Engineering Papers⌕ Search

Engineering topics

Back, H. O.

Publications and source records attributed to Back, H. O..

49 records · Page 3

Results From the First Use of Low Radioactivity Argon in a Dark Matter Search

Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using a two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar39 at a level reduced by a factor (1.4±0.2)×103 relative to atmospheric argon. We report a background-free null result from (2616±43) kg d of data, accumulated over 70.9 live days. When combined with our previous search using an atmospheric argon, the 90% C.L. upper limit on the WIMP-nucleon spin-independent cross section, based on zero events found in the WIMP search regions, is 2.0×10-44 cm2 (8.6×10-44 cm2, 8.0×10-43 cm2) for a WIMP mass of 100 GeV/c2 (1 TeV/c2, 10 TeV/c2).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The veto system of the DarkSide-50 experiment

Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DarkSide Multiton Detector for the Direct Dark Matter Search

A wide range of astronomical evidence implies the existence of Dark Matter, but as yet the nature of this major component of the Universe is completely unknown. A leading candidate explanation is that Dark Matter is composed of Weakly Interacting Massive Particles (WIMPs) formed in the early universe and gravitationally clustered together with the standard baryonic matter. Such WIMPs could in principle be detected through their collisions with ordinary nuclei in a sensitive target, producing observable low-energy (<100 keV) nuclear recoils. The predicted collision rates are very low and require ultra-low background detectors with large (0.1 { 10 tons) target masses, located in deep underground sites to reduce the background produced by neutrons from cosmic ray muons [1{4].

Dark Matter↗

DarkSide search for dark matter

The DarkSide staged program utilizes a two-phase time projection chamber (TPC) with liquid argon as the target material for the scattering of dark matter particles. Efficient background reduction is achieved using low radioactivity underground argon as well as several experimental handles such as pulse shape, ratio of ionization over scintillation signal, 3D event reconstruction, and active neutron and muon vetos. The DarkSide-10 prototype detector has proven high scintillation light yield, which is a particularly important parameter as it sets the energy threshold for the pulse shape discrimination technique. The DarkSide-50 detector system, currently in commissioning phase at the Gran Sasso Underground Laboratory, will reach a sensitivity to dark matter spin-independent scattering cross section of 10 -45 cm 2 within 3 years of operation.

79 ASTRONOMY AND ASTROPHYSICS↗

Light yield in DarkSide-10: A prototype two-phase argon TPC for dark matter searches

As part of the DarkSide program of direct dark matter searches using liquid argon TPCs, a prototype detector with an active volume containing 10 kg of liquid argon, DarkSide-10, was built and operated underground in the Gran Sasso National Laboratory in Italy. A critically important parameter for such devices is the scintillation light yield, as photon statistics limits the rejection of electron-recoil backgrounds by pulse shape discrimination. We have measured the light yield of DarkSide-10 using the readily-identifiable full-absorption peaks from gamma ray sources combined with single-photoelectron calibrations using low-occupancy laser pulses. For gamma lines of energies in the range 122-1275 keV, we get consistent light yields averaging 8.887+-0.003(stat)+-0.444(sys) p.e./keVee. With additional purification, the light yield measured at 511 keV increased to 9.142+-0.006(stat) p.e./keVee.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of the Los Alamos National Laboratory spallation-driven solid-deuterium ultra-cold neutron source

In this paper, we describe the performance of the Los Alamos spallation-driven solid-deuterium ultra-cold neutron (UCN) source. Measurements of the cold neutron flux, the very low energy neutron production rate, and the UCN rates and density at the exit from the biological shield are presented and compared to Monte Carlo predictions. The cold neutron rates compare well with predictions from the Monte Carlo code MCNPX and the UCN rates agree with our custom UCN Monte Carlo code. The source is shown to perform as modeled. The maximum delivered UCN density at the exit from the biological shield is 52(9) UCN/cc with a solid deuterium volume of {approx}1500 cm{sup 3}.

43 PARTICLE ACCELERATORS↗

Purification of Argon from a Diluted Stream

We report on the design, performance and commissioning of a cryogenic distillation column for low radioactivity underground argon purification that has been constructed at Fermi National Accelerator Laboratory. The plant accepts a mixture of argon, helium, and nitrogen with low argon concentration and is designed to return pure argon with a nitrogen contamination less than 10 ppm. During the commissioning, the distillation column in a continuous mode produced argon 99.9% pure. After running in batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The argon production rate was about 1 kg/day.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Commissioning of a Cryogenic Distillation Column for Low Radioactivity Underground Argon

We report on the performance and commissioning of a cryogenic distillation column for low radioactivity underground argon at Fermi National Accelerator Laboratory. The distillation column is designed to accept a mixture of argon, helium, and nitrogen and return pure argon with a nitrogen contamination less than 10 ppm. In the first commissioning, we were able to run the distillation column in a continuous mode and produce argon that is 99.9% pure. After running in a batch mode, the argon purity was increased to 99.95%, with 500 ppm of nitrogen remaining. The efficiency of collecting the argon from the gas mixture was between 70% and 81%, at an argon production rate of 0.84-0.98 kg/day.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astroparticle physics with a customized low-background broad energy Germanium detector

The Majorana Collaboration is building the Majorana Demonstrator, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The Majorana Demonstrator will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c² mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the Majorana Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

dark matter↗

Depleted Argon from Underground Sources

Argon is a strong scintillator and an ideal target for Dark Matter detection; however {sup 39}Ar contamination in atmospheric argon from cosmic ray interactions limits the size of liquid argon dark matter detectors due to pile-up. Argon from deep underground is depleted in {sup 39}Ar due to the cosmic ray shielding of the earth. In Cortez, Colorado, a CO{sub 2} well has been discovered to contain approximately 600 ppm of argon as a contamination in the CO{sub 2}. We first concentrate the argon locally to 3% in an Ar, N{sub 2}, and He mixture, from the CO{sub 2} through chromatographic gas separation, and then the N{sub 2} and He will be removed by continuous distillation to purify the argon. We have collected 26 kg of argon from the CO{sub 2} facility and a cryogenic distillation column is under construction at Fermilab to further purify the argon.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗