Engineering Papers⌕ Search

Engineering topics

Adolphsen, Chris

Publications and source records attributed to Adolphsen, Chris.

39 records · Page 3

FLASH Beam-Off RF Measurements and Analyses

The FLASH L-band (1.3 GHz) superconducting accelerator facility at DESY has a Low Level RF (LLRF) system that is similar to that envisioned for ILC. This system has extensive monitoring capability and was used to gather performance data relevant to ILC. In particular, waveform data were recorded with beam off for three, 8-cavity cryomodules to evaluate the input rf stability, perturbations to the SC cavity frequencies and the rf overhead required to achieve constant gradient during the 800-s pulses. In this paper, we discuss the measurements and data analysis procedures and present key findings on the pulse-to-pulse input rf and cavity field stability.

43 PARTICLE ACCELERATORS↗

Performance of a 1.3 GHZ Normal-Conducting 5-Cell Standing-Wave Cavity

A 5-cell, normal-conducting, 1.3 GHz, standing-wave (SW) cavity was built as a prototype capture accelerator for the ILC positron source. Although the ILC uses predominantly superconducting cavities, the capture cavity location in both a high radiation environment and a solenoidal magnetic field requires it to be normal conducting. With the relatively high duty ILC beam pulses (1 msec at 5 Hz) and the high gradient required for efficient positron capture (15 MV/m), achieving adequate cavity cooling to prevent significant detuning is challenging. This paper presents the operational performance of this cavity including the processing history, characteristics of the breakdown events and the acceleration gradient witnessed by a single bunch at different injection times for different rf pulse lengths.

43 PARTICLE ACCELERATORS↗

Progress in L-Band Power Distribution System R&D at SLAC

We report on the L-band RF power distribution system (PDS) developed at SLAC for Fermilab's NML superconducting test accelerator facility. The makeup of the system, which allows tailoring of the power distribution to cavities by pairs, is briefly described. Cold test measurements of the system and the results of high power processing are presented. We also investigate the feasibility of eliminating the expensive, lossy circulators from the PDS by pair-feeding cavities through custom 3-dB hybrids. A computational model is used to simulate the impact on cavity field stability due to the reduced cavity-to-cavity isolation.

43 PARTICLE ACCELERATORS↗