Engineering Papers⌕ Search

Engineering topics

Alyson D. Topper

Publications and source records attributed to Alyson D. Topper.

Proton Test Report Micropac 66212-300 Optocoupler

The purpose of this test was to determine the displacement damage and total ionizing dose sensitivity of Micropac’s 66212 optocoupler. During the test, the device was exposed to protons. Device parameters such as CTR, reverse current, and forward voltage were investigated.

displacement damage↗

NASA Goddard Space Flight Center’s Compendium of Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FETs, flash memory, FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single Event Effects (SEE)↗

Failure Analysis of Heavy-Ion-Irradiated Schottky Diodes

In this paper, we use high- and low-magnification optical microscope images, thermal infrared camera images, and scanning electron microscope images to identify failure locations in heavy-ion-irradiated Schottky diodes. After failures have been identified, the parts were cross-sectioned to describe the structure of the failures and energy dispersive x-ray spectroscopy was used to characterize the materials in the failure structures.

Radiation effects↗

Schottky Diode Derating for Survivability in a Heavy Ion Environment

In this paper, we irradiate a number of silicon power Schottky diodes from a variety of manufacturers. The tested diodes represent a wide assortment of reverse voltages and forward currents. Additionally, we review correlations between single-event failures in Schottky diodes and device electrical parameters. The spatial locations of failures in the diode are discussed, as well as a possible explanation for why the failures occur. Based on these correlations to date, we propose a derating scheme for Schottky diodes flown in a heavy ion environment and suggest screening procedures for decreasing the risks of such failures.

Radiation effects↗

Space Radiation Effects on SiC Power Device Reliability

Heavy-ion radiation can result in silicon carbide power device degradation and/or catastrophic failure. Test procedures and data interpretation must consider the impact that heavy-ion induced off-state leakage current increases will have on subsequent single-event effect susceptibility and testability. On orbit, reliable performance in the presence of increased off-state leakage currents due to cumulative ion-induced non-catastrophic single-event effects must be assured over the mission lifetime. This work presents a large body of heavy-ion test data for different diode, power MOSFET, and JFET devices. Susceptibility to single-event effects is compared between SiC and Si power devices. Initial recommendations on heavy-ion radiation test methods for silicon carbide power devices are made and radiation hardness assurance is discussed with the goal of moving one step closer to reliably getting this technology off the ground into a broad array of spacecraft and instruments that will benefit from its unique capabilities.

diode↗

NASA Goddard Space Flight Center’s Recent Radiation Effects Test Results

Total ionizing dose, displacement damage dose, and single event effects testing were performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include FPGAs, optoelectronics, digital, analog, and bipolar devices.

Single-Event Effects (SEE)↗