Engineering PapersSearch

Engineering topics

Allen, R. E.

Publications and source records attributed to Allen, R. E..

Electrophoretic separation of human kidney cells at zero gravity

Electrophoretic isolation of cells results in a loss of resolution power caused by the sedimentation of the cells in the media. The results of an experiment to extract urokinase from human embryos during the Apollo Soyuz mission are presented and discussed.

Barlow, G. H.

Static free-fluid electrophoresis in space

The weightless environment onboard spacecraft in drifting flight has provided a unique opportunity to do experiments that cannot be done on the ground. High resolution free-fluid electrophoresis of particles proposed in the late 1960s to take advantage of reduced gravity began with brief experiments done during two Apollo flights. The recent Apollo Soyuz Test Project mission had two major experiments that accomplished the separation of viable biological cells. Experiments now are being planned for the Space Shuttle which will attempt to achieve high resolution of the separated species by using zone electrophoresis. These experiments will return a quantity sufficient for laboratory testing and establish the potential of fractionation and purification of biological materials in space.

Snyder, R. S.

Detailed results of ASTP experiment MA-011

This experiment was developed in order to conduct engineering and operational tests of electrokinetic equipment in a micro-gravity environment. The experimental hardware in general functioned as planned and electrophoretic separations were obtained in space. The results indicated the development of satisfactory sample collection, return, and preservation techniques. The application of a near-zero zeta potential interior wall coating to the experimental columns, confirmation of biocompatibility of all appropriate hardware components, and use of a sterile operating environment provided a significant step forward in the development of a biological processing facility in space. A separation of a test of aldehyde-fixed rabbit, human, and horse red blood cells was obtained. Human kidney cells were separated into several components and viable cells returned to earth. The isotachophoretic separation of red cells was also demonstrated. Problems associated with the hardware led to a lack of success in the attempt to separate subpopulations of human lymphocytes.

Seaman, G. V. F.

Electrophoresis technology experiment MA-011

Experiment MA-011, electrophoresis technology, was designed to test electrophoresis hardware that would continue the development of technology for electrophoretic separation of materials in the near zero g environment of space. The experimental hardware generally functioned as planned. Frozen live cells were successfully transported into space, electrophoretic processing was performed, and viable cells were returned to earth. A separation of the three types of fixed red blood cells (rabbit, human, and horse) was demonstrated. The human lymphocytes, however, showed no apparent migration. The separation of human kidney cells produced the most exciting data. Analysis shows electrophoretic separation throughout the entire column with at least four bands of viable cells. The isotachophoresis experiment definitely demonstrated the isotachophoretic separation of biological cells in a near zero g environment.

Allen, R. E.

Preparative electrophoresis of living lymphocytes

Vertical liquid columns containing low molecular weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of 0 gravity conditions. Another method that has been tested at 1 G, is the electrophoresis of lymphocytes in a upward direction in vertical columns. By both methods up to 10 to the 7th power lymphocytes can be separated at one time in a 30 cm glass column of 8 mm inside diameter, at 12 v/cm, in 2 hours. Due to convection and sedimentation problems, the separation at 1 G is less than ideal, but it is expected that at 0 gravity electrophoresis will prove to be a uniquely powerful cell separation tool. The technical feasibility of electrophoresing inert particles at 0 G has been proven earlier, during the flight of Apollo 16.

Vanoss, C. J.

Preparative liquid column electrophoresis of T and B lymphocytes at gravity = 1

Vertical liquid columns containing low-molecular-weight dextran density gradients can be used for preparative lymphocyte electrophoresis on earth, in simulation of zero gravity conditions. Another method that has been tested at 1 g, is the electrophoresis of lymphocytes in an upward direction in vertical columns. By both methods up to 100 million lymphocytes can be separated at one time in a 30-cm glass column of 8-mm inside diameter, at 12 V/cm, in two hours. Due to convection and sedimentation problems, the separation at 1 g is less than ideal, but it is expected that at zero gravity electrophoresis will probe to be a uniquely powerful cell separation tool.

Van Oss, C. J.

Effect of vertical active vibration isolation on tracking performance and on ride qualities

An investigation to determine the effect on pilot performance and comfort of an active vibration isolation system for a commercial transport pilot seat is reported. The test setup consisted of: a hydraulic shaker which produced random vertical vibration inputs; the active vibration isolation system; the pilot seat; the pilot control wheel and column; the side-arm controller; and a two-axis compensatory tracking task. The effects of various degrees of pilot isolation on short-term (two-minute) tracking performance and comfort were determined.

Dimasi, F. P.

Design, fabrication and testing of two electrohydraulic vibration isolation systems for helicopter environments

Two electrohydraulic vibration isolation systems were designed and fabricated to reduce the vertical vibrations transmitted to the XH-51N research helicopter cabin at the blade passage frequency (18 Hz) and its first harmonic (36 Hz). Hydraulic power and electrical control are provided to two separate servoactuators from a common power supply and control electronics package located behind the pilot's seat. One servoactuator is installed between the cabin and fuselage and replaces an existing passive spring. A second servoactuator is mounted between the existing seat and cabin floor. Both servoactuators incorporate a mechanical failsafe design. The control electronics circuitry provides automatic tracking of the blade passage frequency. Results of laboratory, environmental and ground vibration tests employing an XH-51A stripped down helicopter fuselage show that the active cabin isolator reduces the vertical vibrations transmitted from the fuselage attachment point to the cabin attachment point at 18 and 36 Hz (or as an alternative, 6 Hz) by better than 90 percent.

Allen, R. E.