Engineering Papers⌕ Search

Engineering topics

Alekseev, I.

Publications and source records attributed to Alekseev, I..

148 records · Page 9

Run-08 pC polarization analysis

In this note we will discuss the analysis of RHIC run 08 pC data that were collected during February 14 - March 10, 2008. An analysis method that is similar to Run 05 and Run 06 was adopted for Run 08 analysis (except few minor changes, which are described below). A detailed analysis note and a NIM article that describe the pC analysis procedure (for run 05 and run 06) can be found elsewhere [1]. In brief, the analysis consists of calibrating the detectors, determining energy corrections (“dead layers”), determining good runs and extracting the polarization from data. Next few sections describe these steps more in detail.

43 PARTICLE ACCELERATORS↗

Experimental results of hydrogen distillation at the low power cryogenic column for the production of deuterium depleted hydrogen

The Deuterium Removal Unit (DRU) has been designed and built at the Petersburg Nuclear Physics Inst. (PNPI) to produce isotopically pure hydrogen with deuterium content less than 1 ppm. The cryogenic distillation column of 2.2 cm inner diameter and 155 cm packing height is the main element of the DRU. Column performances at different hydrogen distillation operating modes have been measured. The height equivalent to theoretical plate (HETP) for the column is 2.2 cm and almost constant over a wide range of vapour flow rates. Deuterium depleted hydrogen with a deuterium content of less than 0.1 ppm was produced in required quantity. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Water-hydrogen isotope exchange process analysis

The use of a numerical method is needed to find a solution to the equation system describing a general case of heterogeneous isotope exchange between gaseous hydrogen and liquid water in a column. A computer model of the column merely outputting the isotope compositions in the flows leaving the column, like the experimental column itself, is a 'black box' to a certain extent: the solution is not transparent and occasionally not fully comprehended. The approximate analytical solution was derived from the ZXY-diagram (McCabe-Thiele diagram), which illustrates the solution of the renewed computer model called 'EVIO-4.2' Several 'unusual' results and dependences have been analyzed and explained. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Run05 Proton Beam Polarization Measurements by pC-Polarimeter (V.1.1)

The polarization of the proton beams at the Relativistic Heavy Ion Collider (RHIC)[3] is measured using both an atomic beam source hydrogen gas jet (H-Jet)[4, 5] and protoncarbon (pC) polarimeters. These polarimeters are set up in the 12 o’clock area in the RHIC ring. The H-Jet polarimeter is located at the collision point allowing measurements of both beams. Two identical pC-polarimeters are equipped in the yellow and blue rings, where the rings are separated. The pC-polarimeter measures relative polarization to a few percent statistical accuracy within 20 to 30 seconds using an ultra-thin (typically 6 ~ 8 µg/cm 2 ) carbon ribbon target, providing fast feedback to beam operations and experiments. The absolute normalization is provided by the hydrogen polarimeter, which measures over 1 ~ 2 days to obtain ~5% statistical uncertainty (in Run05). Thus, the operation of the carbon polarimeters was focused on better control of relative stability between one measurement to another measurement rather than measuring the absolute polarization.

43 PARTICLE ACCELERATORS↗