Engineering PapersSearch

Engineering topics

Armstrong, T. W.

Publications and source records attributed to Armstrong, T. W..

At least 37 records · Page 2

Status of LDEF radiation modeling

The current status of model prediction and comparison with LDEF radiation dosimetry measurements is summarized with emphasis on major results obtained in evaluating the uncertainties of present radiation environment model. The consistency of results and conclusions obtained from model comparison with different sets of LDEF radiation data (dose, activation, fluence, LET spectra) is discussed. Examples where LDEF radiation data and modeling results can be utilized to provide improved radiation assessments for planned LEO missions (e.g., Space Station) are given.

Watts, John W.

Comparison of model predictions with LDEF satellite radiation measurements

Some early results are summarized from a program under way to utilize Long Duration Exposure Facility (LDEF) satellite data for evaluating and improving current models of the space radiation environment in low Earth orbit. Reported here are predictions and comparisons with some of the LDEF dose and induced radioactivity data, which are used to check the accuracy of current models describing the magnitude and directionality of the trapped proton environment. Preliminary findings are that the environment models underestimate both dose and activation from trapped protons by a factor of about two, and the observed anisotropy is higher than predicted.

Armstrong, T. W.

LDEF satellite radiation study

Some early results are summarized from a program under way to utilize LDEF satellite data for evaluating and improving current models of the space radiation environment in low earth orbit. Reported here are predictions and comparisons with some of the LDEF dose and induced radioactivity data, which are used to check the accuracy of current models describing the magnitude and directionality of the trapped proton environment. Preliminary findings are that the environment models underestimate both dose and activation from trapped protons by a factor of about two, and the observed anisotropy is higher than predicted.

Armstrong, T. W.

Mitigation of adverse environmental effects on lunar-based astronomical instruments

The galactic cosmic-ray flux incident on the Moon was examined for its potential adverse impact on the performance of the large lunar telescope (LLT) proposed as a part of NASA's Space Exploration Initiative (SEI). Noise produced by the cosmic-ray flux in the charge coupled devices (CCD's) to be used as the primary photodetector in the telescope was estimated. It was calculated that approximately 2.5 m of regolith would provide the shielding necessary to reduce the noise to an acceptable level. Dust is an omnipresent environmental concern for any human-assisted or robotic scientific instruments deployed on the Moon. The degree to which dust poses an operational risk to the telescope was examined. Three potential methods for reducing this risk were identified: locating scientific instruments at remote locations; utilizing a prepared, dust-free site for all rocket activities; and covering the optics during high-risk times.

Johnson, Les

Revised prediction of LDEF exposure to trapped protons

The Long Duration Exposure Facility (LDEF) spacecraft flew in a 28.5 deg inclination circular orbit with an altitude in the range from 319.4 to 478.7 km. For this orbital altitude and inclination, two components contribute most of the penetrating charge particle radiation encountered - the galactic cosmic rays and the geomagnetically trapped Van Allen protons. Where shielding is less than 1.0 g/sq cm geomagnetically trapped electrons make a significant contribution. The 'Vette' models together with the associated magnetic field models and the solar conditions were used to obtain the trapped electron and proton omnidirectional fluences reported previously. Results for directional proton spectra using the MSFC anisotropy model for solar minimum and 463 km altitude (representative for the LDEF mission) were also reported. The directional trapped proton flux as a function of mission time is presented considering altitude and solar activity variation during the mission. These additional results represent an extension of previous calculations to provide a more definitive description of the LDEF trapped proton exposure.

Watts, John W.

Absorbed dose measurements and predictions on LDEF

The overall radiation environment of the Long Duration Exposure Facility (LDEF) was determined in part through the use of thermoluminescent detectors (TLD's) which were included in several experiments. The results given are from four experiments (A0015 Biostack, M0004 Fiber Optics Data Link, P0004 Seeds in Space, and P0006 Linear Energy Transfer Spectrum Measurement) and represent a large fraction of existing absorbed dose data. The TLD's were located on the leading and the trailing edges and the Earth end of the spacecraft under various shielding depths (0.48 to 15.4 g/sq cm). The measured absorbed doses were found to reflect both directional dependence of incident trapped protons and shielding. At the leading edge, doses ranged from 2.10 to 2.58 Gy under shielding of 2.90 to 1.37 g/sq cm Al equivalent (M0004). At the trailing edge, doses varied from 3.04 to 4.49 Gy under shielding of 11.7 to 3.85 g/sq cm (A0015), doses varied from 2.91 to 6.64 Gy under shielding of 11.1 to 0.48 g/sq cm (P0004), and a dose range of 2.66 to 6.48 Gy was measured under shielding of 15.4 to 0.48 g/sq cm (P0006). At the Earth end of the spacecraft, doses from 2.41 to 3.93 Gy were found under shielding of 10.0 to 1.66 g/sq cm (A0015). The effect of the trapped proton anisotropy was such that the western side of LDEF received more than 2 times the dose of the eastern side at shielding depths of approximately 1 g/sq cm. Calculations utilizing a directional model of trapped proton spectra predict smaller doses than those measured, being about 50 percent of measured values at the trailing edge and Earth end, and about 80 percent near the leading edge.

Frank, A. L.

Three-dimensional shielding effects on charged particle fluences measured in the P0006 experiment of LDEF

Three-dimensional shielding effects on cosmic ray charged particle fluences were measured with plastic nuclear track detectors in the P0006 experiment on Long Duration Exposure Facility (LDEF). The azimuthal and polar angle distributions of the galactic cosmic ray particles (mostly relativistic iron) were measured in the main stack and in four side stacks of the P0006 experiment, located on the west end of the LDEF satellite. A shadowing effect of the shielding of the LDEF satellite is found. Total fluence of stopping protons was measured as a function of the position in the main and side stacks of the P0006 experiment. Location dependence of total track density is explained by the three-dimensional shielding model of the P0006 stack. These results can be used to validate 3D mass model and transport code calculations and also for predictions of the outer radiation environment for the Space Station Freedom.

Csige, I.

Radiation model predictions and validation using LDEF satellite data

Predictions and comparisons with the radiation dose measurements on Long Duration Exposure Facility (LDEF) by thermoluminescent dosimeters were made to evaluate the accuracy of models currently used in defining the ionizing radiation environment for low Earth orbit missions. The calculations include a detailed simulation of the radiation exposure (altitude and solar cycle variations, directional dependence) and shielding effects (three-dimensional LDEF geometry model) so that differences in the predicted and observed doses can be attributed to environment model uncertainties. The LDEF dose data are utilized to assess the accuracy of models describing the trapped proton flux, the trapped proton directionality, and the trapped electron flux.

Armstrong, T. W.

Future directions for LDEF ionizing radiation modeling and assessments

A calculational program utilizing data from radiation dosimetry measurements aboard the Long Duration Exposure Facility (LDEF) satellite to reduce the uncertainties in current models defining the ionizing radiation environment is in progress. Most of the effort to date has been on using LDEF radiation dose measurements to evaluate models defining the geomagnetically trapped radiation, which has provided results applicable to radiation design assessments being performed for Space Station Freedom. Plans for future data comparisons, model evaluations, and assessments using additional LDEF data sets (LET spectra, induced radioactivity, and particle spectra) are discussed.

Armstrong, T. W.

Revised predictions of LDEF exposure to trapped protons

Initial estimates of LDEF exposure to the trapped proton environment were reported previously to aid in the interpretation dosimetry data and in conjunction with dosimetry response predictions. These previous estimates were made using the standard NASA AP8 trapped proton models for two sets of assumed conditions: (1) the omnidirectional flux spectra were calculated with the LDEF altitude and solar activity variations taken into account; and (2) the NASA Marshall anisotropy model was applied to obtain directional spectra, but only for solar minimum conditions and at a single altitude. Herein, the directional trapped proton fluence spectra is calculated considering both the altitude variation and solar activity during the LDEF mission. These additional results represent an extension of previous calculations to provide a more definitive description of the LDEF trapped proton exposure.

Watts, J. W., Jr.

Absorbed dose measurements and predictions on LDEF

The overall radiation environment of LDEF was determined in part through the use of thermoluminescent detectors (TLDs). The results given are from four experiments (Biostack, Fiber Optics Data Link, Seeds in Space, and Linear Energy Transfer Spectrum Measurement) and represent a large fraction of existing absorbed dose data. The TLDs (located on leading and trailing edges) were under various shielding depths. The measured absorbed doses were found to reflect both directional dependence of incident trapped protons and shielding. Radiation dosages at both locations and under various shielding depths are given. The effect of the trapped proton anisotropy was such that the western side of LDEF received about 3 times the dose of the eastern side at shielding depths of approx. 1 gm/sq cm. These data are being used to evaluate the accuracy of models currently in use for predicting ionizing radiation environments for low Earth orbit missions.

Frank, A. L.

Three-dimensional shielding effects on charged particle fluences measured in the P0006 experiment in LDEF

The azimuthal and polar angle distribution of the galactic cosmic ray particles (mostly relativistic iron) was measured in the main stack and four side stacks of the P0006 experiment located on the west end of the LDEF satellite. A clear shadowing effect of the radiation shielding of the LDEF satellite is found. The total fluence of stopping protons (mostly primary, trapped particles) was measured as a function of the position in the main and side stacks of the P0006 experiment. Experimental results are compared with theoretical calculations and the effect of the strong location dependence of particle fluences is explained by the three dimensional shielding model of the P0006 stack. Through comparisons between experimental results and calculations, this work will lead to the refinement of the radiation environment computational models.

Csige, I.

Development and application of a 3-D geometry/mass model for LDEF satellite ionizing radiation assessments

A computer model of the three dimensional geometry and material distributions for the LDEF spacecraft, experiment trays, and, for selected trays, the components of experiments within a tray was developed for use in ionizing radiation assessments. The model is being applied to provide 3-D shielding distributions around radiation dosimeters to aid in data interpretation, particularly in assessing the directional properties of the radiation exposure. Also, the model has been interfaced with radiation transport codes for 3-D dosimetry response predictions and for calculations related to determining the accuracy of trapped proton and cosmic ray environment models. The methodology is described used in developing the 3-D LDEF model and the level of detail incorporated. Currently, the trays modeled in detail are F2, F8, and H12 and H3. Applications of the model which are discussed include the 3-D shielding distributions around various dosimeters, the influence of shielding on dosimetry responses, and comparisons of dose predictions based on the present 3-D model vs those from 1-D geometry model approximations used in initial estimates.

Colborn, B. L.

Radiation model predictions and validation using LDEF data

Radiation dosimetry aboard LDEF, as well as post-flight measurements of the radioactivity induced in numerous LDEF spacecraft components, provide unique data for evaluating the accuracy of current models for predicting both the space radiation environments (trapped proton intensity, spectra, and directionality; cosmic ray fluence) and the radiation environments induced in spacecraft components (fluence, energy spectra, secondary particle, linear energy transfer, etc.). By determining the accuracy of such models using LDEF data, and with model updates where required, improved radiation environment predictions can be made for future missions, which in turn allows improved predictions for specific radiation effects for future spacecraft components (single event upsets of microelectronics, radiation damage to focal plane arrays, noise in sensitive instrumentation, etc.). Herein, the status and results from radiation model predictions and comparisons with LDEF data is given. The calculations are made using radiation transport codes coupled with a 3-D geometry/mass model of LDEF, together with current models of the space radiation environment.

Armstrong, T. W.

Future directions for LDEF ionizing radiation modeling and assessments

Data from the ionizing radiation dosimetry aboard LDEF provide a unique opportunity for assessing the accuracy of current space radiation models and in identifying needed improvements for future mission applications. Details are given of the LDEF data available for radiation model evaluations. The status is given of model comparisons with LDEF data, along with future directions of planned modeling efforts and data comparison assessments. The methodology is outlined which is related to modeling being used to help insure that the LDEF ionizing radiation results can be used to address ionizing radiation issues for future missions. In general, the LDEF radiation modeling has emphasized quick-look predictions using simplified methods to make comparisons with absorbed dose measurements and induced radioactivity measurements of emissions. Modeling and LDEF data comparisons related to linear energy transfer spectra are of importance for several reasons which are outlined. The planned modeling and LDEF data comparisons for LET spectra is discussed, including components of the LET spectra due to different environment sources, contribution from different production mechanisms, and spectra in plastic detectors vs silicon.

Armstrong, T. W.

Geometry and mass model of ionizing radiation experiments on the LDEF satellite

Extensive measurements related to ionizing radiation environments and effects were made on the LDEF satellite during its mission lifetime of almost 6 years. These data, together with the opportunity they provide for evaluating predictive models and analysis methods, should allow more accurate assessments of the space radiation environment and related effects for future missions in low Earth orbit. The LDEF radiation dosimetry data is influenced to varying degrees by material shielding effects due to the dosimeter itself, nearby components and experiments, and the spacecraft structure. A geometry and mass model is generated of LDEF, incorporating sufficient detail that it can be applied in determining the influence of material shielding on ionizing radiation measurements and predictions. This model can be used as an aid in data interpretation by unfolding shielding effects from the LDEF radiation dosimeter responses. Use of the LDEF geometry/mass model, in conjunction with predictions and comparisons with LDEF dosimetry data currently underway, will also allow more definitive evaluations of current radiation models for future mission applications.

Colborn, B. L.

Prediction of LDEF ionizing radiation environment

The Long Duration Exposure Facility (LDEF) spacecraft flew in a 28.5 deg inclination circular orbit with an altitude in the range from 172 to 258.5 nautical miles. For this orbital altitude and inclination two components contribute most of the penetrating charge particle radiation encountered - the galactic cosmic rays and the geomagnetically trapped Van Allen protons. Where shielding is less than 1.0 g/sq cm geomagnetically trapped electrons make a significant contribution. The 'Vette' models together with the associated magnetic filed models were used to obtain the trapped electron and proton fluences. The mission proton doses were obtained from the fluence using the Burrell proton dose program. For the electron and bremsstrahlung dose we used the Marshall Space Flight Center (MSFC) electron dose program. The predicted doses were in general agreement with those measured with on-board thermoluminescent detector (TLD) dosimeters. The NRL package of programs, Cosmic Ray Effects on MicroElectronics (CREME), was used to calculate the linear energy transfer (LET) spectrum due to galactic cosmic rays (GCR) and trapped protons for comparison with LDEF measurements.

Watts, John W.

Ionizing radiation calculations and comparisons with LDEF data

In conjunction with the analysis of LDEF ionizing radiation dosimetry data, a calculational program is in progress to aid in data interpretation and to assess the accuracy of current radiation models for future mission applications. To estimate the ionizing radiation environment at the LDEF dosimeter locations, scoping calculations for a simplified (one dimensional) LDEF mass model were made of the primary and secondary radiations produced as a function of shielding thickness due to trapped proton, galactic proton, and atmospheric (neutron and proton cosmic ray albedo) exposures. Preliminary comparisons of predictions with LDEF induced radioactivity and dose measurements were made to test a recently developed model of trapped proton anisotropy.

Armstrong, T. W.