Engineering Papers⌕ Search

Engineering topics

Bartolini, M.

Publications and source records attributed to Bartolini, M..

137 records · Page 8

Performance of the Muon g - 2 calorimeter and readout systems measured with test beam data

A single calorimeter station for the Muon $g-2$ experiment at Fermilab includes the following subsystems: a 54-element array of PbF$_{2}$ Cherenkov crystals read out by large-area SiPMs, bias and slow-control electronics, a suite of 800 MSPS waveform digitizers, a clock and control distribution network, a gain calibration and monitoring system, and a GPU-based frontend read out through a MIDAS data acquisition environment. The entire system performance was evaluated using 2.5 - 5 GeV electrons at the End Station Test Beam at SLAC. This paper includes a description of the individual subsystems and the results of measurements of the energy response and resolution, energy-scale stability, timing resolution, and spatial uniformity. All measured performances meet or exceed the $g-2$ experimental requirements. Based on the success of the tests, the complete production of the required 24 calorimeter stations has been made and installation into the main experiment is complete. Furthermore, the calorimeter response measurements determined here informed the design of the reconstruction algorithms that are now employed in the running $g-2$ experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of C P Violation in Charm Decays

A search for charge-parity $(CP)$ violation in $D^0 → K^–K^+$ and $D^0 → π^–π^+$ decays is reported, using $p p$ collision data corresponding to an integrated luminosity of 5.9 fb –1 collected at a center-of-mass energy of 13 TeV with the LHCb detector. The flavor of the charm meson is inferred from the charge of the pion in $D^*(2010)^+ → D^0π^+$ decays or from the charge of the muon in $\overline B → D^0μ^–\overline ν_μX$ decays. The difference between the $CP$ asymmetries in $D^0 → K^–K^+$ and $D^0 → π^–π^+$ decays is measured to be $ΔA_{CP} = [–18.2 ± 3.2($stat$) ± 0.9($syst$)] × 10^{–4}$ for $π$-tagged and $ΔACP = [–9 ± 8($stat$) ± 5($syst$)] × 10^{–4}$ for $μ-$ tagged $D^0$ mesons. Combining these with previous LHCb results leads to $ΔA_{CP} = (–15.4 ± 2.9) × 10^{–4}$, where the uncertainty includes both statistical and systematic contributions. The measured value differs from zero by more than 5 standard deviations. This is the first observation of $CP$ violation in the decay of charm hadrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Fermilab Muon g-2 experiment: laser calibration system

The anomalous muon dipole magnetic moment can be measured (and calculated) with great precision thus providing insight on the Standard Model and new physics. Currently an experiment is under construction at Fermilab (U.S.A.) which is expected to measure the anomalous muon dipole magnetic moment with unprecedented precision. One of the improvements with respect to the previous experiments is expected to come from the laser calibration system which has been designed and constructed by the Italian part of the collaboration (INFN). Furthermore, an emphasis of this paper will be on the calibration system that is in the final stages of construction as well as the experiment which is expected to start data taking this year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron beam test of key elements of the laser-based calibration system for the muon g - 2 experiment

We report the test of many of the key elements of the laser-based calibration system for muon g - 2 experiment E989 at Fermilab. The test was performed at the Laboratori Nazionali di Frascati's Beam Test Facility using a 450 MeV electron beam impinging on a small subset of the final g - 2 lead-fluoride crystal calorimeter system. The calibration system was configured as planned for the E989 experiment and uses the same type of laser and most of the final optical elements. We show results regarding the calorimeter's response calibration, the maximum equivalent electron energy which can be provided by the laser and the stability of the calibration system components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗