Experimental comparison of time synchronization techniques by means of light signals and clock transport on the rotating earth

An experiment was conducted to investigate the equivalence of two methods of time transfer in a noninertial reference frame: by means of an electromagnetic signal using laser light pulses and by means of the slow ground transport of a hydrogen maser atomic clock. The experiment may also be interpreted as an investigation of whether the one-way speeds of light in the east-west and west-east directions on the rotating earth are the same. The light pulses were sent from a laser coupled to a telescope at the NASA Goddard Optical Research Facility (GORF) in Greenbelt, Maryland to the U.S. Naval Observatory (USNO) in Washington, DC. The optical path was made possible by a 30-cm flat mirror on a water tower near GORF and a 25-cm flat mirror on top of the Washington National Cathedral near USNO. The path length was 26.0 km with an east-west component of 20.7 km. The pulses were reflected back over the same path by a portable array of corner cube reflectors. The transmission and return times were measured with a stationary Sigma Tau hydrogen maser and a University of Maryland event timer at GORF, while the times of reflection were measured with a similar maser and event timer combination carefully transported to USNO. Both timekeeping systems were housed in highly insulated enclosures and were maintained at constant temperatures to within +/- 0.1 C by microprocessor controllers. The portable system was also protected from shock and vibration by pneumatic supports. The difference delta(T) between the directly measured time of reflection according to the portable clock and the time of reflection calculated from the light pulse signal times measured by the stationary clock was determined. For a typical trip delta(T) is less than 100 ps and the corresponding limit on an anisotropy of the one-way speed of light is delta(c/c) is less than 1.5 x 10(exp -6). This the only experiment to date in which two atomic clocks were calibrated at one location, one was slowly transported to the other end of a path, and the times of transmission, reflection, and return of short light pulses sent in different directions along the path were registered.

Nelson, R. A.

Plans to improve the experimental limit in the comparison of the east-west and west-east one-way light propagation times on the rotating earth

The preceding paper describes the results so far (interrupted in the Spring of 1989 because of lack of funds) of an experiment comparing the one-way light propagation times on the surface of the rotating Earth. For the 20 Km path length component in the East-West direction the predicted difference between the opposite sense propagation times would be 160 ps, if the approximately 360 Km/s surface speed of the Earth gives effective light speeds of 3 x 10(exp 8) m/s +/- 360 m/s. This could lead to a prediction of the difference between the clock transport and the light pulse synchronization methods described in the preceding paper: delta(T) = 0.5 (160) = 80 ps. The current upper bound of approximately 100 ps for delta(T) is limited by poorly understood systematic errors. The most important seems to be intensity-dependent time delays in the remote light pulse avalanche photo-diode detector. This will be replaced by a continuously operating circular scan streak camera having single photon sensitivity and a time resolution of approximately 5 ps. (This camera has recently been developed by the Xian Institute of Optics and Precision Mechanics in the P.R.C.). Better isolation from shocks and vibration for the Sigma-Tau hydrogen maser during transport will be provided. It is hoped that delta(T) is less than 20 ps can be achieved.

Alley, C. O.

High-accuracy global time and frequency transfer with a space-borne hydrogen maser clock

A proposed system for high-accuracy global time and frequency transfer using a hydrogen maser clock in a space vehicle is discussed. Direct frequency transfer with a accuracy of 10 to the minus 14th power and time transfer with an estimated accuracy of 1 nsec are provided by a 3-link microwave system. A short pulse laser system is included for subnanosecond time transfer and system calibration. The results of studies including operational aspects, error sources, data flow, system configuration, and implementation requirements for an initial demonstration experiment using the Space Shuttle are discussed.

Decher, R.

Time transfer between the Goddard Optical Research Facility and the U.S. Naval Observatory using 100 picosecond laser pulses

A horizontal two-way time comparison link in air between the University of Maryland laser ranging and time transfer equipment at the Goddard Optical Research Facility (GORF) 1.2 m telescope and the Time Services Division of the U.S. Naval Observatory (USNO) was established. Flat mirrors of 25 cm and 30 cm diameter respectively were placed on top of the Washington Cathedral and on a water tower at the Beltsville Agricultural Research Center. Two optical corner reflectors at the USNO reflect the laser pulses back to the GORF. Light pulses of 100 ps duration and an energy of several hundred microjoules are sent at the rate of 10 pulses per second. The detection at the USNO is by means of an RCA C30902E avalanche photodiode and the timing is accomplished by an HP 5370A computing counter and an HP 1000 computer with respect to a 10 pps pulse train from the Master Clock.

Alley, C. O.

Introduction to some fundamental concepts of general relativity and to their required use in some modern timekeeping systems

Einstein's theory of gravity as curved space-time is presented. Emphasis is on the physical concepts, using only elementary mathematics. For the slow motions and weak gravitational fields experienced on Earth, the main curvature is that of time, not space. Experiments demonstrating this property are reviewed. The fundamental effects of motion and gravitational potential on clocks in many practical situations are discussed.

Alley, C. O.

A space system for high-accuracy global time and frequency comparison of clocks

A Space Shuttle experiment in which a hydrogen maser clock on board the Space Shuttle will be compared with clocks on the ground using two-way microwave and short pulse laser signals is described. The accuracy goal for the experiment is 1 nsec or better for the time transfer and 10 to the minus 14th power for the frequency comparison. A direct frequency comparison of primary standards at the 10 to the minus 14th power accuracy level is a unique feature of the proposed system. Both time and frequency transfer will be accomplished by microwave transmission, while the laser signals provide calibration of the system as well as subnanosecond time transfer.

Decher, R.

Shuttle time and frequency transfer experiment

A proposed space shuttle experiment to demonstrate techniques for global high precision comparison of clocks and primary frequency standards is described. The experiment, using transmitted microwave and pulsed laser signals, compared a hydrogen maser clock onboard the space shuttle with a clock in a ground station in order to demonstrate time transfer with accuracies of 1 nsec or better and frequency comparison at the 10 to the -14th power accuracy level.

Allan, D. W.

Research on techniques for laser ranging to optical corner reflectors on the moon. Research on laser techniques and single photo-electron detection and timing

Experimental studies using a pulsed LED, Cerenkov source, and a 100 ps laser were made of various photomultipliers and discriminator combinations. In addition, a new type of neodymium-YAG frequency doubled laser was used as the basis for the development of a stable, short pulse, high repetition rate laser system. This laser was then used in conjunction with atomic clocks to study the effect of gravitational potential on elapsed time. Avenues to promote the development of international cooperation in the area of lunar laser ranging were also explored.

Alley, C. O.

New test of the equivalence principle from lunar laser ranging

An analysis of six years of lunar-laser-ranging data gives a zero amplitude for the Nordtvedt term in the earth-moon distance yielding the Nordtvedt parameter eta = 0.00 plus or minus 0.03. Thus, earth's gravitational self-energy contributes equally, plus or minus 3%, to its inertial mass and passive gravitational mass. At the 70% confidence level this result is only consistent with the Brans-Dicke theory for omega greater than 29. We obtain the absolute value of beta - 1 less than about 0.02 to 0.05 for five-parameter parametrized post-Newtonian theories of gravitation with energy-momentum conservation.

Williams, J. G.

Performance of the new Efratom optically pumped rubidium frequency standards and their possible application in space relativity experiments

The characteristics of Efratom optically pumped rubidium frequency standards are discussed. The Efratom units were compared with cesium beam and hydrogen maser standards and showed a stability of approximately 5 times 10 to the minus 12th power over two one-week periods. Dependency of frequency upon the environmental parameters of pressure, magnetic field, temperature, supply voltage, and acceleration was measured. A package of three units with automatic phase comparison and recording was designed and constructed to allow a measurement of relativistic effects on time with high accuracy during space missions.

Alley, C. O.

Laser ranging retroreflector

The lunar laser ranging retroreflector (LRRR) experiments to define the motion of the moon in its orbit are described, and the properties of the LRRR arrays and ground-station operation are discussed. It is concluded that primary benchmarks on the lunar surface are provided by the Apollo 11 and 14 arrays, and the placement of the Apollo 15 reflector.

Faller, J. E.

Geodesy results obtainable with lunar retroreflectors.

Retroreflector packages have been carried to the moon by the Apollo 11, Apollo 14, and Apollo 15 missions, as well as by Luna 17. Laser ranging from the earth onto these packages should eventually yield information on polar motions and crustal movements accurate to a few centimeters, and on UT1 to 100 microsec. Present (1971) error of the range measurements is 30 cm, but accuracy to 3 cm should be obtainable with improvements in methods and equipment.

Faller, J. E.

The lunar laser ranging experiment

With data from two or more well-located observing stations, the lunar range can be corrected accurately for the effects of polar motion and fluctuations in the earth's rotation rate. Very accurate corrections can be made for the earth tides at each station. It appears that the use of lasers giving roughly 0.1-msec pulse lengths is highly desirable. With them, single-shot ranging accuracies of about 3 cm are expected. The actual lunar range results will be analyzed by fitting a numerical integration for the lunar motion to the data. A mathematical model for lunar range is given. Tests of the theory of gravitation are considered.

Bender, P. L.

Laser ranging retroreflector

Laser ranging retroreflector deployed on lunar surface to study lunar librations for defining precisely lunar orbits and studying earth planetary structure - Apollo 14 flight

Alley, C. O.