Engineering PapersSearch

Engineering topics

Antonio J. Ricco

Publications and source records attributed to Antonio J. Ricco.

Electronic Nose Development and Preliminary Human Breath Testing for Rapid, Non-Invasive COVID-19 Detection

We adapted an existing, spaceflight-proven, robust “electronic nose” (E-Nose) that uses an array of electrical resistivity-based nanosensors mimicking aspects of mammalian olfaction to conduct on-site, rapid screening for COVID-19 infection by measuring the pattern of sensor responses to volatile organic compounds (VOCs) in exhaled human breath. We built and tested multiple copies of a hand-held prototype E-Nose sensor system, composed of 64 chemically sensitive nanomaterial sensing elements tailored to COVID-19 VOC detection; data acquisition electronics; a smart tablet with software (App) for sensor control, data acquisition and display; and a sampling fixture to capture exhaled breath samples and deliver them to the sensor array inside the E-Nose. The sensing elements detect the combination of VOCs typical in breath at parts-per-billion (ppb) levels, with repeatability of 0.02% and reproducibility of 1.2%; the measurement electronics in the E-Nose provide measurement accuracy and signal-to-noise ratios comparable to benchtop instrumentation. Preliminary clinical testing at Stanford Medicine with 63 participants, their COVID-19-positive or COVID-19-negative status determined by concomitant RT-PCR, discriminated between these two categories of human breath with a 79% correct identification rate using “leave-one-out” training-and-analysis methods. Analyzing the E-Nose response in conjunction with body temperature and other non-invasive symptom screening using advanced machine learning methods, with a much larger database of responses from a wider swath of the population, is expected to provide more accurate on-the-spot answers. Additional clinical testing, design refinement, and a mass manufacturing approach are the main steps toward deploying this technology to rapidly screen for active infection in clinics and hospitals, public and commercial venues, or at home.

COVID-19

Europan Molecular Indicators of Life Investigation (EMILI) for a Future Europa Lander Mission

The Europan Molecular Indicators of Life Investigation (EMILI) is an instrument concept being developed for the Europa Lander mission currently under study. EMILI will meet and exceed the scientific and technical/resource requirements of the organic composition analyzer identified as a core instrument on the Lander. EMILI tightly couples two complementary analytical techniques, based on 1) liquid extraction and processing with capillary electrophoresis and 2) thermal and chemical extraction with gas chromatography, to robustly detect, structurally characterize, and quantify the broadest range of organics and other Europan chemicals over widely-varying concentrations. Dual processing and analysis paths enable EMILI to perform a thorough characterization of potential molecular biosignatures and contextual compounds in collected surface samples. Here we present a summary of the requirements, design, and development status of EMILI with projected scientific opportunities on the Europa Lander as well as on other potential life detection missions seeking potential molecular biosignatures in situ.

Europa

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier

Extraterrestrial Molecular Indicators of Life Investigation (EMILI)

Future missions to Enceladus, Europa, Mars, and beyond may seek the molecular signs of extraterrestrial life through chemical analysis of acquired samples. Particularly on ocean worlds such as Enceladus and Europa, samples may contain trace ocean-borne molecular biosignatures of extant life that may or may not share similarities to those of terrestrial life. In situ analyses must be prepared to detect and characterize a wide range of possible molecular species, structures, and patterns, typically with exquisite sensitivity and within a complex, poorly-characterized planetary environment. The Extraterrestrial Molecular Indicators of Life Investigation (EMILI) is designed to meet or exceed the requirements of such missions for organic molecular analysis through a powerful combination of dual chemical separation and both optical and mass spectrometry detection techniques, realized in an integrated, compact instrument package fully compatible with anticipated flight resources and conditions. The full EMILI instrument combines two sample analysis subsystems to provide wide-ranging and complementary detection of organic compounds and inorganic salts. The Gas Analysis Processing System (GAPS) uses a chemical derivatization protocol with gas chromatography (GC) separation prior to detection in an ion trap mass spectrometer (ITMS) to enable full characterization of lower-polarity, volatile and semi-volatile molecules such as fatty acids and hydrocarbons. The Organic Capillary Electrophoresis ANalysis System (OCEANS) uses a liquid-based extraction protocol with CE separation to enable precise analysis of more water-soluble/polar compounds. OCEANS features a laser-induced fluorescence detection mode to perform ultra-sensitive quantitative analysis of chiral amino acids. In EMILI, OCEANS is additionally coupled to the same ITMS through a novel electrospray ionization interface. The common ITMS allows EMILI to identify and cross-correlate molecular species and patterns, detected through either or both protocols, of molecular weights to over 1000 u, potentially even revealing complex biosignatures such as alien oligopeptides and informational polymers.

Europa