is described. It is noted that the LAT could be carried into orbit with a single launch of the Space Transportation System and semiautomatically deployed as a free flyer with a nominal 10-yr mission duration. Servicing and instrument changes would be made at 2-yr intervals. It is pointed out that the LAT would have to be placed above the earth's atmosphere to avoid both the absorption that occurs through much of the infrared and submillimeter and the turbulence which limits spatial resolution. Important technical considerations for the LAT are discussed; they include the telescope optical form, the primary mirror material, figure control techniques, the deployment techniques, and thermal control. The science objectives and rationale for the LAT are discussed and various hardware techniques and concepts for its implementation are described.

Murphy, J. P.

DSN water vapor radiometer: Tropospheric range delay calibration

A discussion is presented of the Deep Space Network water vapor radiometer by means of simultaneous antenna temperature and radiosonde measurements at Edwards Air Force Base. The calibration of radiometer gain and hot load radiometric noise temperature is also described. Calibration equations are given. It is found that with a selected data set, the RMS error is less than 1 cm over a total delay range of 9 to 38 cm. Limitations on the use of the water vapor radiometer are also given.

Slobin, S. D.

DSN water vapor radiometer development: Recent work, 1978

A water vapor radiometer (WVR) was developed that measures the atmospheric noise temperature at two different frequencies near 22 GHz. These noise temperature are used in empirical-theoretical equations that yield tropospheric range delay, in centimeters, through the atmosphere along the beam of the WVR. This range correction is then applied, as needed, to measurements concerning spacecraft range and to VLBI baseline determinations. The WVR design and calibration techniques are discussed.

Batelaan, P. D.

Absolute flux density calibrations of radio sources: 2.3 GHz

A detailed description of a NASA/JPL Deep Space Network program to improve S-band gain calibrations of large aperture antennas is reported. The program is considered unique in at least three ways; first, absolute gain calibrations of high quality suppressed-sidelobe dual mode horns first provide a high accuracy foundation to the foundation to the program. Second, a very careful transfer calibration technique using an artificial far-field coherent-wave source was used to accurately obtain the gain of one large (26 m) aperture. Third, using the calibrated large aperture directly, the absolute flux density of five selected galactic and extragalactic natural radio sources was determined with an absolute accuracy better than 2 percent, now quoted at the familiar 1 sigma confidence level. The follow-on considerations to apply these results to an operational network of ground antennas are discussed. It is concluded that absolute gain accuracies within + or - 0.30 to 0.40 db are possible, depending primarily on the repeatability (scatter) in the field data from Deep Space Network user stations.

Freiley, A. J.

DSN water vapor radiometer development: Recent work

A water vapor radiometer (WVR) was developed which measures the atmospheric noise temperature at two different frequencies. These noise temperatures are used in empirical-theoretical equations which yield tropospheric range delay, in centimeters, through the atmosphere along the beam of the WVR. This range correction is then applied to measurements concerning spacecraft range and to very long baseline interferometry determinations.

Slobin, S. D.

A demonstration of a transportable radio interferometric surveying system with 3-cm accuracy on a 307-m base line

A precision geodetic measurement system (Aries, for Astronomical Radio Interferometric Earth Surveying) based on the technique of very long base line interferometry has been designed and implemented through the use of a 9-m transportable antenna and the NASA 64-m antenna of the Deep Space Communications Complex at Goldstone, California. A series of experiments designed to demonstrate the inherent accuracy of a transportable interferometer was performed on a 307-m base line during the period from December 1973 to June 1974. This short base line was chosen in order to obtain a comparison with a conventional survey with a few-centimeter accuracy and to minimize Aries errors due to transmission media effects, source locations, and earth orientation parameters. The base-line vector derived from a weighted average of the measurements, representing approximately 24 h of data, possessed a formal uncertainty of about 3 cm in all components. This average interferometry base-line vector was in good agreement with the conventional survey vector within the statistical range allowed by the combined uncertainties (3-4 cm) of the two techniques.

Ong, K. M.

Improved noise-adding radiometer for microwave receivers

Use of input switch and noise reference standard is avoided by using noise-adding technique. Excess noise from solid state noise-diode is coupled into receiver through directional coupler and square-wave modulated at low rate. High sensitivity receivers for radioastronomy applications are utilized with greater confidence in stability of radiometer.

Batelaan, P. D.