Engineering Papers⌕ Search

Engineering topics

Ahn, H.

Publications and source records attributed to Ahn, H..

Temperature Effects in the ATIC BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment contains a segmented calorimeter composed of 320 individual BGO crystals (18 radiation lengths deep) to determine the particle energy. Like all inorganic scintillation crystals the light output of BGO depends not only on the energy deposited by particles but also on the temperature of the crystal. ATIC had successful flights in 2000/2001 and 2002/2003 from McMurdo, Antarctica. The temperature of balloon instruments varies during their flights at altitude due to sun angle variations and differences in albedo from the ground and is monitored and recorded. In order to determine the temperature sensitivity of the ATIC calorimeter it was temperature cycled in the thermal vacuum chamber at the CSBF in Palestine, TX. The temperature dependence is derived from the pulse height response to cosmic ray muons at various temperatures.

Isbert, J.↗

Preliminary Results From the First Flight of ATIC

The Advanced Thin Ionization Calorimeter (ATIC) instrument is designed to measure the composition C and energy spectra of Z = 1 to 28 cosmic rays over the energy range approximately 10 GeV - 100 TeV. The instrument was calibrated in September 1999 at CERN using accelerated electron, proton and pion beams. ATIC was launched as a long duration balloon test flight on 12/28/00 local time from McMurdo, Antarctica. After flying successfully for about 16 days the payload was recovered in excellent condition. Absolute calibration of the detector response was made using cosmic-ray muons. The data analysis algorithm which was developed with Monte Carlo simulations and validated with the CERN beam test will be used for the flight data analysis. Preliminary results of the protons and C helium spectra will be reported in this paper.

Seo, E. S.↗

The ATIC Experiment: Performance of the Scintillator Hodoscopes and the BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its first flight from Mcmurdo, Antarctica 28/12/2000 to 13/01/2001, local time, recording over 360 hours of data. The design goal of ATIC was to measure the Cosmic Ray composition and energy spectra from approximately 50 GeV to near 100 TeV utilizing a Si-matrix detector, a scintillator hodoscope, carbon targets and a calorimeter consisting of a stack of BGO scintillator crystals. The design, the operations and in-flight performance of the scintillator hodoscope and the BGO calorimeter are described.

Isbert, Joachim↗

The First Flight of ATIC: Preliminary Results on Li, Be, B Nuclei

The ATIC (Advanced Thin Ionization Calorimeter) balloon experiment had its first test flight which lasted for 16 days and brought it around Antarctica. The ATIC spectrometer consists of a fully active BGO (Bismuth Germanate) calorimeter, scintillator hodoscopes and a silicon matrix. The silicon matrix consisted of 4480 pixels was used as a charge detector in the experiment. We discuss a possibility of the ATIC to measure individual energy spectra of Li, Be and B.

Zatsepin, V. I.↗

The ATIC Experiment: First Balloon Flight

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment had its maiden test flight from McMurdo, Antarctica 28/12/00 to 13/01/01, local time, recording over 360 hours of data. ATIC was designed to measure the composition and energy spectra of cosmic rays from approx. 10 GeV to near 100 TeV utilizing a Si matrix detector to determine charge in conjunction with a scintillator hodoscope which measures charge and trajectory. Cosmic rays that interact in a carbon target have their energy determined from the shower that develops within a fully active calorimeter composed of a stack of scintillating BGO (Bismuth Germanate) crystals. ATIC's geometry factor is about 0.25 sq. m -sr. During line-of-sight operations much of the datastream was transmitted to the ground. For most of the flight, the data was recorded on-board, yielding 45 GB of flight data for analysis. The payload construction, operations and in-flight performance are described, along with preliminary results from the on-going analysis.

Wefel, J. P.↗

High Energy Electron Detection with ATIC

The ATIC (Advanced Thin Ionization Calorimeter) balloon-borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons. The instrument was exposed to high-energy beams at CERN H2 bean-dine in September of 1999. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well.

Chang, J.↗

The CNO Concentration in Cosmic Ray Spectrum as Measured From The Advanced Thin Ionization Calorimeter Experiment

We present preliminary results on the spectra of CNO nuclei in the cosmic radiation as measured in the first flight of the Advanced Thin Ionization Calorimeter Balloon Experiment (ATIC) which lasted for 16 days, starting in December, 2000 with a launch from McMurdo, Antarctica. ATIC is a multiple, long duration balloon flight, investigation for the study of cosmic ray spectra from below 50 GeV to near 100 TeV total energy, using a fully active Bismuth Germanate (BGO) calorimeter. It is equipped with the first large area mosaic of small fully depleted silicon detector pads capable of charge identification in cosmic rays from H to Fe. As a redundancy check for the charge identification and a coarse particle tracking system, three projective layers of x-y scintillator hodoscopes were employed, above, in the center and below a Carbon interaction "target".

Fazely, A. R.↗