Engineering Papers⌕ Search

Engineering topics

Barrow, P.

Publications and source records attributed to Barrow, P..

A multi-Physics Experiment for Low-Yield Nuclear Explosion Monitoring

A series of multi-physics experiments, referred to as Physics Experiment 1 (PE1) is underway at the United States’ Nevada National Security Site (NNSS). The PE1 series includes detonations of three underground chemical explosions in P-tunnel, with fully coupled (PE1 A), partially decoupled (PE1 D L ), and fully decoupled (PE1 B) emplacements. Canisters with gas tracers are imbedded in the explosives, and the tracers are released when the canister is destroyed by the detonation. A dedicated electromagnetic (EM) experiment (EMX) generates well-characterized EM signals at an underground location near the chemical explosive experiments. A series of atmospheric experiments (METEX, REACT, and METREX) release smoke and radioactive tracers around Aqueduct Mesa to test gas transport in complex topography. Each of the chemical explosive experiments includes a network of sensors to record seismic, acoustic, and electromagnetic waves, measurement of atmospheric conditions, and air sample collection for measurement of tracer concentration. EMX records EM signals underground and on the surface of Aqueduct Mesa. METEX, REACT, and METREX include measurement of atmospheric condition, as well as tracking smoke releases. REACT and METREX add low-level radioactive gas tracers to the atmospheric releases.

58 GEOSCIENCES↗

Fallon FORGE: Analogue Outcrop Samples

Compilation of results for mechanical and fluid flow properties of analogue outcrop samples - experimental data for compressional and shear wave velocities, tensile strengths, and compressive strengths. Outcrop location and sample orientation data are documented in a separate csv file.

15 GEOTHERMAL ENERGY↗

Search for magnetic inelastic dark matter with XENON100

We present the first search for dark matter-induced delayed coincidence signals in a dual-phase xenon time projection chamber, using the 224.6 live days of the XENON100 science run II. This very distinct signature is predicted in the framework of magnetic inelastic dark matter which has been proposed to reconcile the modulation signal reported by the DAMA/LIBRA collaboration with the null results from other direct detection experiments. No candidate event has been found in the region of interest and upper limits on the WIMP's magnetic dipole moment are derived. The scenarios proposed to explain the DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of WIMPs with masses of 58.0 GeV/c{sup 2} and 122.7 GeV/c{sup 2} are excluded at 3.3 σ and 9.3 σ, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

DARWIN: towards the ultimate dark matter detector

DARk matter WImp search with liquid xenoN (DARWIN) will be an experiment for the direct detection of dark matter using a multi-ton liquid xenon time projection chamber at its core. Its primary goal will be to explore the experimentally accessible parameter space for Weakly Interacting Massive Particles (WIMPs) in a wide mass-range, until neutrino interactions with the target become an irreducible background. The prompt scintillation light and the charge signals induced by particle interactions in the xenon will be observed by VUV sensitive, ultra-low background photosensors. Besides its excellent sensitivity to WIMPs above a mass of 5 GeV/ c {sup 2}, such a detector with its large mass, low-energy threshold and ultra-low background level will also be sensitive to other rare interactions. It will search for solar axions, galactic axion-like particles and the neutrinoless double-beta decay of {sup 136}Xe, as well as measure the low-energy solar neutrino flux with < 1% precision, observe coherent neutrino-nucleus interactions, and detect galactic supernovae. We present the concept of the DARWIN detector and discuss its physics reach, the main sources of backgrounds and the ongoing detector design and R and D efforts.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics reach of the XENON1T dark matter experiment

The XENON1T experiment is currently in the commissioning phase at the Laboratori Nazionali del Gran Sasso, Italy. In this article we study the experiment's expected sensitivity to the spin-independent WIMP-nucleon interaction cross section, based on Monte Carlo predictions of the electronic and nuclear recoil backgrounds. The total electronic recoil background in 1 tonne fiducial volume and (1, 12) keV electronic recoil equivalent energy region, before applying any selection to discriminate between electronic and nuclear recoils, is (1.80 ± 0.15) · 10{sup −4} (kg·day·keV){sup −1}, mainly due to the decay of {sup 222}Rn daughters inside the xenon target. The nuclear recoil background in the corresponding nuclear recoil equivalent energy region (4, 50) keV, is composed of (0.6 ± 0.1) (t·y){sup −1} from radiogenic neutrons, (1.8 ± 0.3) · 10{sup −2} (t·y){sup −1} from coherent scattering of neutrinos, and less than 0.01 (t·y){sup −1} from muon-induced neutrons. The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio method, after converting the deposited energy of electronic and nuclear recoils into the scintillation and ionization signals seen in the detector. We take into account the systematic uncertainties on the photon and electron emission model, and on the estimation of the backgrounds, treated as nuisance parameters. The main contribution comes from the relative scintillation efficiency L{sub eff}, which affects both the signal from WIMPs and the nuclear recoil backgrounds. After a 2 y measurement in 1 t fiducial volume, the sensitivity reaches a minimum cross section of 1.6 · 10{sup −47} cm{sup 2} at m{sub χ} = 50 GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment

The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 286 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗