Transient modeling of an ambient-temperature-source centrifugal-compressor steam-generating heat pump
Not Available
Engineering topics
Publications and source records attributed to Bandhauer, Todd M..
Not Available
A power plant system is disclosed. The power plant system includes a combustor configured, a turbine configured to generate electricity, a heat exchanger and a steam turbine, a carbon capture system configured to remove at least a portion of carbon-based gasses from the flue gas downstream from the heat recovery steam generator, and a thermal storage system including a hot storage unit configured to store thermal energy at a hot temperature, the hot temperature greater than ambient temperature. The power plant is configured to operate in at least a first mode for storing thermal energy in the thermal storage system and a second mode for releasing the stored thermal energy from the thermal storage system and during the second mode, heat stored in the hot storage unit is transferred to the carbon capture system.
As the U.S. grid evolves toward a lower-carbon system, fossil generation assets need to operate in energy markets with high variable renewable energy (VRE) penetration while also decreasing carbon emissions. Current carbon capture and storage (CCS) technologies suffer from high capital cost and an inability to operate flexibly during periods of oscillating demand. The ARPA-E FLECCS Program Phase 1 was created to fund designing and optimizing innovative CCS processes that enable flexibility on a high-VRE grid. To address this need, the Colorado State University (CSU) Team won funding to design a synergized system of thermal energy storage, power generation, and flexible carbon capture to enable breakthrough system performance that achieves an LCOE <$75/MWh with >99% capture rate. This approach will target new or existing natural gas combined cycle power plants. The proposed design utilizes novel hot and cold thermal energy storage (TES) technologies that store low-cost, off-peak electricity as thermal energy to power CCS solvent regeneration and boost plant output during periods of peak demand. The design provides an overall optimized net present value (NPV) by maximizing low carbon power to grid while prices are highest using Storworks Power’s concrete TES technology. The team also capitalizes on decades of ION Clean Energy’s (ION) development in low cost and flexible pioneering solvent technology, which has proven reductions in energy consumption and overall cost of 28% and 38%, respectively, compared with state-of-the-art CCS.
Aspects of the present disclosure include a system for turbo-compression cooling. The system may be aboard a marine vessel. The system includes a power cycle and a cooling cycle. The power cycle includes a first working fluid, a waste heat boiler configured to evaporate the working fluid, a turbine, and a condenser. The condenser condenses the working fluid to a saturated or subcooled liquid. The cooling cycle includes a second working fluid, a first compressor configured to increase the pressure of the second working fluid, a condenser configured to condense the second working fluid to a saturated or subcooled liquid after exiting the first compressor, an expansion valve, and an evaporator. The turbine and first compressor are coupled one to the other. The waste heat boiler receives waste heat from engine jacket water and lubricating oil from a ship service generator. The evaporator cools water in a shipboard cooling loop.
Irrigation accounts for 42% of the total freshwater withdrawals in the United States. Climate change, the pressure of a growing population, degrading water quality, and increased competition from other sectors could constrain continuous supply to meet future agricultural water demand. This study presents an evaluation framework to assess the potential reuse of agricultural drainage water for crop irrigation. Using a regional approach, we review the current state of agricultural drainage treatment and reuse and the institutional, economic, and other barriers that can influence the reuse decision. In the 31 eastern states, agricultural drainage contains valuable nutrients that can be reused for irrigation with minimal treatment, while the 17 western states struggle with large volumes of saline drainage that can contain constituents of concern (e.g., selenium), preventing reuse without treatment. Using a new decision-support tool called WaterTAP3, a potential treatment train for saline agricultural drainage was analyzed to identify treatment challenges, research needs, and the potential implementation at a larger scale. As demonstrated by our case study, desalination of agricultural drainage is costly and energy intensive and will require sizable investments to fully develop and optimize technologies as well as manage the generated waste and brine.
Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.
A highly adsorptive structure includes: a substrate; and a carbon aerogel adhered to the substrate, wherein the carbon aerogel is characterized by having physical characteristics of in-situ formation on the substrate, and wherein the carbon aerogel is configured to selectively adsorb and desorb one or more refrigerants selected from the group consisting of: acid halides, alcohols, aldehydes, amines, chlorofluorocarbons, esters, ethers, fluorocarbons, perfluorocarbons, halocarbons, halogenated aldehydes, halogenated amines, halogenated hydrocarbons, halomethanes, hydrocarbons, hydrochlorofluorocarbons, hydrofluoroethers, hydrofluoroolefins, inorganic gases, ketones, nitrocarbon compounds, noble gases, organochlorine compounds, organofluorine compounds, organophosphorous compounds, organosilicon compounds, oxide gases, refrigerant blends and thiols.
A highly adsorptive structure, includes: a substrate; and a metal-organic framework (MOF) comprising a plurality of metal atoms coordinated to a plurality of organic spacer molecules; wherein the MOF is coupled to at least one surface of the substrate, wherein the MOF is adapted for adsorbing and desorbing a refrigerant under predetermined thermodynamic conditions. The refrigerant includes one or more materials selected from the group consisting of: acid halides, alcohols, aldehydes, amines, chlorofluorocarbons, esters, ethers, fluorocarbons, perfluorocarbons, halocarbons, halogenated aldehydes, halogenated amines, halogenated hydrocarbons, halomethanes, hydrocarbons, hydrochlorofluorocarbons, hydrofluoroethers, hydrofluoroolefins, inorganic gases, ketones, nitrocarbon compounds, noble gases, organochlorine compounds, organofluorine compounds, organophosphorous compounds, organosilicon compounds, oxide gases, refrigerant blends and thiols.
Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.
Microchannel flow boiling is an attractive thermal management strategy for ever-growing volumetric heat dissipation demands associated with electronic systems. Due to difficulties related to measurement at the microscales, the majority of researchers have chosen to study relatively simple situations with uniform heat flux. However, many applications involve local hotspots which give rise to highly non-uniform heat flux and temperature gradients due to heat spreading. This necessitates the consideration of conjugate heat transfer for accurate analysis. The current work is aimed at investigating conjugate heat transfer in a two-phase microchannel array. Experimental data was collected on R134a flow boiling heat transfer for very small hydraulic diameter (<100 µm) silicon microchannels with very high heat fluxes (>1 kW cm -2 ) applied via platinum strip heaters with a footprint size of 1 cm × 1 mm. The collected experimental data was then combined with detailed computational modeling utilizing finite element modeling with COMSOL Multiphysics and MATLAB to examine the applicability of five published heat transfer correlations for use in determining local heat transfer coefficients. A two-phase correlation from Agostini and Bontemps, developed for markedly different test parameters, provided the best computational agreement with an RMS temperature difference from experiment of 3.3 °C and a predicted peak perimeter-averaged heat transfer coefficient of 116 MW m -2 K -1 . Modeling confirms the presence of highly non-uniform local heat flux and correspondingly non-uniform local heat transfer coefficient. Finally, the results of this study make clear the need for better micro-scale two-phase correlations developed to predict local heat transfer coefficients at these small scales and high local heat fluxes.
Packaging high average power laser diode arrays that generate heat at an area average flux in excess of 1 kW·cm -2 is a significant engineering challenge. While liquid microchannel coolers have demonstrated up to 11.9 kW·cm -2 , two-phase microchannel array coolers have not achieved 1 kW cm -2 due to critical heat flux and flow instabilities. In the current study, flow boiling heat transfer was characterized by a 1 × 10 mm heated zone centered over a 5 × 10 mm array of 125 very small channels (45 × 200 μm) with R134a as the phase change fluid. The high aspect ratio channels (4.4:1) were manufactured using MEMS fabrication techniques, which yielded a large heat transfer surface area to volume ratio. A test facility was used to characterize the heat transfer performance of boiling R134a over a range of saturation temperatures (15°C to 25°C), mass fluxes (735-2230 kg·m -2 ·s -1 ), and heat duties (< 110.3 W). During the tests, the calculated outlet vapor quality exceeded 61%, and the base heat flux at the heater reached a maximum of 1.1 kW·cm -2 . The resulting average experimental flow boiling heat transfer coefficients are found to be as large a 13.4 kW·m -2 ·K -1 over the approximately 3 mm two-phase region, with an average uncertainty of ± 2.72%. A substantial amount of heat was spread downstream via the low thermal resistance silicon floor. Specifically, between 29.5% and 55.1% of the heat dissipated in the two-phase region was dissipated over the heater. Finally, the remaining heat dissipated in the two-phase region was dissipated in the 2 mm of channel downstream of the heater. This suggests that heat spreading from the hotspot played a vital role in dissipating the heat load.
Not Available
A thermal management system is integral to a battery pack and/or individual cells. It relies on passive liquid-vapor phase change heat removal to provide enhanced thermal protection via rapid expulsion of inert high pressure refrigerant during abnormal abuse events and can be integrated with a cooling system that operates during normal operation. When a thermal runaway event occurs and sensed by either active or passive sensors, the high pressure refrigerant is preferentially ejected through strategically placed passages within the pack to rapidly quench the battery.
A battery management system with thermally integrated fire suppression includes a multiplicity of individual battery cells in a housing; a multiplicity of cooling passages in the housing within or between the multiplicity of individual battery cells; a multiplicity of sensors operably connected to the individual battery cells, the sensors adapted to detect a thermal runaway event related to one or more of the multiplicity of individual battery cells; and a management system adapted to inject coolant into at least one of the multiplicity of cooling passages upon the detection of the thermal runaway event by the any one of the multiplicity of sensors, so that the thermal runaway event is rapidly quenched.
A system for monitoring parameters of an energy storage system having a multiplicity of individual energy storage cells. A radio frequency identification and sensor unit is connected to each of the individual energy storage cells. The radio frequency identification and sensor unit operates to sense the parameter of each individual energy storage cell and provides radio frequency transmission of the parameters of each individual energy storage cell. A management system monitors the radio frequency transmissions from the radio frequency identification and sensor units for monitoring the parameters of the energy storage system.
An energy storage system having a multiple different types of energy storage and conversion devices. Each device is equipped with one or more sensors and RFID tags to communicate sensor information wirelessly to a central electronic management system, which is used to control the operation of each device. Each device can have multiple RFID tags and sensor types. Several energy storage and conversion devices can be combined.
One of the critical components for the Laser Inertial Fusion Energy (LIFE) power plant is the recovery of tritium from the reactor lithium cooling blanket. In the process proposed by Maroni, high temperature halide salts extract tritium from the lithium using a high-speed centrifugal contactor. Because of high-temperature fluid mixture is very corrosive, this system is not practical. The LIFE team has proposed an alternative process that utilizes a halide-free salt (e.g., LiOH) with a non-centrifuge separation process to extract tritium from the lithium cooling blanket, thus eliminating the need for high-temperature, halide corrosion-resistant materials. To facilitate the design of the contactor and separator, Colorado State University (CSU) was subcontracted by LLNL to conduct the following initial steps in the design process during FY13: • Develop preliminary designs for the separator and Plexiglas models for flow visualization and computational model development, • Select surrogate fluids and flow conditions for the separator, and • Select an appropriate flow visualization fluorescent dye for the surrogate tritium solute.