Engineering Papers⌕ Search

Engineering topics

Andrews, Heather Lynn

Publications and source records attributed to Andrews, Heather Lynn.

Effect of material composition of diamond field emission array cathodes on quality of transversely shaped beams

Diamond field emitter array field emission cathodes (DFEA FECs) are attractive for the next generation of injectors due to their ability to produce transversely shaped beams without the need for complex masking or laser schemes. However, reliability of this cathode technology remains a challenging issue as principal mechanisms guiding and allowing for output beam shaping remained poorly understood. Here, this paper reports the results of testing two DFEA FECs with the same pattern and emitter tip geometry. Although both cathodes were able to sustain gradients of 44 MV/m and produce maximum output integral charge of 0.5 nC per radio frequency pulse, their emission patterns were different. One cathode did not produce a shaped beam, while the other one did. This difference was explained by the extent of the local variations of the diamond material across the arrays as discovered by spatially resolved Raman spectroscopy. The main practical takeaways were (i) tip sharpness was not a prerequisite for producing a shaped beam and instead (ii) material characteristics resulting in different cathode ballast resistance affected emission spatial uniformity across the array and hence the beam shaping.

36 MATERIALS SCIENCE↗

Shaped Beams from Diamond Field-Emitter Array Cathodes

Diamond field-emitter arrays (DFEAs) are arrays of diamond pyramids with exquisitely sharp tips and micrometer-scale bases that produce high current densities. These arrays can be fabricated in arbitrary shapes, ranging from single tips to many millions of tips, so that they produce an inherently shaped electron beam. Each tip emits a modest current, but the large dense array can produce many Amps. We are investigating these cathodes for use in dielectric wakefield accelerators; however, they may also be applicable to vacuum microwave tubes. Recently, shaped beam production and transport have been demonstrated in the 1.3-GHz RF gun at the Argonne Cathode Test Stand at the Argonne National Laboratory. The charge was measured on a Faraday cup and the beam imaged on a YAG screen with peak electric field gradients on the cathode ranging from 12 to 35 MV/m. Three cathode geometries were tested: one 1-mm equilateral triangle with 7-mu m base pyramids and 10-mu m pitch, one 1-mm equilateral triangle with 10-mu m base and 25-mu m pitch, and one sparse 5 x 5 square array with 20-mu m base and 400-mu m pitch. The two triangular arrays emitted 35 nC in an RF macropulse at 35 MV/m and 13-nC charge at 27 MV/m, respectively, while the sparse array emitted 0.060-nC charge at 15 MV/m. This article presents the results of the triangular array experiments, including damage due to breakdown in the RF gun and initial models of tip-to-tip shielding.

Cathodes↗

Divergence study and emittance measurements for the electron beam emitted from a diamond pyramid

This paper reports the results of a divergence study and emittance measurements for an electron beam emitted from a single diamond pyramid in a sparse diamond field-emitter array (DFEA) cathode. DFEA cathodes are arrays of micrometer scale diamond pyramids with nanometer scale tips. A single diamond pyramid produces currents as high as 10 μA from a small surface area. DFEA cathodes are expected to be a good beam source for compact dielectric laser accelerators. For the electron beam divergence experiment, we have designed and assembled a test stand consisting of a DFEA cathode, a mesh anode, and a screen. We measured current and the size of the beam on the screen as functions of the distance between the cathode and the anode, the size of a pyramid’s base, and applied voltage on the cathode. In order to perform beam emittance measurements, we designed and fabricated a magnetic lens to be placed between the mesh and the screen. By measuring the size of the beam for different distances between the lens and the screen, we estimate the beam’s emittance. Here, we also simulated the electron beam dynamics with Computer Simulation Technology Studio and General Particle Tracer codes. Experimentally measured divergence angles and normalized transverse emittance show good agreement with simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling of diamond field emitter arrays for a compact source of high brightness electron beams

Many applications, such as compact accelerators and electron microscopy, demand high brightness electron beams with small source size and ultralow emittance. Diamond emitters manufactured with semiconductor processes can be employed in such compact beam sources. The micrometer-scale pyramid structure of the emitter allows enhancement of the external field compared to that at the substrate, leading to electron emission with small beam size. We investigate the dependence of the field enhancement on the shape of the emitter and the resulting emission characteristics. The beam formation and dynamics are simulated with the LSP particle-in-cell code to obtain the macroscopic observables. To account for the semiconductor charge transport in the bulk material and the tunneling through the surface, a first-principle semiclassical Monte Carlo emission model is developed and applied to the diamond pyramid. Using this Monte Carlo emission model and the result from the geometric field enhancement calculation, we construct a simple model to qualitatively explain the measured emission characteristics. In conclusion, a comparison between our model and experiments indicates that the beam current is mostly emitted at the apex of the emitter.

36 MATERIALS SCIENCE↗

Hydrodynamic disassembly and expansion of electron-beam-heated warm dense copper

Cu foils, 200 μm in thickness, were heated in two stages by a ~100-ns-long monoenergetic electron bunch at 19.8 MeV and a current of 1.7 kA (8.5 × 10 14 e - ) in a 2-mm-spot to T e ~1 eV. After 45 ns of isochoric heating, the pressure in the foil builds up to >20 GPa (200 kbar), it begins to hydrodynamically disassemble, and a velocity spread is measured. Near the end of the electron pulse, the 1550 nm probe is cut off or absorbed. Photonic Doppler velocimetry measurements were made to quantify the expansion velocity, hydrodynamic disassembly time, and pressure of the foil prior to cutoff. Measurements indicate foil motion begins the instant electrons pass through the foil and continues until the particle velocity approaches the ambient sound velocity of Cu and the bulk density exceeds the critical density of the probe. Finally, once the density of the plasma drops below the critical threshold and begins reflecting again, an expansion velocity of the classical plasma is also measured, similar to the point-source solution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diamond field emitter array cathodes and possibilities for employing additive manufacturing for dielectric laser accelerating structures

These are slides for a presentation at Stanford University. The outline is as follows: Motivation: customers for compact accelerators, LANL's technologies for laser acceleration, DFEA cathodes, and additive manufacturing of micron-size structures. Among the stated conclusions are the following: preliminary study identified DFEA cathodes as promising sources for DLAs--high beam current and small emittance; additive manufacturing with Nanoscribe Professional GT can produce structures with the right scale features for a DLA operating at micron wavelengths (fabrication tolerances need to be studied, DLAs require new materials). Future plans include DLA experiment with a beam produced by the DFEA cathode with field emission, demonstration of photoemission from DFEAs, and new structures to print and test.

43 PARTICLE ACCELERATORS↗

Influence of sweeping detonation-wave loading on damage evolution during spallation loading of tantalum in both a planar and curved geometry

Widespread research over the past five decades has provided a wealth of experimental data and insight concerning the shock hardening, damage evolution, and the spallation response of materials subjected to square-topped shock-wave loading profiles. However, fewer quantitative studies have been conducted on the effect of direct, in-contact, high explosive (HE)-driven Taylor wave (unsupported shocks) loading on the shock hardening, damage evolution, or spallation response of materials. Systematic studies quantifying the effect of sweeping-detonation wave loading are yet sparser. In this study, the damage evolution and spallation response of Ta is shown to be critically dependent on the peak shock stress, the geometry of the sample (flat or curved plate geometry), and the shock obliquity during sweeping-detonation-wave shock loading. Sweepingwave loading in the flat-plate geometry is observed to: a) yield a lower spall strength than previously documented for 1-D supported-shock-wave loading, b) exhibit increased shock hardening as a function of increasing obliquity, and c) lead to an increased incidence of deformation twin formation with increasing shock obliquity. Sweeping-wave loading of a 10 cm radius curved Ta plate is observed to: a) lead to an increase in the shear stress as a function of increasing obliquity, b) display a more developed level of damage evolution, extensive voids and coalescence, and lower spall strength with obliquity in the curved plate than seen in the flat-plate sweeping-detonation wave loading for an equivalent HE loading, and c) no increased propensity for deformation twin formation with increasing obliquity as seen in the flat-plate geometry. The overall observations comparing and contrasting the flat versus curved sweeping-wave spall experiments with 1D loaded spallation behavior suggests a coupled influence of obliquity and geometry on dynamic shock-induced damage evolution and spall strength. Coupled experimental and modeling research to quantify the combined effects of sweeping-wave loading with increasingly complex sample geometries on the shockwave response of materials is clearly crucial to providing the basis for developing and thereafter validation of predictive modeling capability.

36 MATERIALS SCIENCE↗