Reproducible benchmark for the SNAP 8 experimental reactor at operating conditions
This work presents fully reproducible multiphysics benchmark models of the Systems for Nuclear Auxiliary Power (SNAP) 8 Experimental Reactor at operating conditions with coolant flow. Wet experiment (with coolant, at power) validation benchmarks are presented using both deterministic (Serpent-Griffin) and Monte-Carlo (OpenMC-Cardinal) multiphysics frameworks coupled with thermal-hydraulic solvers in MOOSE. Reactivity coefficient measurements including fuel temperature, isothermal temperature, and power coefficients show good agreement with experiments, with discrepancies within experimental uncertainty. Reactivity worth experiments for coolant, samarium, and xenon poisoning are reproduced with differences under 200 pcm. Comparison between Serpent-Griffin and OpenMC-Cardinal frameworks reveal multiphysics coupling introduces positive reactivity effects (100-200 pcm) compared to uniform temperature and density fields at nominal operating conditions. Comparison between Serpent-Griffin and reference Serpent solution shows that power distributions maintain consistent radial and axial peaking behavior. All models, assumptions, thermophysical and thermomechanical properties, and material definitions are thoroughly documented with cited references; model inputs and model generating scripts are stored in the snapReactors GitHub repository.