Engineering Papers⌕ Search

Engineering topics

Added, Nemitala

Publications and source records attributed to Added, Nemitala.

High sensitivity boron quantification in bulk silicon using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction

There is a great need to quantify sub-ppm levels of boron in bulk silicon. There are several methods to analyze B in Si: Nuclear Reaction Analysis using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be reaction exhibits a quantification limit of some hundreds ppm of B in Si. Heavy Ion Elastic Recoil Detection Analysis offers a detection limit of 5 to 10 at. ppm. Secondary Ion Mass Spectrometry is the method of choice of the semiconductor industry for the analysis of B in Si. This work verifies the use of NRA to quantify B in Si, and the corresponding detection limits. Proton beam with 1.6 up to 2.6 MeV was used to obtain the cross-section of the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction at 170 Degree-Sign scattering angle. The results show good agreementwith literature indicating that the quantification of boron in silicon can be achieved at 100 ppm level (high sensitivity) at LAMFI-IFUSP with about 16% uncertainty. Increasing the detection solid angle and the collected beam charge, can reduce the detection limit to less than 100 ppm meeting present technological needs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automatic energy calibration algorithm for an RBS setup

This work describes a computer algorithm for automatic extraction of the energy calibration parameters from a Rutherford Back-Scattering Spectroscopy (RBS) spectrum. Parameters like the electronic gain, electronic offset and detection resolution (FWHM) of a RBS setup are usually determined using a standard sample. In our case, the standard sample comprises of a multi-elemental thin film made of a mixture of Ti-Al-Ta that is analyzed at the beginning of each run at defined beam energy. A computer program has been developed to extract automatically the calibration parameters from the spectrum of the standard sample. The code evaluates the first derivative of the energy spectrum, locates the trailing edges of the Al, Ti and Ta peaks and fits a first order polynomial for the energy-channel relation. The detection resolution is determined fitting the convolution of a pre-calculated theoretical spectrum. To test the code, data of two years have been analyzed and the results compared with the manual calculations done previously, obtaining good agreement.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A PIXE Study of Trace Elements in Sediments of Toledo River, Parana, Brazil

In this work we characterize sediment samples from several points in the River Toledo--PR, using the PIXE (Particle Induced X-Ray Emission) spectroscopy technique, in order to quantify trace elements in these samples aiming to provide information about pollution levels for trace elements. The samples were collected in six points of river, during a period of twelve months (12/2001 to 11/2002). The collected material was air-dried at room temperature and then pressed in pellets. The samples were irradiated under vacuum using a H beam of 2,39 MeV in the LAMFI (Laboratorio de Analises de Materials por Feixe Ionico). Produced x-rays were detected using a Si(Li) detector and a standard electronics. Using the Axil program to analyze PIXE spectra it was possible to identify and quantify some elements present in the samples. A multi-elemental referenced material (Buffalo River sediment--RM 8704) was used to validate the PIXE analysis with thick targets. Twelve months of monitoring of six river points were analyzed and these allowed us to identify 18 elements such as Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Zr e Pb. The following elements were monitored: V, Cr, Mn, Co, Ni, Cu, Zn e Pb.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗