Engineering Papers⌕ Search

Engineering topics

B E Lewandowski

Publications and source records attributed to B E Lewandowski.

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Credibility Assessment and Evaluation of the Astronaut Musculoskeletal Boot/Ankle Injury Scenario Using Open SIM(TM) Computational Modeling

The musculoskeletal system of astronauts is subject to physiological changes, potentially leading to injuries due to the exposure to different gravitational environments experienced during spaceflight. These injuries can occur while an astronaut is performing an extravehicular activity (EVA) in space, on lunar or planetary surfaces or while wearing a spacesuit during terrestrial training for an EVA. One area of concern are injuries occurring at the feet and ankles due to a poor fit of the spacesuit boot. These injuries can occur if the boot does not support the ankle sufficiently and the astronaut steps awkwardly, twisting the ankle or foot, during an EVA. The OpenSimTM software can assess EVA induced musculoskeletal injuries for muscle strains, ligament injuries and joint injuries. A modeling and simulation credibility assessment of the OpenSim musculoskeletal modeling and simulation procedures, applied to the boot/ankle injury scenario injury mechanisms that may occur while carrying out tasks in these environments, is performed. These modeling and simulation credibility assessments give information on the credibility of the model’s use in simulating foot/ankle related injury mechanisms.

C A Gallo↗

Modeling and Simulation Credibility Assessment of Finite Element Models for Fall From Heights Injury Scenarios

Finite element (FE) computational models of the whole human body are being used to investigate the injury modalities and mechanisms arising from suited astronauts’ ExtraVehicular Activities (EVAs). These FE whole body models – simplified Elemance and THUMS pedestrian versions – have undergone a series of verification and validation (V&V) assessments for applications in automotive, domestic, and contact sports arenas. However, the FE models’ Modeling and Simulation (M&S) credibility assessments for simulating suited astronaut injuries due to fall from heights in altered gravity environments are limited. The current study evaluates the M&S credibility of simplified Elemance and THUMS pedestrian FE models based on eight credibility factors – data pedigree, input pedigree, code verification, solution verification, conceptual validation, referent validation, results uncertainty, and results robustness – as per NASA-STD-7009A [1]. These credibility factors were assigned ordinal scores ranging between 0 to 4, with a score of 0 in the case of insufficient evidence and 4 when all data for the model is known, used appropriately, and traceable to the Real-World System (RWS) with acceptable accuracy, precision, and uncertainty. The credibility factor sufficiency thresholds were assigned upon guidance from NASA EVA subject matter experts. The factor scores were ascertained through the evaluation of M&S credibility assessment procedures described in the published literature and FE model reports. The M&S credibility scores for the Elemance and THUMS FE models vary between 1 and 3 for data pedigree, input pedigree, and referent validation credibility factors, and between 0 and 1 for code verification, solution verification, conceptual validation, results uncertainty and results robustness. The results show that these FE models are credible for simulating fall from heights injury scenarios in specific kinematic and kinetic ranges that correlate with highway and contact sports-related external conditions. Multiple credibility elevation strategies are prescribed to improve the Elemance and THUMS models’ credibility for use in the EVA fall from height injury scenarios.

R A Perkins↗

Custom Integration of Multiple Medical Functionalities

INTRODUCTION: Previous spaceflight experience and results from probabilistic risk assessment of spaceflight medical risk have highlighted the need for vital sign measurements, medical scopes, and clinical imaging tools for managing medical conditions during spaceflight. The Human Research Program’s Exploration Medical Capability (ExMC) Element and the Mars Campaign Office’s Exploration Medical Integrated Product Team (XMIPT) have performed ground-based evaluations of two Commercial-off-the-Shelf (COTS) Multi-functional Integrated Medical (MIM) devices, which integrate various medical capabilities together in one device. The key findings from these evaluations are presented in a complementary presentation, leaving this presentation to focus on forward recommendations for customized integration of multiple medical functionalities. KEY COMPONENTS: The key features of a custom integration of multiple medical functionalities includes devices and capabilities that optimally reduce medical risk. The COTS MIM devices incorporated functionality for best supporting Earth-based, emergency, pre-hospital care. Our custom integration will use probabilistic risk assessment tools, such as the Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT), to determine the optimal functionality to include based on medical risk minimization. An additional feature of custom integration includes the ability to adapt to different requirements within different vehicles and/or missions. The COTS MIM devices store data in patient specific records, however, the format of the records is not modifiable, and data are not easily transferred from the MIM device to a central data architecture outside of the manufacturer’s established system. Our concept for custom integration will use devices that have an open application programming interface, which can easily connect to independent data architectures and third-party visualization software. The ultrasound capabilities included within the COTS MIM devices did not satisfy many of the Artemis Research and Operations Working Group’s ultrasound functional needs, and therefore, incorporation of higher quality ultrasound capabilities within a customized integration will be beneficial. The COTS MIM devices included minimal procedural guidance and clinical decision support tools. Supplemental tools of this type would need to be supplied along with the COTS MIM devices if they were to be used operationally, so another advantage of customization is the ability to integrate these support tools along with the medical functionality, for a more streamlined user experience. CONCLUSION: Investigation of a customized integration of medical functionality provides a method for further understanding the needs of a long-term exploration spaceflight medical system. The crew members of these exploration missions will need to operate more and more independently from Earth-based ground support. Therefore, having an optimized, streamlined medical system, which contains the functionality and supporting information needed, while remaining within mission and vehicle constraints, will help to maintain crew health and performance, which is necessary for achieving high levels of mission success.

B E Lewandowski↗