A guide on modeling electrostatics of semiconductor detectors in COMSOL Multiphysics ® for DRiFT

Adding a new semiconductor detector into the detector response function toolkit (DRiFT) requires a model of the electric potential and the electric field. To get an accurate electrostatics model, the geometry of the detector should be modeled as closely to the real geometry as feasible, including the semiconductor materials, doping layers and concentrations, and contacts. Since the electric field and potential are used to calculate the induced signal, the results of the detector response functions are largely influenced by the electrostatics models. Initial electrostatics models were completed using Silvaco, however, this document provides guidance on using COMSOL Mulitphysics ® (COMSOL) to model the detectors to give users additional flexibility. Guidance on using COMSOL and its user interface are mostly left out of this document, but best practices for geometry, modeling methods, and data format/exporting are included to help users generate models that are compatible with DRiFT, prevents bugs, issues, and inaccuracies during charge collection calculations. The following summary provides an overview of the document.

42 ENGINEERING↗

DRiFT Current Mode, Trigger Settings and Flexible Detector Specifications Applied to Scintillator Arrays

MCNP radiation transport output is post-processed by DRiFT, a Detector Response Function Toolkit to simulate detailed nuclear instrumentation response. DRiFT can be used to assess the performance and potential limitations of scintillator, gas, and semiconductor detectors under a variety of simulated conditions not easily achievable in a laboratory setting. This work describes new updates in DRiFT for scintillator simulations which focus on the capability to simulate scintillators in current mode, an expansion of trigger options, and the ability to customize individual detector properties in a simulation. These improvements are designed to facilitate the ability to model large arrays of scintillator detectors with higher fidelity than was previously possible and are demonstrated in three examples. The first shows the difference between operating DRiFT in current and pulse mode. In the second example, which is intended to demonstrate deviations in individual detector performance, each detector has properties (PMT gain, optical transport, scintillation yield, etc.) that vary between detectors and are specified in DRiFT. A final example examines how DRiFT could be used to optimize digitizer settings in high rate measurements with split signals using the new common trigger option.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-purity germanium semiconductor modeling in the detector response function toolkit

In this study, we have extended the detector response function toolkit (DRiFT) to provide modeling capabilities of semiconductor sensors. DRiFT provides realistic nuclear instrumentation response by post-processing Monte-Carlo N-particle (MCNP®) radiation transport outputs. MCNP® is capable of modeling radiation transport in complex environments, but has limited detector physics and readout electronics modeling capabilities. Semiconductor detector response can be calculated with a high-fidelity for a flexible range of environments by utilizing MCNP® to simulate radiation interactions inside of detector volumes, and then using DRiFT to model charge transport and signal formation in the semiconductor, as well as the readout electronics. DRiFT models charge transport in the semiconductor, the preamplifier, shaping amplifier, pulse pile-up, and electronic noise to generate detector response. The semiconductor application in DRiFT can model a range of semiconductor materials, shapes, and sizes; and is demonstrated here for a large volume coaxial high-purity germanium (HPGe) detector. Here, we compare detector response functions of a coaxial HPGe detector with measurement of 60 Co, 133 Ba, and 137 Cs at varying count rates, and we conduct a parameter study to demonstrate the effect of changing parameters in the DRiFT simulation. The HPGe detector response function shows excellent agreement with measurements of difference sources with varying dead times and count rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗