Engineering PapersSearch

Engineering topics

Anselmo, V. J.

Publications and source records attributed to Anselmo, V. J..

Programmable temperature control system for biological materials

A system was constructed which allows programmable temperature-time control for a 5 cu cm sample volume of arbitrary biological material. The system also measures the parameters necessary for the determination of the sample volume specific heat and thermal conductivity as a function of temperature, and provides a detailed measurement of the temperature during phase change and a means of calculating the heat of the phase change. Steady-state and dynamic temperature control is obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container is totally immersed into a cold heat sink. Using a mixture of dry ice and alcohol at 79 C, the sample volume can be controlled from +40 to -60 C at rates from steady state to + or - 65 C/min. Steady-state temperature precision is better than 0.2 C, while the dynamic capability depends on the temperature rate of change as well as the mass of both the sample and the container.

Anselmo, V. J.

Wakeflow analysis by cost

COST (Computerized Optical Scanning Tomography) is proposed for visualizing wakeflows of aircraft and wind-tunnel models. Operating very close to real time, COST hardware could be installed at airports to monitor turbulent flow trailing large aircraft, so that smaller aircraft could be directed to avoid turbulence. Real-time analysis of jet-engine exhaust plumes, to reduce pollution and optimize performance, is also possible.

Anselmo, V. J.

Application of imaging and ultrasound to the quality grading of beef

The results of a study conducted to assist the Department of Agriculture in the task of considering innovative methods for the grading of carcass beef for human consumption is presented. The processing of photographic, television and ultrasound images of the longissimus dorsi muscle at the 12/13th rib cut was undertaken. The results showed that a correlation could be developed between the quality grade of the carcass as determined by a professional grader, and the fat to area ratio of the muscle as determined by image processing techniques. In addition, the use of ultrasound shows the potential for grading of an unsliced carcass or a live animal.

Anselmo, V. J.

Medical diagnosis system and method with multispectral imaging

A skin diagnosis system includes a scanning and optical arrangement whereby light reflected from each incremental area (pixel) of the skin is directed simultaneously to three separate light filters, e.g., IR, red, and green. As a result, the three devices simultaneously produce three signals which are directly related to the reflectance of light of different wavelengths from the corresponding pixel. These three signals for each pixel after processing are used as inputs to one or more output devices to produce a visual color display and/or a hard copy color print, for one usable as a diagnostic aid by a physician.

Anselmo, V. J.

Microcomputer helps evaluate skin burns

Microcomputer analysis of multispectral imaging of burn area aids production of display map of field and partial thickness burns making more effective clinical treatment possible.

Anselmo, V. J.

A controlled rate freeze/thaw system for cryopreservation of biological materials

A system which allows programmable temperature-time control for a 5 cc sample volume of an arbitrary biological material was constructed. Steady state and dynamic temperature control was obtained by supplying heat to the sample volume through resistive elements constructed as an integral part of the sample container. For cooling purposes, this container was totally immersed into a cold heat sink. Sample volume thermodynamic property data were obtained by measurements of heater power and heat flux through the container walls. Using a mixture of dry ice and alcohol at -79 C, sample volume was controlled from +40 C to -60 C at rates from steady state to + or - 65 C/min. Steady state temperature precision was better than 0.2 C while the dynamic capability depends on the temperature rate of change as well as the thermal mass of the sample and the container.

Anselmo, V. J.

Diagnosis of cutaneous thermal burn injuries by multispectral imaging analysis

Special photographic or television image analysis is shown to be a potentially useful technique to assist the physician in the early diagnosis of thermal burn injury. A background on the medical and physiological problems of burns is presented. The proposed methodology for burns diagnosis from both the theoretical and clinical points of view is discussed. The television/computer system constructed to accomplish this analysis is described, and the clinical results are discussed.

Anselmo, V. J.

Body/bone-marrow differential-temperature sensor

Differential-temperature sensor developed to compare bone-marrow and body temperature in leukemia patients uses single stable amplifier to monitor temperature difference recorded by thermocouples. Errors are reduced by referencing temperatures to each other, not to separate calibration points.

Anselmo, V. J.

Effect of evaporative surface cooling on thermographic assessment of burn depth

Differences in surface temperature between evaporating and nonevaporating, partial- and full-thickness burn injuries were studied in 20 male, white guinea pigs. Evaporative cooling can disguise the temperature differential of the partial-thickness injury and lead to a false full-thickness diagnosis. A full-thickness burn with blister intact may retain enough heat to result in a false partial-thickness diagnosis. By the fourth postburn day, formation of a dry eschar may allow a surface temperature measurement without the complication of differential evaporation. For earlier use of thermographic information, evaporation effects must be accounted for or eliminated.

Anselmo, V. J.

Multispectral imaging for medical diagnosis

Photography technique determines amount of morbidity present in tissue. Imaging apparatus incorporates numerical filtering. Overall system operates in near-real time. Information gained from this system enables physician to understand extent of injury and leads to accelerated treatment.

Anselmo, V. J.