Engineering Papers⌕ Search

Engineering topics

Baker, Stuart A.

Publications and source records attributed to Baker, Stuart A..

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Optical Relays for Imaging Scintillators

Presentation at the "Multi-Probe Radiography IV: Detectors and Image Analysis" workshop, to be held at LANL, in the Rosen Auditorium. Host is Bob Reinovsky, LANL, 505-699-1127. LANL Point of Contact: Mariana Alvarado Alvarez, LANL, 505-665-7994.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗