Engineering Papers⌕ Search

Engineering topics

Bankston, C. P.

Publications and source records attributed to Bankston, C. P..

52 records · Page 3

Pool fires in a simulated aircraft cabin interior with ventilation

Results of experiments conducted at the JPL to evaluate aircraft postcrash fire hazards are presented. The experiments were carried out in a one-third scale simulated aircraft cabin geometry to study pool fire and ventilation flow interactions. It is shown that wind-induced ventilation may significantly affect fire plume orientation, smoke transport, and heat fluxes and thus will affect subsequent fire spread and the immediate survivability of the passengers.

Bankston, C. P.↗

AMTEC electrode development

The Alkali Metal Thermoelectric Converter (AMTEC) is a direct energy conversion device, utilizing a high sodium vapor pressure or activity ratio across a beta-alumina solid electrolyte. Progress is reported on a long life, high power, porous electrode. Two electrode compositions were identified which have the potential for long life operation at power densities above 0.5 W/sq cm. Longer lifetime testing is being initiated. Successful optimization and demonstration of very long lifetimes for these electrodes will be a major step toward establishing the feasibility of AMTEC space power systems.

Bankston, C. P.↗

Alkali metal thermoelectric conversion (AMTEC) technology status review

AMTEC operating principles, technical problems, and recent electrode research results are briefly reviewed. The mechanisms responsible for the degradation of thin-film molybdenum electrodes are discussed, and four alternate high-power electrode compositions and morphologies are identified. Separate self-contained recirculating AMTEC cells have demonstrated 19-percent efficiency, 10,000 hr at high temperature, and multicell operation including series connection. Results of systems studies in the 0.5-100 kWe range indicate that AMTEC performance and operating characteristics make it a strong candidate for future space applications.

Bankston, C. P.↗

Voltammetric studies of porous molybdenum electrodes for the alkali metal thermoelectric converter

Voltammetry of partially oxidized porous molybdenum alkali metal thermoelectric converter (AMTEC) electrodes from about 600 to 1000 K revealed a series of redox processes within the AMTEC operational voltage range which can be used to establish the electronic and ionic conductivities of these electrodes. Improved estimates of the free energies of formation of Na2Mo3O6, NaMoO2, and Na3MoO4 are obtained. Evidence is provided for the slow corrosive attack by Na2MoO4 on molybdenum. The ionic conductivity of Na2MoO4 is found to be sufficiently large at temperatures of greater than 700 K to explain the observed electrochemical phenomena in addition to the enhanced sodium transport in AMTEC electrodes below the freezing point of Na2MoO4.

Williams, R. M.↗

The role of oxygen in porous molybdenum electrodes for the alkali metal thermoelectric converter

A model for chemical reactions in porous molybdenum electrodes is presented which is based on thermochemical and kinetic data, known sodium-molybdenum-oxygen chemistry, X-ray diffraction analysis of molybdenum and molybdenum oxide electrodes, and the electrochemical behavior of the cell. Enhanced sodium transport through the electrode in its optimum performance state is found to be due to the high sodium ion conductivity of molten Na2MoO4 in the pores, and the electrical conduction to the molybdenum matrix by Na2Mo3O6. The decline of electrode performance is shown to be due to a combination of loss mechanisms for the Na-Mo-O compounds including reduction at short circuit, disproportionation of Na2Mo3O6 at open circuit, and the evaporation of Na2MoO4 at elevated temperature. It is suggested that operation of the cell at moderate voltage of about 0.5 V corresponding to maximum power may be a more stable condition for the porous electrode than open-circuit stand or short-circuit, where degradation reactions are heightened.

Williams, R. M.↗

AMTEC: High efficiency static conversion for space power

Future manned and unmanned space missions will require reliable, high efficiency energy conversion systems. For a manned Mars mission, power levels in the range of 10 to 100 kWe will be needed. The Alkali Metal Thermoelectric Converter (AMTEC) is a direct energy conversion technology with the potential to meet these needs. The AMTEC is a thermally regenerative electrochemical device that derives its operation from the sodium ion conducting properties of beta-alumina solid electrolyte (BASE). To date, an efficiency of 19%, area power density of 1 W/sq cm, and a lifetime of 10,000 hours at high temperature were demonstrated in laboratory devices. Systems studies show that projected AMTEC systems equal or surpass the performance of other static or dynamic systems in applications of 1 kWe-1 MWe. Thus, the laboratory experiments and applications studies conducted to date have shown that the AMTEC posseses great potential. In order to bring this technology to the stage where prototype units can be built and operated, several technical issues must be addressed. These include the need for long life, high power electrodes, minimization of radiative parasitic losses, and high temperature seals. In summary, the evidence shows that if AMTEC is developed, it can play a significant role in future space power applications.

Bankston, C. P.↗

Pool fire-ventilation crossflow experiments in a simulated aircraft cabin interior

An experimental facility has been built to study pool fire dynamics and flame spread behavior in a 1/3-scale simulated aircraft interior; attention is presently given to pool fire ventilation crossflow using a 'channel' pool fire subjected to crossflow velocities that replicate postcrash conditions in a wide body aircraft. Crossflow velocity is noted to have a strong effect on visible flame geometry, tilting the flame over sharply. A reverse flow ceiling jet of hot gases was also present in all tests, however, and extended far upstream of the fire, so that despite the appearance of the visible flame, the vertical momentum of the plume was strong enough to establish the reverse flow layer and spread smoke and toxic gases upstream against a significant ventilating flow.

Bankston, C. P.↗

Measurements of the response of transport aircraft ceiling panels to fuel pool fires

Tests were performed to characterize the responses of various aircraft ceiling panel configurations to a simulated post-crash fire. Attention was given to one currently used and four new ceiling configurations exposed to a fuel pool fire in a circulated air enclosure. The tests were controlled to accurately represent conditions in a real fire. The panels were constructed of fiberglass-epoxy, graphite-phenolic resin, fiberglass-phenolic resin, Kevlar-epoxy, and Kevlar-phenolic resin materials. The phenolic resin-backed sheets performed the best under the circumstances, except when combined with Kevlar, which became porous when charred.

Bankston, C. P.↗

Alkali Metal Thermoelectric Conversion (AMTEC) for space nuclear power systems

Performance parameters of the Alkali Metal Thermoelectric Converter (AMTEC) for a 100 kW electric power system have been calculated at four technological levels assuming a heat pipe-cooled nuclear reactor heat source. The most advanced level considered would operate between 1180 K converter temperature and 711 K radiator temperature at 16 percent efficiency, and would weigh 1850 kg with a radiator area of 43 sq m. In addition, electrode research studies for the AMTEC systems have been conducted utilizing an experimental test cell of Bankston et al. (1983) and Mo and several Mo-Ti electrodes. It was found that the Mo-Ti electrodes offered no improvement in lifetime characteristics over the pure Mo electrodes, however, oxygen treatment of a degraded Mo electrode restored its specific power output to 90 percent of its original specific power and maintained this level for 60 hr, thus offering a potential for lifetime stability.

Bankston, C. P.↗

The alkali metal thermoelectric converter /AMTEC/ - A new direct energy conversion technology for aerospace power

A thermally regenerative electrochemical device for the direct conversion of heat to electrical energy, the alkali metal thermoelectric converter (AMTEC), is characterized by potential efficiencies on the order of 15-40% and possesses no moving parts, making it a candidate for space power system applications. Device conversion efficiency is projected on the basis of experimental voltage vs current curves exhibiting power densities of 0.7 W/sq cm and measured electrode efficiencies of up to 40%. Preliminary radiative heat transfer measurements presented may be used in an investigation of methods for the reduction of AMTEC parasitic radiation losses. AMTEC assumes heat input and rejection temperatures of 900-1300 K and 400-800 K, respectively. The working fluid is liquid sodium, and the porous electrode employed is of molybdenum.

Bankston, C. P.↗

Heat transfer from combustion gases to a single row of closely spaced tubes in a swirl crossflow Stirling engine heater

This paper describes an experimental program to determine the heat-transfer characteristics of a combustor and heat-exchanger system in a hybrid solar receiver which utilizes a Stirling engine. The system consists of a swirl combustor with a crossflow heat exchanger composed of a single row of 48 closely spaced curved tubes. In the present study, heat-transfer characteristics of the combustor/heat-exchanger system without a Stirling engine have been studied over a range of operating conditions and output levels using water as the working fluid. Nondimensional heat-transfer coefficients based on total heat transfer have been obtained and are compared with available literature data. The results show significantly enhanced heat transfer for the present geometry and test conditions. Also, heat transfer along the length of the tubes is found to vary, the effect depending upon test condition.

Bankston, C. P.↗

Dish stirling solar receiver combustor test program

The operational and energy transfer characteristics of the Dish Stirling Solar Receiver (DSSR) combustor/heat exchanger system was evaluated. The DSSR is designed to operate with fossil fuel augmentation utilizing a swirl combustor and cross flow heat exchanger consisting of a single row of 4 closely spaced tubes that are curved into a conical shape. The performance of the combustor/heat exchanger system without a Stirling engine was studied over a range of operating conditions and output levels using water as the working fluid. Results show that the combustor may be started under cold conditions, controlled safety, and operated at a constant air/fuel ratio (10 percent excess air) over the required range of firing rates. Furthermore, nondimensional heat transfer coefficients based on total heat transfer are plotted versus Reynolds number and compared with literature data taken for single rows of closely spaced tubes perpendicular to cross flow. The data show enhanced heat transfer for the present geometry and test conditions. Analysis of the results shows that the present system meets specified thermal requirements, thus verifying the feasibility of the DSSR combustor design for final prototype fabrication.

Bankston, C. P.↗

Aspects of the mechanisms of smoke generation by burning materials

An investigation of smoke generation during the burning of natural and synthetic solid materials (relevant to fire safety problems), under simulated fire conditions, is presented. Smoke formation mechanisms, including flaming and nonflaming combustion, are reviewed, and the complex physical, chemical, and electrical processes, important in smoke particulate production, are identified. With reference to the smoke formation mechanisms, measured experimental data are discussed, and include effects of ventilation gas temperature, dependence on material composition, and chemical analysis of smoke particulates. Significant differences in smoke characteristics are observed between flaming and nonflaming conditions, which is attributed to specific differences in controlling mechanisms and resultant ways leading to particulate formation. The effects of polymer substrate properties and effects of additives for a given substrate on smoke properties are also discussed in terms of basic processes. It is shown that many of the measured trends can be interpreted by considering postulated mechanisms of particulate formation.

Bankston, C. P.↗

Large-scale pool fire test recommendations

The important aspects of external pool fires are outlined. The research objectives are: (1) determine heat flux to surfaces as a function of pool size (convective and radiative heat flux); (2) obtain information that can be compared with theoretical models for radiative flux in the near field; and (3) predict radiative heat flux for arbitrary pool size. The measurements and instrumentation (calorimeters and thermocouples) used for pool fires are outlined.

Bankston, C. P.↗