Initial study on cross-section generation requirements for a PBR equilibrium core

A Serpent model of the equilibrium core HTR-PM small modular nuclear reactor in China, was developed for use in cross-section preparation studies in order to guide methods development for the Griffin reactor multiphysics application. The model includes detailed isotopics for 10 distinct pebble burnup groups in 126 core zones with unique fuel and moderator temperatures obtained from a coupled neutronics-thermal-fluids equilibrium core calculation using Griffin-Pronghorn. A sensitivity study of the fuel and moderator temperatures for various core regions was performed with the MOOSE stochastic tools. The results show that the uncertainties are, not unexpectedly, dominated by the value of the fluid temperature and that the power level, heat transfer coefficient and effective conduction to neighboring pebbles and fluid constitute, at best, second order effects. The temperature uncertainty range varies from 28 K to 57 K between the core entry and exit planes, respectively, but these values are probably higher. We still have to quantify the significance of these uncertainties in the preparation of cross-sections in future work. In addition, we verified that the effective pebble approximation used in the PEBBED and V.S.O.P. computer codes works well for the preparation of region averaged cross-sections. Nevertheless, there are some discrepancies in the cross-sections when compared to the multi-pebble model, which could affect the prediction of peak values and the depletion calculation. We conclude that is highly desirable for future studies with Griffin to be able to handle both the 'effective' pebble approximation and the multi-pebble approach for various pebble burnup groups. This enables Griffin users with the flexibility to perform higher-fidelity studies. Finally, we initiated the preparation of cross-sections for various core regions from the full core Serpent reference model. We quantified the differences in 26 group cross-sections from infinite domain models versus the full core approach. These reference cross-sections will serve to verify the double heterogeneity, self-shielding, and spectrum-correction methods in Griffin. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

XE-100 modeling and simulation for neutronic analysis in MCNP6.2

XE-100 is a generation IV helium-cooled, graphite-moderated, pebble-bed reactor (HTGR). As part of the pathway toward a conceptually designing and licensing this reactor, an independent Monte Carlo model was created in MCNP6.2, and several distinct neutronic analyses were then performed. The double heterogeneity of TRISO fuel within graphite pebbles introduces unique modeling challenges related to particle and pebble clipping. The results show that for neutron and photon heating of ex-core components such as the reflector, RCSS, core barrel (CB), the model that contains clipping produces higher heating values. It is therefore concluded that removing clipping via compression of the particles and pebbles within the model distributes the neutrons and gammas preferentially toward the core center, and reduces the heating that is experienced toward the reactor periphery. Thus, the most conservative model for ex-core heating contains particle and pebble clipping. Also presented are results on the impact of chamfers that exist on the corners of graphite reflector blocks. As these chamfers could potentially create streaming paths, the neutron and gamma flux from the core to the CB were analyzed. It was determined that the chamfers do not significantly impact the neutron or gamma signatures on the CB, in that the shape of the neutron and photon flux on a detector imposed on the CB shows no preferential streaming path. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal and Mechanical Energy Performance Analysis of Closed-loop Systems in Hot-Dry-Rock and Hot-Wet-Rock Reservoirs

To understand the potential and limitations for recovering thermal and mechanical energy from closed-loop geothermal systems a collaborative study is underway that will investigate an array of system configurations, working fluids, geothermal reservoir characteristics, operational periods, and heat transfer enhancements. Closed-loop geothermal systems are distinguished from hydrothermal or enhanced geothermal systems (EGS) in that the working fluid only circulates through drilled boreholes. Principal objectives of this study are to determine upper limits for thermal and mechanical energy recovery and optimal operational and configuration parameters for each scenario. Teams of scientists and engineers are applying a suite of numerical simulation and analytical tools to model the heat recovery from closed-loop geothermal systems, and then optimizing operational and configuration parameters to maximize the thermal and mechanical energy recovery. Results from the suite of numerical simulators and analytical tools, such as outlet and inlet states and temperature profiles in the geothermal reservoir over time are intercompared to increase confidence in the analysis. This paper documents the study findings for closed-loop systems in hot-dry-rock and hot-wet-rock reservoirs, where water is the working fluid. The characteristics of the hot-dry-rock reservoir were based on the U.S. Department of Energy's Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site, near Milford Utah. Two objective functions are defined to optimize the operational and configuration parameters of the system, one each for the recovery of mechanical and thermal energy over the period of operation. For both objective functions, a surface plant thermal to mechanical energy conversion factor and an energy drilling cost is required. In keeping with the study objectives the surface plant conversion factor is determined from a second-law of thermodynamics analysis of a generic binary plant, and drilling costs are based on those from the Utah FORGE site and current national electrical costs.