Engineering Papers⌕ Search

Engineering topics

Adam, J

Publications and source records attributed to Adam, J.

The ALICE Transition Radiation Detector: Construction, operation, and performance

The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this article, the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.

43 PARTICLE ACCELERATORS↗

SU-E-QI-13: Predictable Models for Radio-Sensitizing Agent Kinetics: Application to Stereotactic Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The radiation dose enhancement depends on the time course of iodine in the tumors. A prolonged CT scanning (∼30 min) is required to follow-up iodine kinetics for recruited patients. This protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce the acquisition time. Methods: 12 patients received an intravenous bolus of iodinated contrast agent, followed by a steady-state infusion to ensure stable intra-tumoral amounts of iodine during the treatment. Absolute iodine concentrations (IC) were derived from 40 multi-slice dynamic conventional CT images of the brain. The impulse response function (IRF) to the bolus was estimated using the adiabatic approximation of the Johnson and Wilson's model. The arterial input function (AIF) of the steady-state infusion was fitted with several models: Gamma, Gamma with recirculation and hybrid. Estimated IC were calculated by convolving the IRF with the modeled AIF and were compared to the measured data. Results: The gamma variate function was not relevant to model the AIF due to high differences with the measured AIF. The hybrid and the gamma with recirculation models provided differences below 8% during the whole acquisition time. The absolute difference between the measured and the estimated IC was lower than 0.5 mg/ml, which corresponds to 5% of dose enhancement error. Conclusion: The proposed method allows a good estimation of the iodine time course with reduced scanning delays (3 instead of 30 min) and dose to the patient. The results suggest that the dose errors may stay within the radiotherapy standards.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

SU-E-T-56: Brain Metastasis Treatment Plans for Contrast-Enhanced Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The aim of this study is to compare dynamic stereotactic arc-therapy and iodineenhanced SSRT. Methods: Five patients bearing brain metastasis received a standard helical 3D-scan without iodine. A second scan was acquired 13 min after an 80 g iodine infusion. Two SSRT treatment plans (with/without iodine) were performed for each patient using a dedicated Monte Carlo (MC) treatment planning system (TPS) based on the ISOgray TPS. Ten coplanar beams (6×6 cm2, shaped with collimator) were simulated. MC statistical error objective was less than 5% in the 50% isodose. The dynamic arc-therapy plan was achieved on the Iplan Brainlab TPS. The treatment plan validation criteria were fixed such that 100% of the prescribed dose is delivered at the beam isocentre and the 70% isodose contains the whole target volume. The comparison elements were the 70% isodose volume, the average and maximum doses delivered to organs at risk (OAR): brainstem, optical nerves, chiasma, eyes, skull bone and healthy brain parenchyma. Results: The stereotactic dynamic arc-therapy remains the best technique in terms of dose conformation. Iodine-enhanced SSRT presents similar performances to dynamic arc-therapy with increased brainstem and brain parenchyma sparing. One disadvantage of SSRT is the high dose to the skull bone. Iodine accumulation in metastasis may increase the dose by 20–30%, allowing a normal tissue sparing effect at constant prescribed dose. Treatment without any iodine enhancement (medium-energy stereotactic radiotherapy) is not relevant with degraded HDVs (brain, parenchyma and skull bone) comparing to stereotactic dynamic arc-therapy. Conclusion: Iodine-enhanced SSRT exhibits a good potential for brain metastasis treatment regarding the dose distribution and OAR criteria.

60 APPLIED LIFE SCIENCES↗

Interaction of {sup 12}C ions with nuclei of enriched tin isotopes at an energy of 2.2 GeV per nucleon

The formation cross sections for about 110 products of interaction between a {sup 12}C ion beam of energy 2.2 GeV per nucleon and tin targets from the isotopes {sup 112,118,120,124}Sn were calculated. Massyield and charge distributions were obtained for {sup 112,118,124}Sn targets. An analysis of these charge distributions reveals that the positions of their maxima, Z{sub p}, are different for targets having different nucleon compositions. The formation cross sections for neutron-rich products originating from neutron-rich targets are found to increase in all product-mass regions considered in our study. Mass distributions are compared for proton-, deuteron- and ion-nucleus reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Formation of close-to-target products in reactions induced by {sup 12}C ions on tin isotopes at the energy of 2.2 GeV per nucleon

Cross sections for charge-exchange reactions induced by the interaction between {sup 12}C ions of energy E{sub 12{sub C}} = 2.2 GeV per nucleon and tin targets enriched in the isotopes {sup 118,120,124}Sn were measured by the induced-activity method. The cross sections for products whose charge numbers were in excess of the target charge number (Sb and Te) were determined. The shape of the isotope distribution of Sb products was indicative of the evaporative character of neutron emission in the formation of final-state products. The dependence of cross sections for charge-exchange reactions on the nucleonic composition of the target was considered. The contribution of electromagnetic excitation to the cross section for the reaction {sup 124}Sn({sup 12}C, x){sup 124}Sn was estimated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systematization of cross sections for the production of residual nuclei on separated tin isotopes in reactions induced by various-energy protons

Cross sections for the production of residual nuclei on the isotopes {sup 112,118,120,124}Sn irradiated with 0.66-, 1.0-, 3.65-, and 8.1-GeV proton beams were investigated. A ten-parameter semiempirical formula was used to systematize the cross sections in question. A comparative analysis of parameter values obtained at different proton energies was performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Symmetric and asymmetric fission modes in proton-induced fission at 660 MeV of {sup 238}U

Fission product cross sections of intermediate-energy fission of {sup 238}U were used in order to construct the charge and mass yield distributions. Enriched target of {sup 238}U was irradiated by proton beam with energy 660 MeV for several hours at the LNP Phasotron, Joint Institute for Nuclear Research (JINR), Dubna, Russia. The charge distribution of the fission fragments was analyzed for calculation of isobaric cross sections. The mass yield curves were expanded into symmetric and asymmetric components according multimodal fission approach. The fissility values of actinides were calculated at given proton energy. The obtained results have been compared to the same data for targets {sup 237}Np and {sup 241}Am.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recoil studies in the reaction of {sup 12}C ions with the enriched isotope {sup 118}Sn

The recoil properties of the product nuclei from the interaction of 2.2 GeV/nucleon {sup 12}C ions from Nuclotron of the Laboratory of High Energies, Joint Institute for Nuclear Research at Dubna with a {sup 118}Sn target have been studied via catcher foils method. The experimental data were analyzed using the mathematical formalism of the standard two-step vector model. The results for {sup 12}C ions are compared with those for deuterons and protons. Three different Los Alamos versions of the Quark-Gluon String Model were used for comparison with our experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ferroelectric characterization of nondensified particle-based structures

Increasing requirements concerning the powder quality for fine-grained ferroelectric ceramics or for low temperature coating technologies provoke further improvements in particle characterization methods. So far, a correct quantitative measurement of the ferroelectric properties for as synthesized particles is lacking and only already sintered ceramics can be measured precisely. We report on a measurement setup to characterize films made of as synthesized ferroelectric particles. The chosen measurement setup enables the definite determination of ferroelectricity in such nondensified particle-based structures. A centrifugally casted BaTiO{sub 3} particulate film with 50% porosity is used for characterization. The correct value of the remanent polarization for this porous film obtained by the new method is almost half the value estimated by conventional measurement setups. Compared to a sintered BaTiO{sub 3} ceramic the achieved remanent polarization is much lower (10%). At the same time a higher maximum field has to be applied to the sample as lower fields act on the individual particles because of the porosity of this film.

36 MATERIALS SCIENCE↗

Multimode approach to {sup 241}Am and {sup 237}Np fission induced by 660-MeV protons

The results obtained by measuring cross sections for the formation of fragments originating from {sup 241}Am and {sup 237}Np fission induced by 660-MeV protons are presented. The charge and mass distributions of fragments are analyzed within the multimode-fission model, symmetric and asymmetric fission channels being separated. The contributions of various fission components are estimated, and the fission cross sections for the {sup 241}Am and {sup 237}Np nuclei are calculated along with the fissilities of these nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recoil products from p+{sup 118}Sn and d+{sup 118}Sn at 3.65 GeV/A

The recoil properties of the product nuclei from the interaction of 3.65-GeV/nucleon protons and deuterons from the Nuclotron and Synchrophasotron of the Laboratory of High Energies (LHE), Joint Institute for Nuclear Research (JINR) at Dubna, with a {sup 118}Sn target have been studied using catcher foils. The experimental data were analyzed using the mathematical formalism of the standard two-step vector model. The analysis of kinematical characteristics of the light and medium-mass reaction products confirmed the contribution of fragmentation (or multifragmentation) processes in the production of these nuclei. The comparison of the results for protons and deuterons was made. The longitudinal momenta transferred to the target in the interaction with protons and deuterons were similar and was shown to depend only on the velocity, but not on the mass of projectile. Three different Los Alamos versions of the quark-gluon-string model (LAQGSM) were used for the discussion of our experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗