Engineering Papers⌕ Search

Engineering topics

Austin, R. A.

Publications and source records attributed to Austin, R. A..

24 records · Page 2

Near Simultaneous Spectroscopic and Polarimetric Observations of Be Stars

Near simultaneous optical spectroscopic (on four nights) and linear continuum (B, V, R and I bands) polarimetric (on seven nights) observations of 29 Be stars were carried out during November - December 1993. The program Be stars displayed wavelength dependence of intrinsic polarizations with no frequency dependence of position angles. Measured values of linear intrinsic polarizations of these Be stars were all less than 1.6%. The Be and Be-shell stars displayed no clear distinction in their polarization values. Observed polarizations at B, V, R and I bands were compared with the theoretically computed linear polarization values of the program stars. It has been suggested that these observed polarizations indicate that the envelopes of the Be stars may have a range of oblateness. Early-type Be stars displayed relatively higher polarizations than the late-type ones. Full widths at half intensity maximum of H(sub alpha) profiles and the intrinsic linear continuum polarizations are closely correlated with the projected rotational velocities of the program stars. Photospheric-absorption-corrected equivalent widths of H(sub alpha), profiles [W((alpha)] and the radii of H(sub alpha) emitting envelopes (R(sub e)) are non-linearly correlated with the intrinsic continuum polarizations of these stars. However, W((alpha) and R(sub e) are linearly correlated. Detail discussion of these results are presented in this paper.

Ghosh, K. K.↗

Uses of continuum radiation in the AXAF calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Uses of Continuum Radiation in the AXAF Calibration

X-ray calibration of the Advanced X-ray Astrophysics Facility (AXAF) observatory at the MSFC X-Ray Calibration Facility (XRCF) made novel use of the x-ray continuum from a conventional electron-impact source. Taking advantage of the good spectral resolution of solid-state detectors, continuum measurements proved advantageous in calibrating the effective area of AXAF's High-Resolution Mirror Assembly (HRMA) and in verifying its alignment to the XRCF's optical axis.

Kolodziejczak, J. J.↗

Development of a Hybrid Gas Detector/Phoswich for Hard X-Ray Astronomy

A hybrid detector is under development for use as a balloon-borne instrument in hard x-ray astronomy. The detector provides broad band coverage by coupling an optical avalanche chamber to a phoswich. The optical avalanche chamber yields superior instrument response at low energies while the scintillator takes over at the higher energies where the gas becomes transparent: at 25 keV, the addition of the gas chamber improves the energy resolution by a factor of 2.5 and the spatial resolution by a factor of 10 as compared to the stand-alone response of the phoswich. A half-scale prototype instrument is being constructed for test purposes and to help resolve a number of design questions involving the coupling of the two components.

Pimperl, M. M.↗

A Hybrid Gas Detector/Phoswich for Hard X-ray Astronomy

A hybrid detector, which combines an optical avalanche chamber with a phoswich, is currently under development. The optical avalanche chamber - a proportional counter designed to give large quantities of light photons during charge multiplication, mounts on the front of the scintillator and gives response at low energies, while the solid scintillator takes over at energies where the gas becomes transparent (greater than 90 keV). Both sections of the hybrid will be read out by a common set of photomultipliers under the phoswich. The addition of the gas section to the phoswich improves the energy resolution of the instrument by a factor of 2.5 at 25 keV and the spatial resolution by a factor of 10 at the same energy. The net result is an instrument with broad band coverage and high sensitivity which will be used for coded aperture imaging on long duration balloon flights.

Ramsey, B. D.↗