Engineering Papers⌕ Search

Engineering topics

Bajt, S.

Publications and source records attributed to Bajt, S..

At least 19 records

Time-Resolved XUV Opacity Measurements of Warm Dense Aluminum

The free-free opacity in plasmas is fundamental to our understanding of energy transport in stellar interiors and for inertial confinement fusion research. However, theoretical predictions in the challenging dense plasma regime are conflicting and there is a dearth of accurate experimental data to allow for direct model validation. Here we present time-resolved transmission measurements in solid-density Al heated by an XUV free-electron laser. We use a novel functional optimization approach to extract the temperaturedependent absorption coefficient directly from an oversampled pool of single-shot measurements, and find a pronounced enhancement of the opacity as the plasma is heated to temperatures of order of the Fermi energy. Plasma heating and opacity enhancement are observed on ultrafast timescales, within the duration of the femtosecond XUV pulse. We attribute further rises in the opacity on ps timescales to melt and the formation of warm dense matter

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extreme ultraviolet resonant inelastic X-ray scattering (RIXS) at a seeded free-electron laser

In the past few years, we have been witnessing an increased interest for studying materials properties under non-equilibrium conditions. Several well established spectroscopies for experiments in the energy domain have been successfully adapted to the time domain with sub-picosecond time resolution. Here we show the realization of high resolution resonant inelastic X-ray scattering (RIXS) with a stable ultrashort X-ray source such as an externally seeded free electron laser (FEL). We have designed and constructed a RIXS experimental endstation that allowed us to successfully measure the d-d excitations in KCoF 3 single crystals at the cobalt M 2,3-edge at FERMI FEL (Elettra-Sincrotrone Trieste, Italy). The FEL-RIXS spectra show an excellent agreement with the ones obtained from the same samples at the MERIXS endstation of the MERLIN beamline at the Advanced Light Source storage ring (Berkeley, USA). We established experimental protocols for performing time resolved RIXS experiments at a FEL source to avoid X ray-induced sample damage, while retaining comparable acquisition time to the synchrotron based measurements. Finally, we measured and modelled the influence of the FEL mixed electromagnetic modes, also present in externally seeded FELs, and the beam transport with ~120 meV experimental resolution achieved in the presented RIXS setup.

36 MATERIALS SCIENCE↗

Ceramic micro-injection molded nozzles for serial femtosecond crystallography sample delivery

Serial femtosecond crystallography (SFX) using X-ray Free-Electron Lasers (XFELs) allows for room temperature protein structure determination without evidence of conventional radiation damage. In this method, a liquid suspension of protein microcrystals can be delivered to the X-ray beam in vacuum as a micro-jet, which replenishes the crystals at a rate that exceeds the current XFEL pulse repetition rate. Gas dynamic virtual nozzles produce the required micrometer-sized streams by the focusing action of a coaxial sheath gas and have been shown to be effective for SFX experiments. Here, we describe the design and characterization of such nozzles assembled from ceramic micro-injection molded outer gas-focusing capillaries. Trends of the emitted jet diameter and jet length as a function of supplied liquid and gas flow rates are measured by a fast imaging system. The observed trends are explained by derived relationships considering choked gas flow and liquid flow conservation. Finally, the performance of these nozzles in a SFX experiment is presented, including an analysis of the observed background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluence thresholds for grazing incidence hard x-ray mirrors

X-ray Free Electron Lasers (XFELs) have the potential to contribute to many fields of science and to enable many new avenues of research, in large part due to their orders of magnitude higher peak brilliance than existing and future synchrotrons. To best exploit this peak brilliance, these XFEL beams need to be focused to appropriate spot sizes. However, the survivability of X-ray optical components in these intense, femtosecond radiation conditions is not guaranteed. As mirror optics are routinely used at XFEL facilities, a physical understanding of the interaction between intense X-ray pulses and grazing incidence X-ray optics is desirable. We conducted single shot damage threshold fluence measurements on grazing incidence X-ray optics, with coatings of ruthenium and boron carbide, at the SPring-8 Angstrom compact free electron laser facility using 7 and 12 keV photon energies. The damage threshold dose limits were found to be orders of magnitude higher than would naively be expected. The incorporation of energy transport and dissipation via keV level energetic photoelectrons accounts for the observed damage threshold.

43 PARTICLE ACCELERATORS↗

Electronic damage in S atoms in a native protein crystal induced by an intense X-ray free-electron laser pulse

Current hard X-ray free-electron laser (XFEL) sources can deliver doses to biological macromolecules well exceeding 1 GGy, in timescales of a few tens of femtoseconds. During the pulse, photoionization can reach the point of saturation in which certain atomic species in the sample lose most of their electrons. This electronic radiation damage causes the atomic scattering factors to change, affecting, in particular, the heavy atoms, due to their higher photoabsorption cross sections. Here, it is shown that experimental serial femtosecond crystallography data collected with an extremely bright XFEL source exhibit a reduction of the effective scattering power of the sulfur atoms in a native protein. Quantitative methods are developed to retrieve information on the effective ionization of the damaged atomic species from experimental data, and the implications of utilizing new phasing methods which can take advantage of this localized radiation damage are discussed.

Galli, L.↗

Fabrication of wedged multilayer Laue lenses

We present a new method to fabricate wedged multilayer Laue lenses, in which the angle of diffracting layers smoothly varies in the lens to achieve optimum diffracting efficiency across the entire pupil of the lens. This was achieved by depositing a multilayer onto a flat substrate placed in the penumbra of a straight-edge mask. The distance between the mask and the substrate was calibrated and the multilayer Laue lens was cut in a position where the varying layer thickness and the varying layer tilt simultaneously satisfy the Fresnel zone plate condition and Bragg’s law for all layers in the stack. This method can be used to extend the achievable numerical aperture of multilayer Laue lenses to reach considerably smaller focal spot sizes than achievable with lenses composed of parallel layers.

42 ENGINEERING↗

Status of the Stardust ISPE and the Origin of Four Interstellar Dust Candidates

Some bulk properties of interstellar dust are known through infrared and X-ray observations of the interstellar medium. However, the properties of individual interstellar dust particles are largely unconstrained, so it is not known whether individual interstellar dust particles can be definitively distinguished from interplanetary dust particles in the Stardust Interstellar Dust Collector (SIDC) based only on chemical, mineralogical or isotopic analyses. It was therefore understood from the beginning of the Stardust Interstellar Preliminary Examination (ISPE) that identification of interstellar dust candidates would rest on three criteria - broad consistency with known extraterrestrial materials, inconsistency with an origin as secondary ejecta from impacts on the spacecraft, and consistency, in a statistical sense, of observed dynamical properties - that is, trajectory and capture speed - with an origin in the interstellar dust stream. Here we quantitatively test four interstellar dust candidates, reported previously [1], against these criteria.

Westphal, A. J.↗

Constraints on the Interstellar Dust Flux Based on Stardust at Home Search Results

Recent advances in active particle selection in the Heidelberg Van de r Graaf (VdG) dust accelerator have led to high-fidelity, low-backgro und calibrations of track sizes in aerogel as a function of particle size and velocity in the difficult regime above 10 km sec..1 and sub micron sizes. To the extent that the VdG shots are analogs for inters tellar dust (ISD) impacts, these new measurements enable us to place preliminary constraints on the ISD flux based on Stardust@home data.

Zolensky, Michael E.↗

Identification of Impact Craters in Foils from the Stardust Interstellar Dust Collector

The Stardust Interstellar Dust Collection tray provides the first opportunity for the direct laboratory-based measurement of contemporary interstellar dust. The total exposed surface of the tray was approximately 0.1 square meters, including 153 square centimeters of Al foil in addition to the silica aerogel tiles that are the primary collection medium. Preliminary examination of aerogel tiles has already revealed 16 tracks from particle impacts with an orientation consistent with an interstellar origin, and to date four of the particles associated with these tracks have a composition consistent with an extraterrestrial origin. Tentative identification of impact craters on three foil samples was also reported previously. Here we present the definitive identification of 20 impact craters on five foils.

Stroud, R. M.↗

A New View on Interstellar Dust - High Fidelity Studies of Interstellar Dust Analogue Tracks in Stardust Flight Spare Aerogel

In 2000 and 2002 the Stardust Mission exposed aerogel collector panels for a total of about 200 days to the stream of interstellar grains sweeping through the solar system. The material was brought back to Earth in 2006. The goal of this work is the laboratory calibration of the collection process by shooting high speed [5 - 30km/s] interstellar dust (ISD) analogues onto Stardust aerogel flight spares. This enables an investigation into both the morphology of impact tracks as well as any structural and chemical modification of projectile and collector material. First results indicate a different ISD flux than previously assumed for the Stardust collection period.

Zolensky, Michael E.↗

FTIR Analysis of Aerogel Keystones from the Stardust Interstellar Dust Collector: Assessment of Terrestrial Organic Contamination and X-Ray Microprobe Beam Damage

The Stardust Interstellar Dust Collector (SIDC) was intended to capture and return contemporary interstellar dust. The approx.0.1 sq m collector was composed of aerogel tiles (85% of the collecting area) and aluminum foils and was exposed to the interstellar dust stream for a total exposure factor of 20 sq m day. The Stardust Interstellar Preliminary Examination (ISPE) is a consortium-based project to characterize the collection using nondestructive techniques. Sandford et al. recently assessed numerous potential sources of organic contaminants in the Stardust cometary collector. These contaminants could greatly complicate the analysis and interperetation of any organics associated with interstellar dust, particularly because signals from these particles are expected to be exceedingly small. Here, we present a summary of FTIR analyses of over 20 aerogel keystones, many of which contained candidates for interstellar dust.

Zolensky, M. E.↗

Four Interstellar Dust Candidates from the Stardust Interstellar Dust Collector

In January 2006, the Stardust sample return capsule returned to Earth bearing the first solid samples from a primitive solar system body, Comet 81P/Wild2, and a collector dedicated to the capture and return of contemporary interstellar dust. Both collectors were approx. 0.1 sq m in area and were composed of aerogel tiles (85% of the collecting area) and aluminum foils. The Stardust Interstellar Dust Collector (SIDC) was exposed to the interstellar dust stream for a total exposure factor of 20 sq m/day. The Stardust Interstellar Preliminary Examination (ISPE) is a consortium-based project to characterize the collection using nondestructive techniques. The goals and restrictions of the ISPE are described . A summary of analytical techniques is described.

Westphal, A. J.↗