Interlaboratory Study for Characterizing Monoclonal Antibodies by Top-Down and Middle-Down Mass Spectrometry

The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product’s primary structure reliably and reproducibly. The major objective of the present study was to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up approaches, such as confirming protein integrity, sequencing variable domains, ruling out artefacts, and revealing modifications and their locations. A panel of three mAbs was selected and centrally provided to twenty laboratories worldwide for the analysis: Sigma mAb standard (SiLuLite), NIST mAb standard, and the therapeutic mAb Herceptin (trastuzumab). A variety of different MS instrument platforms and ion dissociation techniques were employed. Overall, the present study confirms that MD/TD MS strategies are valuable and readily available tools in laboratories worldwide. They provide complementary information to the bottom-up approach and can add unique information, which may be crucial for comprehensive mAb characterization. The current limitations, as well as possible solutions to overcome them, are also outlined. One of the limitations revealed by the results of the present study is that the expert knowledge in both experiment and data analysis is indispensable to practice TD/MD MS, but the number of TD/MD MS experts is still very low.

59 BASIC BIOLOGICAL SCIENCES↗

Ion-Ion Proton Transfer and Parallel Ion Parking for the Analysis of Mixtures of Intact Proteins on a Modified Orbitrap Mass Analyzer

We have enabled parallel ion parking on a modified Orbitrap Elite™ as a way to control ion-ion proton transfer reactions via selective activation of a range of ions. The result is the concentration of the majority of ion current from multiple charge states of each precursor proteoform into a single charge state, maximizing signal intensity and increasing effective sensitivity compared to conventional MS1 spectra. These techniques were applied in an on-line HPLC, data-dependent MS/MS analysis of intact E. coli ribosomal proteins with HCD fragmentation. With one injection, all but two ribosomal proteins were selected for fragmentation and subsequently identified. The techniques described facilitate rapid identification of intact proteins in complex mixtures and an enhanced ability to observe proteins of low abundance. .

74 ATOMIC AND MOLECULAR PHYSICS↗

A five-level classification system for proteoform identifications

The term proteoform, introduced in these pages in 2013, has rapidly gained acceptance in the proteomics community. The challenge and importance of comprehensively identifying proteoforms in complex samples has been recognized, and reports have begun to appear of new platforms towards that end. However, one interesting central ambiguity has emerged, namely determining precisely what is meant by a “proteoform identification”. At present, the only practical approaches for establishing the exact primary structure of a proteoform employ mass spectrometry (MS), and there is a wide range of MS results that provide “proteoform identifications”. This seemingly small matter has significant impact, as the ambiguity in knowing what is meant by an “identification” makes it difficult to compare results from different laboratories and approaches. This situation hinders the ability of the community to evaluate technological progress and to efficiently expand biological knowledge. To address this issue, we propose a five-level system for classifying proteoform identifications. Here, the classification scheme stems directly from a consideration of the four types of possible ambiguity possible for a proteoform identification, ranging from the most subtle (i.e., precise localization of a post-translational modification, or PTM) to the most dramatic (i.e., ambiguity in the gene of origin). The five classes then correspond to the level of ambiguity present in the identification, ranging from no ambiguity at all (Level 1), to ambiguity of all four types (Level 5). Details of the scheme are provided in Table 1 and Supplementary Table 1, with specific use cases and examples provided in Supplementary Figure 1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Front-End Electron Transfer Dissociation Coupled to a 21 Tesla FT-ICR Mass Spectrometer for Intact Protein Sequence Analysis

High resolution mass spectrometry is a key technology for in-depth protein characterization. High-field Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) enables high-level interrogation of intact proteins in the most detail to date. However, an appropriate complement of fragmentation technologies must be paired with FTMS to provide comprehensive sequence coverage, as well as characterization of sequence variants, and post-translational modifications. Here we describe the integration of front-end electron transfer dissociation (FETD) with a custom-built 21 tesla FT-ICR mass spectrometer, which yields unprecedented sequence coverage for proteins ranging from 2.8 to 29 kDa, without the need for extensive spectral averaging (e.g., ~60% sequence coverage for apo-myoglobin with four averaged acquisitions). The system is equipped with a multipole storage device separate from the ETD reaction device, which allows accumulation of multiple ETD fragment ion fills. Consequently, an optimally large product ion population is accumulated prior to transfer to the ICR cell for mass analysis, which improves mass spectral signal-to-noise ratio, dynamic range, and scan rate. We find a linear relationship between protein molecular weight and minimum number of ETD reaction fills to achieve optimum sequence coverage, thereby enabling more efficient use of instrument data acquisition time. Finally, real-time scaling of the number of ETD reactions fills during method-based acquisition is shown, and the implications for LC-MS/MS top-down analysis are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗