Assessment of SNPP VIIRS RSB detector-to-detector differences using deep convective clouds and deserts

An accurate on-orbit characterization of the Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the Suomi National Polar-orbiting Partnership satellite is essential to satisfy the requirements from NOAA, NASA, and the general research community for high-quality operational and research products. NASA’s Land Science Investigator-led Processing System (LSIPS) sensor data records (SDRs) are utilized to assess the stability of the calibrated top of atmosphere reflectance over the deep convective clouds (DCCs) and over the Libya-4desert site. The results from DCCs and desert show detector-to-detector (D2D) reflectance differences in the VIIRS reflective solar bands, 10 moderate-resolution bands (M-bands, M1to M5, M7 to M11), and three imagery resolution bands (I-bands, I1-I3). More importantly, the D2D differences exhibit an increase in magnitude over time for bands M1 to M5 and I1to I2, which induces noticeable striping and higher uncertainties in the downstream data products. The largest D2D difference is observed in bands M1 and M2, with magnitudes greater than1.8% in trends among the 16 detectors and standard deviations less than 0.12% over time. TheD2D stability assessment results over DCCs are consistent with those observed over the Libya-4desert site. To improve the quality of the calibrated SDR reflectance data, NASA’s VIIRS characterization support team has improved the calibration algorithm to incorporate corrections based on these DCC measurements to mitigate the striping (detector differences) observed in the current version of the SDR. These improvements are planned to be included in the next mission reprocessing of the LSIPS land products.

SNPP VIIRS↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Response Versus Scan-Angle Assessment of MODIS Reflective Solar Bands in Collection 6.1 Calibration

The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Aqua and Terra satellites have been operated for nearly two decades, producing high-quality earth observation data sets suitable for a broad range of scientific studies regarding the earth’s land, ocean, and atmospheric processes. The high radiometric accuracy of MODIS reflective solar band (RSB) calibration has also served as benchmark measurements for on-orbit cross-calibration studies. As the two MODIS instruments have operated well beyond their design lifespan of six years, the measurements from the onboard calibrators alone become inadequate to characterize the sensor’s response at all scan angles, as evinced by long-term drifts observed at certain scan positions of the Aqua-MODIS 0.64- and 0.86-μm bands in Collection 6 (C6) data set. The latest MODIS Level 1B C6.1 data set incorporates earth-view response trending from invariant desert sites as supplemental inputs to characterize the scan-angle calibration dependencies for all RSB. This article presents a deep convective cloud (DCC)-based calibration approach for an independent evaluation of the MODIS RSB response versus scan-angle (RVS) performance in C6.1. The long-term calibration stability and RVS differences in C6.1 have been significantly improved for Aqua-MODIS RSB. The observed RVS differences of more than 2% in Aqua-MODIS C6 bands 1 and 2 have been reduced to within 1% in C6.1. Some RSBs of Terra-MODIS have suffered temporal drifts up to ~2% and calibration shifts up to 3%, particularly around 2016 when the Terra satellite entered into safe mode. The DCC approach has been found very effective in tracking the on-orbit RVS changes over time.

Clouds and the Earth’s Radiant Energy System (CERE↗

Assessment of VIIRS on-orbit polarization sensitivity and its impact on CLARREO pathfinder inter-calibration

The primary objective of the CLARREO Pathfinder (CPF) mission is to demonstrate essential measurement technologies to enable highly accurate decadal change observations traceable on-orbit to SI standards. Another important objective of the CPF is to demonstrate inter-calibration with the VIIRS sensor and to show that such high-accuracy reference inter-calibration is achievable. To satisfy this requirement, it is important to understand and quantify uncertainties in VIIRS sensor measurements. Based on prelaunch test results, the reflective solar bands of both SNPP and NOAA-20 VIIRS have exhibited polarization sensitivities in the shortest wavelength bands, with an unexpectedly larger sensitivity observed for NOAA-20 VIIRS, particularly in bands M1 to M4. In this study, we use VIIRS Level-1B reflectance data collected over the Pseudo-Invariant Calibration Sites over North African desert region to examine the polarization associated uncertainty for these four bands. Impact due to BRDF on the reflectance data is considered by comparing baseline results obtained from the same viewing and solar zenith angles under relatively low polarization sensitivity. Impact due to detector relative difference in polarization sensitivity is examined by normalizing reflectances by the value of the middle detector. Results of this study provide useful information on VIIRS uncertainty contribution due to polarization when conducting CPF and VIIRS inter-calibration.

VIIRS↗

Terra MODIS: 20 years of on-orbit calibration and performance

For nearly 20 years, Terra MODIS observations have generated a broad range of data products, enabling the remote sensing community and users worldwide for their studies of many key geophysical parameters of the Earth’s system. MODIS collects data in 36 spectral bands, covering wavelengths from 0.41 to 14.4 μm, that are calibrated by a set of on-board calibrators (OBC). Also contributed to sensor on-orbit calibration and characterization are near monthly-scheduled lunar observations and long-term trends of sensor responses over select ground targets. The quality of MODIS data products relies strongly on the dedicated efforts to the operate instrument, derive and update calibration parameters, and improve calibration strategies and algorithms in order to address on-orbit changes of sensor characteristics and its OBC functions. This paper provides an overview of Terra MODIS on-orbit operation and calibration activities over the last 20 years, including changes made to extend and preserve instrument and OBC functions and their implementation strategies. It illustrates sensor on-orbit performance using data from its OBC, lunar observations, and select ground targets and discusses major changes in sensor characteristics and corrections applied to the L1B algorithms or updates of calibration look-up tables (LUTs). Also described in this paper are lessons learned from Terra MODIS and future efforts to further extend its long-term data records.

Terra↗

Intercalibration of the reflective solar bands of MODIS and MISR instruments on the Terra platform

The multispectral imaging sensors on the Terra platform have been operating for over two decades facilitating a variety of scientific applications. The MODIS sensor provides the largest spectral coverage of 0.41 to 14.2 μm, acquiring data at three different spatial resolutions, 250 m, 500 m, and 1 km. The MISR instrument views the Earth using nine discrete cameras pointed at fixed angles including viewing the nadir direction at a spatial resolution of 275 m and covering a wavelength range from 0.44 to 0.86 μm. Being on the same platform, the two sensors complement each other in terms of spatial coverage (and target viewing geometry) and facilitate synergistic applications using multispectral data. A consistent radiometric calibration between these sensors is a prerequisite for creating high quality science products from their observations. Both instruments underwent intensive prelaunch characterization, with calibration monitored on-orbit using their onboard calibrators. In this paper, we perform a calibration inter-comparison of the spectrally matching bands of the two instruments using vicarious techniques. Vicarious techniques include multiyear simultaneous views of the North African desert, North Atlantic Ocean and Dome Concordia, thereby covering the different parts of the dynamic range. Also included in this work are the near-simultaneous top-of-atmosphere (TOA) reflectance measurements from Railroad Valley, USA, as provided by the RadCalNet (converted to TOA), that are used as a calibration reference to compare the on-orbit observations between MODIS and MISR.

Intercalibration↗

Performance Assessment of the NOAA-20 VIIRS RSB Using Deep Convective Clouds

The Visible Infrared Imaging Radiometer Suite (VIIRS) onboard the NOAA-20 (N20) satellite was launched on November 18, 2017. The N20 VIIRS reflective solar bands (RSBs) are calibrated on-orbit using a solar diffuser. An accurate on-orbit calibration is crucial to the high-quality downstream products facilitating atmosphere, ocean and land applications. In this study, the stability of the Level 1B (L1B) reflectance product is investigated using measurements over deep convective clouds (DCCs) for M-bands M1-M5, M7-M11, and I-bands I1-I3. The methodologies developed previously for Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS) sensors and Suomi National Polar-orbiting Partnership (SNPP) VIIRS are extended and applied to the N20 RSB to derive DCC-based trends. The Collection 2 L1B data produced by NASA Land Science Investigator-led Processing Systems (SIPS) is used to evaluate the performance of the N20 VIIRS RSB calibration. At nadir, the reflectance trends for M1, M5, M8-M11, and I3 are insignificant compared to their corresponding variations (STDs) except for bands M2-M4, M7, and I1-I2, whose trends are larger than or equivalent to their STDs. The reflectance is relatively stable compared to their STDs for all the study RSBs at six aggregation zones across the entire scan angle range. Also discussed in this paper are the detector-to-detector differences and half-angle mirror side differences using the DCCs. Future applications using DCCs, which include an intercomparison with SNPP VIIRS, are also discussed.

N20 VIIRS↗