Engineering Papers⌕ Search

Engineering topics

Asner, D. M.

Publications and source records attributed to Asner, D. M..

At least 91 records · Page 5

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Measurement of the integrated luminosity of the Phase 2 data of the Belle II experiment

From April to July 2018, a data sample at the peak energy of the Υ(4S) resonance was collected with the Belle II detector at the SuperKEKB electron-positron collider. This is the first data sample of the Belle II experiment. Using Bhabha and digamma events, we measure the integrated luminosity of the data sample to be (496.3±0.3±3.0)pb –1 , where the first uncertainty is statistical and the second is systematic. This work provides a basis for future luminosity measurements at Belle II.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Azimuthal asymmetries of back-to-back π ± - ( π 0 , η , π ± ) pairs in e + e - annihilation

This work reports the first observation of azimuthal asymmetries around the thrust axis in e + e – annihilation of pairs of back-to-back charged pions in one hemisphere, and π 0 and η mesons in the opposite hemisphere. These results are complemented by a new analysis of pairs of back-to-back charged pions. The π 0 and η asymmetries rise with the relative momentum z of the detected hadrons as well as with the transverse momentum with respect to the thrust axis. These asymmetries are sensitive to the Collins fragmentation function $H$ $^{1}_{⊥}$ and provide complementary information to previous measurements with charged pions and kaons in the final state. In particular, the η final states will provide additional information on the flavor structure of $H$ $^{1}_{⊥}$. This is the first measurement of the explicit transverse-momentum dependence of the Collins fragmentation function from Belle data. It uses a dataset of 980.4 fb –1 collected by the Belle experiment at or near a center- of-mass energy of 10.58 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from weakly interacting massive particle (WIMP) dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C3F8 scale in accordance with a new nucleation mechanism, rather than one driven by a hot spike as previously supposed. Using this semiempirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c-2 and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c-2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of a new structure near 10.75 GeV in the energy dependence of the e + e – → Υ(nS)π + π – (n = 1, 2, 3) cross sections

We report a new measurement of the e + e – → Υ(nS)π + π – (n = 1, 2, 3) cross sections at energies from 10.52 to 11.02 GeV using data collected with the Belle detector at the KEKB asymmetric-energy e + e – collider. We observe a new structure in the energy dependence of the cross sections; if described by a Breit-Wigner function its mass and width are found to be M = (10752.7 ± 5.9$^{+0.7}_{–1.1}$) MeV/c 2 and Γ = (35.5$^{+17.6+3.9}_{–11.3–3.3}$) MeV, where the first error is statistical and the second is systematic. The global significance of the new structure including systematic uncertainty is 5.2 standard deviations. We also find evidence for the e + e – → Υ(1S)π + π – process at the energy 10.52 GeV, which is below the $B\overline{B}$ threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First measurement of the CKM angle Φ 3 with $B^±→ D({K}_{\mathrm{S}}^0π^+π^–π^0)K^±$ decays

We present the first model-independent measurement of the CKM unitarity triangle angle Φ 3 using B ± → D ( \( {K}_{\mathrm{S}}^0 \) π + π – π 0 ) K ± decays, where D indicates either a D 0 or \( \overline{D} \) 0 meson. Measurements of the strong-phase difference of the D → \( {K}_{\mathrm{S}}^0 \) π + π – π 0 amplitude obtained from CLEO-c data are used as input. This analysis is based on the full Belle data set of $772 × 10^6 B$ \( \overline{B} \) events collected at the Υ(4 S ) resonance. We obtain Φ 3 = ( \( {5.7}_{-8.8}^{+10.2} \) ± 3 . 5 ± 5 . 7) ° and the suppressed amplitude ratio r B = 0 . 323 ± 0 . 147 ± 0 . 023 ± 0 . 051. Here the first uncertainty is statistical, the second is the experimental systematic, and the third is due to the precision of the strong-phase parameters measured from CLEO-c data. The 95% confidence interval on Φ 3 is ( – 29 . 7 , 109 . 5) ° , which is consistent with the current world average.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of τ – → π – ν τ e + e – and search for τ – → π – ν τ μ + μ –

We present the first measurements of branching fractions of rare tau-lepton decays, τ – → π – ν τ ℓ + ℓ – (ℓ = e or μ), using a data sample corresponding to 562 fb –1 collected at a center-of-mass energy of 10.58 GeV with the Belle detector at the KEKB asymmetric-energy e + e – collider. The τ – → π – ν τ e + e – decay is observed for the first time with 7.0σ significance. The partial branching fraction determined by the structure-dependent mechanisms mediated by either a vector or an axial-vector current for the mass region M πee > 1.05 GeV/c 2 is measured to be B(τ – → π – ν τ e + e – )[M π – e + e – > 1.05 GeV/c 2 ] = (5.90 ± 0.53 ± 0.85 ± 0.11) × 10 –6 , where the first uncertainty is statistical, the second is systematic, and the third is due to model dependence. In the full phase space, due to the different detection efficiencies for the structure-dependent mechanisms mediated by axial-vector and vector currents, the branching fraction varies from B A (τ – → π – ν τ e + e – ) = (1.46 ± 0.13 ± 0.21) × 10 –5 to B V (τ – → π – ν τ e + e – ) = (3.01 ± 0.27 ± 0.43) × 10 –5 , respectively. An upper limit is set on the branching fraction of the τ – → π – ν τ μ + μ – decay, B(τ – → π – ν τ μ + μ – ) < 1.14 × 10 –5 , at the 90% confidence level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

Final results are reported from operation of the PICO-60 C3F8 dark matter detector, a bubble chamber filled with 52 kg of C3F8 located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the weakly interacting massive particle (WIMP)-proton spin-dependent cross section at 3.2×10-41 cm2 for a 25 GeV WIMP, improving on previous PICO results for 3–5 GeV WIMPs by an order of magnitude.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗