Pyrotechnic shock measurement and data analysis requirements

An investigation is described into the laboratory measurement and analysis of pyrotechnic shock which was prompted at JPL when two separate facilities generated discrepant pyrotechnic shock data while testing Mariner Jupiter/Saturn 1977 spacecraft hardware. Both of the testing facilities were surveyed. The only difference noted was in the FM tape recorders used to record the data. One facility used a tape recorder operating at 60 in./sec with a frequency response of 20 kHz; the other used a tape recorder operating at 120 in./sec with a frequency response of 80 kHz. The accelerometers, cables, charge amplifiers, and mechanical setups were identical.

Albers, L.

Pyrotechnic shock measurement and data analysis requirements

A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.

Albers, L.

Miniature pyrotechnic shock simulator

The development of pyrotechnic shock testing is prompted by requirements created by pyrotechnic devices. At the present time there are no standard techniques for the production of a given pulse. At the Jet Propulsion Laboratory a device has been developed which appears to be promising as a general-purpose laboratory tool. This paper concerns the development of that device.

Milder, G.

Pyrotechnic shock measurement and data analysis requirements

An investigation of laboratory measurement and analysis of pyrotechnic shock is described which was prompted when two separate facilities produced discrepant pyrotechnic-shock data while testing Mariner Jupiter/Saturn 1977 spacecraft hardware. Both testing facilities are thoroughly examined to find a possible cause for the discrepancies, and it is noted that one facility incorporated an FM tape recorder operating at 60 in./sec with a frequency response of 20 kHz while the other incorporated a tape recorder operating at 120 in./sec with a frequency response of 80 kHz. It is found that the discrepancies were a direct result of the inadequate recording frequency response of the tape recorders. Other factors involved in obtaining more accurate data are discussed.

Albers, L.